PubMed Health⌕ Search

Biomedical subjects

Joop de Vries

Publications and source records attributed to Joop de Vries.

10 recordsLinked to original sources

Biofilm formation on surface characterized micro-implants for skeletal anchorage in orthodontics.

Micro-implants are increasingly popular in clinical orthodontics to effect skeletal anchorage. However, biofilm formation on their surfaces and subsequent infection of peri-implant tissues can result in either exfoliation or surgical removal of these devices. The present study aimed to assess biofilm formation on five commercially available, surface characterized micro-implant systems in vitro. The elemental surface compositions of as-received and autoclave-sterilized micro-implants were characterized by X-ray photoelectron spectroscopy. High carbon contamination was detected on the oxide surfaces, along with traces of inorganic elements (Ca, Cu, Cr, Pb, Zn, and P) which disappeared after Ar(+) ion sputtering. The mean surface roughnesses (R(a)) were around 182nm for titanium micro-implants, and 69nm for stainless steel micro-implants, as measured by atomic force microscopy. Scanning electron microscopy revealed different surface topographies between manufacturers, varying from typical machined grooves to structural defects like pores and pits. Overnight biofilms were grown on micro-implant surfaces by immersion in pooled human whole saliva. Biofilms on micro-implants treated with chlorhexidine and fluoride mouthrinses contained comparable numbers of viable organisms, but significantly less than did untreated micro-implants. Comparison of different implant systems using multiple linear regression analysis indicated that biofilm formation was governed by roughness of the implant surface and the prevalence of carbon- and oxygen-rich components.

Argon↗

Influence of day and night wear on surface properties of silicone hydrogel contact lenses and bacterial adhesion.

PURPOSE: The aim of this study was to determine the effect of continuous wear on physicochemical surface properties of silicone hydrogel (S-H) lenses and their susceptibility to bacterial adhesion. METHODS: In this study, volunteers wore 2 pairs of either "lotrafilcon A" or "balafilcon A" S-H contact lenses. The first pair was worn continuously for a week and the second pair for 4 weeks. One lens of each pair was used for surface characterization and the other one for bacterial adhesion experiments. Lens surfaces were characterized by examination of their wettability, roughness, elemental composition, and proteins attached to their surfaces. Adhesion of Staphylococcus aureus 835 and Pseudomonas aeruginosa #3 to a lens was studied using a parallel plate flow chamber. RESULTS: Before use, the lotrafilcon A lens was rougher than the balafilcon A lens and had a lower water contact angle and a higher affinity for S. aureus 835. After wear, both lens types had similar water contact angles, whereas the differences in elemental surface composition decreased as well. S. aureus 835 adhered in higher numbers to worn balafilcon A lenses, whereas the opposite was seen for P. aeruginosa #3. The initial deposition rates of both bacterial strains to lotrafilcon A lenses decreased by wearing and were found to correlate significant (P < 0.001) with the surface roughness of worn lenses. CONCLUSIONS: In this study, the differences in surface properties between 2 types of S-H lenses were found to change after 1 week of continuous wear. Generally, bacteria adhered in lower numbers and less tenaciously to worn lenses, except S. aureus 835, adhering in higher numbers to worn balafilcon A lenses.

Bacterial Adhesion↗

Role of lactobacillus cell surface hydrophobicity as probed by AFM in adhesion to surfaces at low and high ionic strength.

The S-layer present at the outermost cell surface of some lactobacillus species is known to convey hydrophobicity to the lactobacillus cell surface. Yet, it is commonly found that adhesion of lactobacilli to solid substrata does not proceed according to expectations based on cell surface hydrophobicity. In this paper, the role of cell surface hydrophobicity of two lactobacillus strains with and without a surface layer protein (SLP) layer has been investigated with regard to their adhesion to hydrophobically or hydrophilically functionalized glass surfaces under well-defined flow conditions and in low and high ionic strength suspensions. Similarly, the interaction of the lactobacilli with similarly functionalized atomic force microscope (AFM) tips was measured. In a low ionic strength suspension, both lactobacillus strains show higher initial deposition rates to hydrophobic glass than to hydrophilic glass, whereas in a high ionic strength suspension no clear influence of cell surface hydrophobicity on adhesion is observed. Independent of ionic strength, however, AFM detects stronger interaction forces when both bacteria and tip are hydrophobic or hydrophilic than when bacteria and tip have opposite hydrophobicities. This suggest that the interaction develops in a different way when a bacterium is forced into contact with the tip surface, like in AFM, as compared with contacts developing between a cell surface and a macroscopic substratum under flow. In addition, the distance dependence of the total Gibbs energy of interaction could only be qualitatively correlated with bacterial deposition and desorption in the parallel plate flow chamber.

Animals↗

Stability and effectiveness against bacterial adhesion of poly(ethylene oxide) coatings in biological fluids.

Poly(ethylene oxide) (PEO) coatings have been shown to reduce the adhesion of different microbial strains and species and thus are promising as coatings to prevent biomaterial-centered infection of medical implants. Clinically, however, PEO coatings are not yet applied, as little is known about their stability and effectiveness in biological fluids. In this study, PEO coatings coupled to a glass substratum through silyl ether bonds were exposed for different time intervals to saliva, urine, or phosphate-buffered saline (PBS) as a reference at 37 degrees C. After exposure, the effectiveness of the coatings against bacterial adhesion was assessed in a parallel plate flow chamber. The coatings appeared effective against Staphylococcus epidermidis adhesion for 24, 48, and 0.5 h in PBS, urine, and saliva, respectively. Using XPS and contact-angle measurements, the variations in effectiveness could be attributed to conditioning film formation. The overall short stability results from hydrolysis of the coupling of the PEO chains to the substratum.

Bacterial Adhesion↗

Atomic force microscopy study on specificity and non-specificity of interaction forces between Enterococcus faecalis cells with and without aggregation substance.

Enterococcus faecalis is one of the leading causes of hospital-acquired infections, and indwelling medical devices are especially prone to infection. E. faecalis expressing aggregation substance (Agg) adheres to biomaterial surfaces by means of positive cooperativity, i.e. the ability of one adhering organism to stimulate adhesion of other organisms in its immediate vicinity. In this study, atomic force microscopy (AFM) was used to measure the specificity and non-specificity of interaction forces between E. faecalis cells with and without Agg. Bacteria were attached to a substratum surface and a tip-less cantilever. Two E. faecalis strains expressing different forms of Agg showed nearly twofold higher interaction forces between bacterial cells than a strain lacking Agg [adhesive force (F(adh)), -1.3 nN]. The strong interaction forces between the strains with Agg were reduced after adsorption of antibodies against Agg from -2.6 and -2.3 nN to -1.2 and -1.3 nN, respectively. This suggests that the non-specific interaction force between the enterococci amounts to approximately 1.2 nN, while the specific force component is only twofold stronger. Comparison of the results of the AFM interaction forces with the positive cooperativity after adhesion to a biomaterial in a parallel-plate flow chamber showed that in the absence of strong interaction forces between the cells, positive cooperativity was also absent. In conclusion, this is believed to be the first time that the influence of specific antibodies on interaction forces between E. faecalis cells has been demonstrated by AFM, thereby experimentally distinguishing between specific and non-specific force components.

Adhesins, Bacterial↗

Atomic force microscopic corroboration of bond aging for adhesion of Streptococcus thermophilus to solid substrata.

Initial bacterial adhesion is considered to be reversible, but over time the adhesive bond between a bacterium and a substratum surface may strengthen, turning the process into an irreversible state. Microbial desorption has been studied in situ in controlled flow devices as a function of the organisms resident time on the surface (J. Colloid Interface Sci. 164 (1994) 355). It appeared that desorption of Streptococcus thermophilus decreased strongly within approximately 50 s after initial adhesion due to bond aging. In this paper, bond aging between the S. thermophilus cell surface and the silicon nitride tip of an AFM (atomic force microscope) is corroborated microscopically and related to the macroscopic, residence time-dependent desorption of the organism under flow. AFM indicated bond strengthening between the tip and the cell surface within 100 s of contact, which is on the same order of magnitude as bond aging inferred from residence time-dependent desorption. Comparison of the interaction energies derived from AFM and macroscopic desorption indicate that bond strengthening arises as a result of multiple attachments of extracellular polymeric substances to a substratum surface.

Bacterial Adhesion↗

Relations between macroscopic and microscopic adhesion of Streptococcus mitis strains to surfaces.

Application of physico-chemical models to describe bacterial adhesion to surfaces has hitherto only been partly successful due to the structural and chemical heterogeneities of bacterial surfaces, which remain largely unaccounted for in macroscopic physico-chemical characterizations of the cell surfaces. In this study, the authors attempted to correlate microscopic adhesion of a collection of nine Streptococcus mitis strains to the negatively charged, hydrophilic silicon nitride tip of an atomic force microscope (AFM) with macroscopic adhesion of the strains to a negatively charged, hydrophilic glass in a parallel-plate flow chamber. The repulsive force probed by AFM upon approach of the tip to a bacterial cell surface ranged from 1.7 to 7.7 nN depending on the strain considered and was found to correspond to an activation barrier, governing initial, macroscopic adhesion of the organisms to the glass surface. Moreover, maximum distances at which attractive forces were probed by the AFM upon retraction of the tip (120 to 1186 nm) were related to the area blocked by an adhering bacterium, i.e. the distance kept between adhering bacteria. Bacterial desorption could not be related to adhesive forces as probed by the AFM, possibly due to the distinct nature of the desorption process occurring in the parallel-plate flow chamber and the forced detachment in AFM.

Bacterial Adhesion↗

Multiple linear regression analysis of bacterial deposition to polyurethane coatings after conditioning film formation in the marine environment.

Many studies have shown relationships of substratum hydrophobicity, charge or roughness with bacterial adhesion, although bacterial adhesion is governed by interplay of different physico-chemical properties and multiple regression analysis would be more suitable to reveal mechanisms of bacterial adhesion. The formation of a conditioning film of organic compounds adsorbed from seawater affects the properties of substratum surfaces prior to bacterial adhesion, which is a complicating factor in studying the mechanism of bacterial adhesion. In this paper, the impact of conditioning films adsorbed from natural seawater to four polyurethane coatings with different hydrophobicity, elasticity and roughness was studied for three different marine bacterial strains in a multiple linear regression analysis. The water contact angle on hydrophobic coatings decreased on average by 8 degrees and increased on average by the same amount on hydrophilic coatings. These changes were accompanied by increased concentrations of oxygen and nitrogen on the surface as determined by X-ray photoelectron spectroscopy, indicative of adsorption of proteinaceous material. Furthermore, the mean surface roughness increased on average by 4 nm after conditioning film formation. Multiple linear regression analysis revealed that changes in deposition due to conditioning film formation of Marinobacter hydrocarbonoclasticus, Psychrobacter sp. SW5H and Halomonas pacifica in a stagnation-point flow chamber could be explained in a model comprising hydrophobicity and the prevalence of nitrogen-rich components on the surface for the most hydrophobic strain. For the two more hydrophilic strains, deposition was governed by a combination of surface roughness and hydrophobicity. Elasticity was not a factor in bacterial adhesion to conditioning films.

Bacterial Adhesion↗

Dynamic cell surface hydrophobicity of Lactobacillus strains with and without surface layer proteins.

Variations in surface hydrophobicity of six Lactobacillus strains with and without an S-layer upon changes in ionic strength are derived from contact angle measurements with low- and high-ionic-strength aqueous solutions. Cell surface hydrophobicity changed in response to changes in ionic strength in three out of the six strains, offering these strains a versatile mechanism to adhere to different surfaces. The dynamic behavior of the cell surface hydrophobicity could be confirmed for two selected strains by measuring the interaction force between hydrophobic and hydrophilic tips with use of atomic force microscopy.

Hydrophobic and Hydrophilic Interactions↗

Influence of wear and overwear on surface properties of etafilcon A contact lenses and adhesion of Pseudomonas aeruginosa.

PURPOSE: To determine changes in physicochemical surface properties of contact lenses (CLs) during daily wear and effects of lens wear on adhesion of a Pseudomonas aeruginosa strain from a patient with CL-related keratitis. METHODS: Ten new CL wearers used ionic, etafilcon A lenses with 58% water on both eyes for approximately 10 hours each day during 10 and 50 days. All lenses were treated daily with an appropriate lens care solution. After the CLs were worn for 10 days (first pair of lenses) and 50 days (second pair, representing overwear), hydrophobicity by water contact angles, surface roughness by atomic force microscope, elemental surface composition by x-ray photoelectron spectroscopy (XPS), and adsorbed proteins by SDS-PAGE were determined on one lens. The lens from the contralateral eye was placed in a parallel plate flow chamber for bacterial adhesion after each time interval. RESULTS: Water contact angles on lenses changed from 45 degrees on unused lenses to 61 degrees +/- 25 degrees after 10 days of wear and changed significantly (P < 0.05) to 27 degrees +/- 14 degrees after 50 days of wear. Surface roughness increased significantly (P < 0.05) from 4 +/- 2 nm (unused) to 10 +/- 7 nm after 50 days of wear. These changes were accompanied by adsorption of proteinaceous material, as evidenced by XPS and SDS-PAGE, demonstrating adsorption of lysozyme, tear lipocalin, and a 30-kDa protein. Initial bacterial adhesion to worn CLs was lower than to unworn CLs. Furthermore, detachment of adhering bacteria from worn lenses was easier than from unworn lenses. The changes observed in the physicochemical surface properties of the lenses after the CLs were worn for 50 days were accompanied by reports of discomfort by 6 of the 10 new CL wearers. Multiple regression analysis revealed that the most predictive variables for an effect on initial deposition after 10 days of wear were hydrophobicity, roughness, the presence of nitrogen-rich material, including the presence of a 30-kDa protein, and the presence of oxygen-rich material-that is, the type of oxygen adsorbed (O equal or parallel C or Ocjs0807;C). After 50 days of wear, roughness and the presence of tear lipocalin were most predictive. CONCLUSIONS: This study demonstrates that the physicochemical surface properties changed after wear and overwear, whereas overwear of the lenses decreased initial adhesion of P. aeruginosa #3 under the present experimental conditions.

Adult↗