Pulmonary function following high-dose radiotherapy of non-small-cell lung cancer.

PURPOSE: To study changes of pulmonary function tests (PFTs) after radiotherapy (RT) of non-small-cell lung cancer (NSCLC) in relation to radiation dose, tumor regression, and changes in lung perfusion. METHODS AND MATERIALS: Eighty-two patients with inoperable NSCLC were evaluated with PFTs (forced expiratory volume in 1 s [FEV(1)] and diffusion capacity [T(L,COc)]), a computed tomography (CT) scan of the chest, and a single photon emission CT (SPECT) lung perfusion scan, before and 3-4 months after RT. The reductions of PFTs and tumor volume were calculated. The lung perfusion was measured from pre- and post-RT SPECT scans, and the difference was defined as the measured perfusion reduction (MPR). In addition, the perfusion post-RT was estimated from the dose distribution using a dose-effect relation for regional lung perfusion, and compared with the pre-RT lung perfusion to obtain the predicted perfusion reduction (PPR). The difference between the actually measured and the PPR was defined as reperfusion. The mean lung dose (MLD) was computed and weighted with the pre-RT perfusion, resulting in the mean perfusion-weighted lung dose (MpLD). Changes of PFTs were evaluated in relation to tumor dose, MLD, MpLD, tumor regression, and parameters related to perfusion changes. RESULTS: In a multivariate analysis, the total tumor dose and MLD were not associated with reductions of PFTs. Tumor regression resulted in a significant improvement of FEV(1) (p = 0.02), but was associated with a reduction of T(L,COc) (p = 0.05). The MpLD and the PPR showed a significant (p = 0.01 to 0.04) but low correlation (r = 0.24 to 0.31) with the reduction of both PFTs. The other parameters for perfusion changes, the MPR and reperfusion were not correlated with changes in PFTs. CONCLUSION: The perfusion-related dose variables, the MpLD or the PPR, are the best parameters to estimate PFTs after RT. Tumor regression is associated with an improvement of FEV(1) and a decline of T(L,COc). Reperfusion was not associated with an improvement of global pulmonary function.

Aged↗

Comparing different NTCP models that predict the incidence of radiation pneumonitis. Normal tissue complication probability.

PURPOSE: To compare different normal tissue complication probability (NTCP) models to predict the incidence of radiation pneumonitis on the basis of the dose distribution in the lung. METHODS AND MATERIALS: The data from 382 breast cancer, malignant lymphoma, and inoperable non-small-cell lung cancer patients from two centers were studied. Radiation pneumonitis was scored using the Southwestern Oncology Group criteria. Dose-volume histograms of the lungs were calculated from the dose distributions that were corrected for dose per fraction effects. The dose-volume histogram of each patient was reduced to a single parameter using different local dose-effect relationships. Examples of single parameters were the mean lung dose (MLD) and the volume of lung receiving more than a threshold dose (V(Dth)). The parameters for the different NTCP models were fit to patient data using a maximum likelihood analysis. RESULTS: The best fit resulted in a linear local dose-effect relationship, with the MLD as the resulting single parameter. The relationship between the MLD and NTCP could be described with a median toxic dose (TD(50)) of 30.8 Gy and a steepness parameter m of 0.37. The best fit for the relationship between the V(Dth) and the NTCP was obtained with a D(th) of 13 Gy. The MLD model was found to be significantly better than the V(Dth) model (p <0.03). However, for 85% of the studied patients, the difference in NTCP calculated with both models was <10%, because of the high correlation between the two parameters. For dose distributions outside the range of the studied dose-volume histograms, the difference in NTCP, using the two models could be >35%. For arbitrary dose distributions, an estimate of the uncertainty in the NTCP could be determined using the probability distribution of the parameter values of the Lyman-Kutcher-Burman model. CONCLUSION: The maximum likelihood method revealed that the underlying local dose-effect relation for radiation pneumonitis was linear (the MLD model), rather than a step function (the V(Dth) model). Thus, for the studied patient population, the MLD was the most accurate predictor for the incidence of radiation pneumonitis.

Breast Neoplasms↗

Importance of accurate dose calculations outside segment edges in intensity modulated radiotherapy treatment planning.

BACKGROUND AND PURPOSE: To assess the effect of differences in the calculation of the dose outside segment edges on the overall dose distribution and the optimisation process of intensity modulated radiation therapy (IMRT) treatment plans. PATIENTS AND METHODS: Accuracy of dose calculations of two treatment planning systems (TPS1 and TPS2) was assessed, to ensure that they are both suitable for IMRT treatment planning according to published guidelines. Successively, 10 treatment plans for patients with prostate and head and neck tumours were calculated in both systems. The calculations were compared in selected points as well as in combination with volumetric parameters concerning the planning target volume (PTV) and organs at risk. RESULTS: For both planning systems, the calculations agree within 2.0% or 3 mm with the measurements in the high-dose region for single and multiple segment dose distributions. The accuracy of the dose calculation is within the tolerances proposed by recent recommendations. Below 35% of the prescribed dose, TPS1 overestimates and TPS2 underestimates the measured dose values, TPS2 being closer to the experimental data. The differences between TPS1 and TPS2 in the calculation of the dose outside segments explain the differences (up to 50% of the local value) found in point dose comparisons. For the prostate plans, the discrepancies between the TPS do not translate into differences in PTV coverage, normal tissue complication probability (NTCP) values and results of the plan optimisation process. The dose-volume histograms (DVH) of the rectal wall differ below 60 Gy, thus affecting the plan optimisation if a cost function would operate in this dose region. For the head and neck cases, the two systems give different evaluations of the DVH points for the PTV (up to 22% differences in target coverage) and the parotid mean dose (1.0-3.0 Gy). Also the results of the optimisation are influenced by the choice of the dose calculation algorithm. CONCLUSIONS: In IMRT, the accuracy of the dose calculation outside segment edges is important for the determination of the dose to both organs at risks and target volumes and for a correct outcome of the optimisation process. This aspect should therefore be of major concern in the commissioning of a TPS intended for use in IMRT. Fulfilment of the accuracy criteria valid for conformal radiotherapy is not sufficient. Three-dimensional evaluation of the dose distribution is needed in order to assess the impact of dose calculation accuracy outside the segment edges on the total dose delivered to patients treated with IMRT.

Head and Neck Neoplasms↗

Portal imaging to assess set-up errors, tumor motion and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer.

PURPOSE: To investigate patient set-up, tumor movement and shrinkage during 3D conformal radiotherapy for non-small cell lung cancer. MATERIALS AND METHODS: In 97 patients, electronic portal images (EPIs) were acquired and corrected for set-up using an off-line correction protocol based on a shrinking action level. For 25 selected patients, the orthogonal EPIs (taken at random points in the breathing cycle) throughout the 6-7 week course of treatment were assessed to establish the tumor position in each image using both an overlay and a delineation technique. The range of movement in each direction was calculated. The position of the tumor in the digitally reconstructed radiograph (DRR) was compared to the average position of the lesion in the EPIs. In addition, tumor shrinkage was assessed. RESULTS: The mean overall set-up errors after correction were 0, 0.6 and 0.2 mm in the x (left-right), y (cranial-caudal) and z (anterior-posterior) directions, respectively. After correction, the standard deviations (SDs) of systematic errors were 1.4, 1.5 and 1.3 mm and the SDs of random errors were 2.9, 3.1 and 2.0 mm in the x-, y- and z-directions, respectively. Without correction, 41% of patients had a set-up error of more than 5 mm vector length, but with the set-up correction protocol this percentage was reduced to 1%. The mean amplitude of tumor motion was 7.3 (SD 2.7), 12.5 (SD 7.3) and 9.4 mm (SD 5.2) in the x-, y- and z-directions, respectively. Tumor motion was greatest in the y-direction and in particular for lower lobe tumors. In 40% of the patients, the projected area of the tumor regressed by more than 20% during treatment in at least one projection. In 16 patients it was possible to define the position of the center of the tumor in the DRR. There was a mean difference of 6 mm vector length between the tumor position in the DRR and the average position in the portal images. CONCLUSIONS: The application of the correction protocol resulted in a significant improvement in the set-up accuracy. There was wide variation in the observed tumor motion with more movement of lower lobe lesions. Tumor shrinkage was observed. The position of the tumor on the planning CT scan did not always coincide with the average position as measured during treatment.

Adult↗

First results of a phase I/II dose escalation trial in non-small cell lung cancer using three-dimensional conformal radiotherapy.

PURPOSE: To evaluate the feasibility of dose escalation in non-small cell lung cancer (NSCLC) using three-dimensional conformal radiation therapy. PATIENTS AND METHODS: The main eligibility criteria of the trial were: pathologically proven inoperable NSCLC, ECOG performance status or=grade 3 (SWOG), grade 3 early and grade 2 late esophageal toxicity or any other (RTOG) grade 3 or 4 complications). RESULTS: Fifty-five patients were included. Tumor stage was I/II in 47%, IIIA in 33% and IIIB in 20%. The majority of the patients received a dose of 74.3 Gy (n=17) or 81.0 Gy (n=23). Radiation pneumonitis occurred in seven patients: four patients developed a grade 2, two patients grade 3 and one patient a grade 4. Esophageal toxicity was mild. In 50 patients tumor response at 3 months follow-up was evaluable. In six patients a complete response was recorded, in 38 a partial response, five patients had stable disease and one patient experienced progressive disease. Only one patient developed an isolated failure in an uninvolved nodal area. So far the radiation dose was safely escalated to 87.8 Gy in group 1 (lowest rMLD), 81.0 Gy in groups 2 and 3 and 74.3 Gy in group 4. CONCLUSION: Three-dimensional conformal radiotherapy enables significant dose escalation in NSCLC. The maximum tolerable dose has not yet been reached in any risk group.

Adult↗

Incorporating an improved dose-calculation algorithm in conformal radiotherapy of lung cancer: re-evaluation of dose in normal lung tissue.

BACKGROUND AND PURPOSE: The low density of lung tissue causes a reduced attenuation of photons and an increased range of secondary electrons, which is inaccurately predicted by the algorithms incorporated in some commonly available treatment planning systems (TPSs). This study evaluates the differences in dose in normal lung tissue computed using a simple and a more correct algorithm. We also studied the consequences of these differences on the dose-effect relations for radiation-induced lung injury. MATERIALS AND METHODS: The treatment plans of 68 lung cancer patients initially produced in a TPS using a calculation model that incorporates the equivalent-path length (EPL) inhomogeneity-correction algorithm, were recalculated in a TPS with the convolution-superposition (CS) algorithm. The higher accuracy of the CS algorithm is well-established. Dose distributions in lung were compared using isodoses, dose-volume histograms (DVHs), the mean lung dose (MLD) and the percentage of lung receiving >20 Gy (V20). Published dose-effect relations for local perfusion changes and radiation pneumonitis were re-evaluated. RESULTS: Evaluation of isodoses showed a consistent overestimation of the dose at the lung/tumor boundary by the EPL algorithm of about 10%. This overprediction of dose was also reflected in a consistent shift of the EPL DVHs for the lungs towards higher doses. The MLD, as determined by the EPL and CS algorithm, differed on average by 17+/-4.5% (+/-1SD). For V20, the average difference was 12+/-5.7% (+/-1SD). For both parameters, a strong correlation was found between the EPL and CS algorithms yielding a straightforward conversion procedure. Re-evaluation of the dose-effect relations showed that lung complications occur at a 12-14% lower dose. The values of the TD(50) parameter for local perfusion reduction and radiation pneumonitis changed from 60.5 and 34.1 Gy to 51.1 and 29.2 Gy, respectively. CONCLUSIONS: A simple tissue inhomogeneity-correction algorithm like the EPL overestimates the dose to normal lung tissue. Dosimetric parameters for lung injury (e.g. MLD, V20) computed using both algorithms are strongly correlated making an easy conversion feasible. Dose-effect relations should be refitted when more accurate dose data is available.

Algorithms↗

A model to simulate day-to-day variations in rectum shape.

PURPOSE: To develop a model that predicts possible rectum configurations that can occur during radiotherapy of prostate cancer on the basis of a planning CT scan and patient group data. MATERIALS AND METHODS: We used a stochastic shape description model with a limited number of parameters (area, area difference, and curvature) on a slice-by-slice basis to simulate rectum motion. The probability distributions of the chosen parameters were obtained from a group of 9 reference patients, who each received 15-17 repeat CT scans. We used a Monte Carlo technique to generate different rectum configurations from the probability distributions. We verified the model by comparing dose-wall histograms (DWHs) of the originally delineated rectal contours and simulated rectums for a three-field treatment technique with a prescription dose of 78 Gy. The 15-17 sets of rectal contours of each patient are regarded as the golden standard and provide a good estimate of the actual dose received during the treatment. We determined the equivalent uniform dose (EUD) for a quantitative comparison between the actual dose, the dose predicted on the basis of the simulations, and the dose predicted on the basis of a single planning CT scan. RESULTS: The simulated rectum configurations yield a better estimate of the actual dose in the rectal wall than the rectum in the planning CT scan alone. The differences between the EUD based on the planning CT scan and the actual EUD ranged between -1.1 Gy and 2.1 Gy, with respect to a mean actual EUD of 69.8 Gy. This range is smaller for the EUD based on the simulated rectums, namely -0.4 Gy to 0.6 Gy. Furthermore, the simulation generates a set of rectum configurations that provides an estimate of the variation in DWHs during the course of the treatment. This estimate can be used in addition to the DWH of the planning CT scan in the analysis of gastrointestinal toxicity. CONCLUSIONS: To simulate rectum shapes, we have developed a model that can be used in addition to the information available in the planning CT scan in the analysis of the received dose to the rectal wall during radiotherapy of prostate cancer.

Algorithms↗

Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy.

PURPOSE: In this work, three-dimensional (3D) motion of lung tumors during radiotherapy in real time was investigated. Understanding the behavior of tumor motion in lung tissue to model tumor movement is necessary for accurate (gated or breath-hold) radiotherapy or CT scanning. METHODS: Twenty patients were included in this study. Before treatment, a 2-mm gold marker was implanted in or near the tumor. A real-time tumor tracking system using two fluoroscopy image processor units was installed in the treatment room. The 3D position of the implanted gold marker was determined by using real-time pattern recognition and a calibrated projection geometry. The linear accelerator was triggered to irradiate the tumor only when the gold marker was located within a certain volume. The system provided the coordinates of the gold marker during beam-on and beam-off time in all directions simultaneously, at a sample rate of 30 images per second. The recorded tumor motion was analyzed in terms of the amplitude and curvature of the tumor motion in three directions, the differences in breathing level during treatment, hysteresis (the difference between the inhalation and exhalation trajectory of the tumor), and the amplitude of tumor motion induced by cardiac motion. RESULTS: The average amplitude of the tumor motion was greatest (12 +/- 2 mm [SD]) in the cranial-caudal direction for tumors situated in the lower lobes and not attached to rigid structures such as the chest wall or vertebrae. For the lateral and anterior-posterior directions, tumor motion was small both for upper- and lower-lobe tumors (2 +/- 1 mm). The time-averaged tumor position was closer to the exhale position, because the tumor spent more time in the exhalation than in the inhalation phase. The tumor motion was modeled as a sinusoidal movement with varying asymmetry. The tumor position in the exhale phase was more stable than the tumor position in the inhale phase during individual treatment fields. However, in many patients, shifts in the exhale tumor position were observed intra- and interfractionally. These shifts are the result of patient relaxation, gravity (posterior direction), setup errors, and/or patient movement.The 3D trajectory of the tumor showed hysteresis for 10 of the 21 tumors, which ranged from 1 to 5 mm. The extent of hysteresis and the amplitude of the tumor motion remained fairly constant during the entire treatment. Changes in shape of the trajectory of the tumor were observed between subsequent treatment days for only one patient. Fourier analysis revealed that for 7 of the 21 tumors, a measurable motion in the range 1-4 mm was caused by the cardiac beat. These tumors were located near the heart or attached to the aortic arch. The motion due to the heartbeat was greatest in the lateral direction. Tumor motion due to hysteresis and heartbeat can lower treatment efficiency in real-time tumor tracking-gated treatments or lead to a geographic miss in conventional or active breathing controlled treatments. CONCLUSION: The real-time tumor tracking system measured the tumor position in all three directions simultaneously, at a sampling rate that enabled detection of tumor motion due to heartbeat as well as hysteresis. Tumor motion and hysteresis could be modeled with an asymmetric function with varying asymmetry. Tumor motion due to breathing was greatest in the cranial-caudal direction for lower-lobe unfixed tumors.

Adenocarcinoma↗

Margins for translational and rotational uncertainties: a probability-based approach.

PURPOSE: To define margins for systematic rotations and translations, based on known statistical distributions of these deviations. METHODS AND MATERIALS: The confidence interval-based expansion method for translations, known as the "rolling ball algorithm," was extended to include rotations. This new method, which we call the Rotational and Translational Confidence Limit (RTCL) method, is exact for a point with arbitrary rotations and translations or for a finite shape with rotations only. The method was compared with two existing expansion methods: a rolling ball algorithm without rotations, and a convolution (blurring) method which included rotations. On the basis of these methods, planning target volumes (PTVs, expanded clinical target volumes [CTVs]) were constructed for a number of shapes (a sphere, a sphere with an extension, and three prostate cases), and evaluated in several ways by means of a Monte Carlo method. The accuracy of each method was measured by determining the probability of finding the CTV completely inside the PTV (P(CTVinPTV)), using parameters that yield a 90% probability for a sphere-shaped CTV without rotations. Furthermore, with the expansion parameters adjusted to give an equal P(CTVinPTV) for all methods, PTV volumes were compared. RESULTS: With the expansion algorithm parameters chosen to yield P(CTVinPTV) = 90% for a sphere, an average P(CTVinPTV) of 84%, 57%, and 46% was obtained for the other shapes, using the RTCL method, coverage probability, and rolling ball, respectively. With the parameters adjusted to yield an equal P(CTVinPTV) for all methods, the PTV volume was on average 8% larger for the coverage probability method and 15% larger for the rolling ball algorithm compared to the RTCL method. CONCLUSION: The RTCL method provides an accurate way to include the effects of systematic rotations in the margin. Compared to other algorithms, the method is less sensitive to the shape of the CTV, and, given a fixed probability of finding the CTV inside the PTV, a smaller PTV volume can be obtained.

Algorithms↗

Inclusion of geometric uncertainties in treatment plan evaluation.

PURPOSE: To correctly evaluate realistic treatment plans in terms of absorbed dose to the clinical target volume (CTV), equivalent uniform dose (EUD), and tumor control probability (TCP) in the presence of execution (random) and preparation (systematic) geometric errors. MATERIALS AND METHODS: The dose matrix is blurred with all execution errors to estimate the total dose distribution of all fractions. To include preparation errors, the CTV is randomly displaced (and optionally rotated) many times with respect to its planned position while computing the dose, EUD, and TCP for the CTV using the blurred dose matrix. Probability distributions of these parameters are computed by combining the results with the probability of each particular preparation error. We verified the method by comparing it with an analytic solution. Next, idealized and realistic prostate plans were tested with varying margins and varying execution and preparation error levels. RESULTS: Probability levels for the minimum dose, computed with the new method, are within 1% of the analytic solution. The impact of rotations depends strongly on the CTV shape. A margin of 10 mm between the CTV and planning target volume is adequate for three-field prostate treatments given the accuracy level in our department; i.e., the TCP in a population of patients, TCP(pop), is reduced by less than 1% due to geometric errors. When reducing the margin to 6 mm, the dose must be increased from 80 to 87 Gy to maintain the same TCP(pop). Only in regions with a high-dose gradient does such a margin reduction lead to a decrease in normal tissue dose for the same TCP(pop). Based on a rough correspondence of 84% minimum dose with 98% EUD, a margin recipe was defined. To give 90% of patients at least 98% EUD, the planning target volume margin must be approximately 2.5 Sigma + 0.7 sigma - 3 mm, where Sigma and sigma are the combined standard deviations of the preparation and execution errors. This recipe corresponds accurately with 1% TCP(pop) loss for prostate plans with clinically reasonable values of Sigma and sigma. CONCLUSION: The new method computes in a few minutes the influence of geometric errors on the statistics of target dose and TCP(pop) in clinical treatment plans. Too small margins lead to a significant loss of TCP(pop) that is difficult to compensate for by dose escalation.

Algorithms↗

Irradiation of paranasal sinus tumors, a delineation and dose comparison study.

PURPOSE: To determine the influence of observer variation and treatment planner variation on the dose delivered to the target and normal structures when irradiating paranasal sinus carcinomas. PATIENTS AND METHODS: Nine patients with paranasal sinus tumors underwent debulking surgery and subsequent radiation therapy. Two observers from two different institutions delineated the clinical target volumes (CTVs) for the elective and the boost volumes. These volumes were expanded in three dimensions with a 5-mm margin. At both institutions, a three-dimensional conformal treatment plan of 46 Gy to the elective volumes, plus 20 Gy to the boost target volumes, was designed. The delineated volumes and treatment plans were compared. RESULTS: The mean volume ratio between institutions of the elective CTVs was 0.9 (standard error = 0.05). The differences were located mainly at the bottom of the nasal cavity and at the frontal border of the target areas. The differences in boost CTVs were large; the mean volume ratio was 2.6 (standard error = 0.58). After expansion of the CTV, the mean distance between the planning target volume (PTV) and the chiasm differed by 0.5 cm between the two institutions. Cases with smaller distances between the PTV and the chiasm had more underdosage to the PTV. This effect was less pronounced for institution A (1 vol.%/cm) than for institution B (10 vol.%/cm) treatment plans, which were less conformal. When the treatment plan was designed for the PTV of institution B, 23 volume % of the PTV of institution A received <95% of the prescribed dose. If the treatment plan was designed for the (on average larger) PTV of institution A, the underdosed volume of PTV at institution B was 17%. The relative underdosage to the "other" PTV was larger when the original treatment plan was more conformal. CONCLUSION: In the irradiation of paranasal sinus cancer, both the treatment planner and the observer have a significant influence on the dose to the target and organs at risk. Both effects are similar in magnitude. The observer effect increases with more conformal treatment plans. Minimizing the observer variation is important for adequate irradiation of paranasal sinus cancer.

Carcinoma, Adenoid Cystic↗

Reduction of rectal dose by integration of the boost in the large-field treatment plan for prostate irradiation.

PURPOSE: To reduce the dose in the rectal wall from prostate irradiation at high dose levels. METHODS AND MATERIALS: Treatment plans in which the boost fields were integrated into the large fields (simultaneous integrated boost [SIB]) were compared with plans in which the large fields and boost fields were planned individually and applied in a sequential manner (sequential boost). Two target volumes were delineated: PTV1, the target volume of the large fields that is irradiated to 68 Gy, and PTV2, the target volume of the boost fields that is irradiated to 10 Gy. The sequential boost and the SIB were normalized to the mean dose in PTV2, being 78 Gy. We used a five-field intensity-modulated radiotherapy (IMRT) technique, applied in a step and shoot mode, and included beam weight optimization. A set of 5 patients with varying degree of overlap between PTV1 and the rectal wall was used for analysis. RESULTS: The SIB resulted in a reduction of the dose in the rectal wall. Rectal normal tissue complication probability (NTCP) decreased for the SIB, on average, by a factor of almost 2, compared with the sequential boost. CONCLUSION: The SIB reduced the dose in the rectal wall, compared with the sequential boost technique.

Adenocarcinoma↗

Optimizing radiation treatment plans for lung cancer using lung perfusion information.

PURPOSE: To study the impact of incorporation of lung perfusion information in the optimization of radical radiotherapy (RT) treatment plans for patients with medically inoperable non-small cell lung cancer (NSCLC). MATERIALS AND METHODS: The treatment plans for a virtual phantom and for five NSCLC patients with typical defects of pre-RT lung perfusion were optimized to minimize geometrically determined parameters as the mean lung dose (MLD), the lung volume receiving more than 20 Gy (V20), and the functional equivalent of the MLD, using perfusion-weighted dose-volume histograms. For the patients the (perfusion-weighted) optimized plans were compared to the clinically applied treatment plans. RESULTS: The feasibility of perfusion-weighted optimization was demonstrated in the phantom. Using perfusion information resulted in an increase of the weights of those beams that were directed through the hypo-perfused lung regions both for the phantom and for the studied patients. The automatically optimized dose distributions were improved with respect to lung toxicity compared with the clinical treatment plans. For patients with one hypo-perfused hemi-thorax, the estimated gain in post-RT lung perfusion was 6% of the prescribed dose compared to the geometrically optimized plan. For patients with smaller perfusion defects, perfusion-weighted optimization resulted in the same plan as the geometrically optimized plan. CONCLUSION: Perfusion-weighted optimization resulted in clinically well applicable treatment plans, which cause less radiation damage to functioning lung for patients with large perfusion defects.

Carcinoma, Non-Small-Cell Lung↗