Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Acute Disease↗

Early detection of left ventricular diastolic dysfunction in Chagas' disease.

BACKGROUND: Chagas' disease may cause left ventricular diastolic dysfunction and its early detection in asymptomatic patients would allow to stratify the risk and to optimize medical treatment. The aim of this study is to investigate if transmitral Doppler flow can detect early abnormalities of the diastolic left ventricular function in patients during the indeterminate phase of Chagas' disease, in which the electrocardiogram (ECG), chest x-ray and 2-D echocardiogram (2D-echo) are normal. METHODS: a group of 54 patients with Chagas' disease was studied and compared to a control group of 27 subjects of similar age. All were assessed with an ECG, chest X-ray, 2-D echo, and transmitral Doppler flow. RESULTS: both groups had similar values in the 2D-echo. In patients with Chagas' disease, the transmitral Doppler showed a higher peak A velocity (control group: 0.44 m/sec, Chagas group: 0.55 m/sec, p = 0.001), a lower E/A ratio (control group: 1.45, Chagas group: 1.22, p < 0.05), and a lengthening of the deceleration time of early diastolic filling (control: 138.7 +/- 26.8 msec, Chagas group: 167.9 +/- 34.6 msec, p = 001), thus revealing an early disorder of the diastolic left ventricular function in patients with Chagas' disease. CONCLUSION: in patients with Chagas' disease who are in the indeterminate phase, transmitral Doppler flow allowed to identify early abnormalities of the left ventricular diastolic function, which provide useful clinical information for prognostic stratification and treatment.

Adult↗

Usefulness of myocardial contrast echocardiography early after acute myocardial infarction.

OBJECTIVES: (1) Evaluate wall motion and perfusion abnormalities after reperfusion therapy of the culprit lesion, (2) delineate the ability of myocardial contrast echocardiography (MCE) to evaluate the microvasculature after reperfusion, in order to distinguish between stunning and necrosis in the risk area. METHODS: We analyzed 446 segments from 28 patients, 10 normal controls (160 segments), and 18 with a first AMI (286 segments). MCE was obtained with Optison and a two-dimensional echocardiography was performed at 3 months post acute myocardial infarction (AMI). RESULTS: In the group with AMI, we analyzed 286 segments, of which 107 had wall motion abnormalities (WMA) related to the culprit artery. Two subgroups were identified: Group I with WMA and normal perfusion (50 segments, 47%) and Group II with WMA and perfusion defects (57 segments, 53%). According to the 2D echocardiogram at 3 months, they were further subdivided into: Group IA: with wall motion improvement (stunning): 18 segments, 36%, Group IB: without wall motion improvement: 32 segments, 64%, Group IIA: with wall motion improvement: 12 segments, 21%, Group IIB: without wall motion improvement (necrosis): 45 segments, 79%. CONCLUSIONS: (1) The presence of myocardial perfusion in segments with WMA immediately after AMI reperfusion therapy predicts viability in most patients. Conversely, the lack of perfusion is not an absolute indicator of the presence of necrosis. (2) Perfusion defects allow to detect patients with thrombolysis in myocardial infarction (TIMI) 3 flow and "no-reflow" phenomenon who will not show improved wall motion in the 2D echocardiogram. However, some patients with initial no-reflow could have microvascular stunning and their regional contractile function will normalize after a recovery period.

Adult↗

[Usefulness of pulsed Doppler tissue imaging in the early detection of diastolic myocardial abnormalities in first-degree relatives of patients with familial hypertrophic cardiomyopathy].

INTRODUCTION AND OBJECTIVES: Doppler tissue imaging (DTI) enables regional myocardial function to be assessed irrespective of preload. Our aim was to determine the usefulness of DTI in healthy relatives of patients with familial hypertrophic cardiomyopathy. PATIENTS AND METHOD: We studied 47 first-degree relatives of patients with familial hypertrophic cardiomyopathy (group GI) and 47 normal subjects (group GII). Echocardiographic studies, including DTI, were performed in both groups. DTI was used to measure myocardial velocities during systole (S'), early diastole (E') and atrial contraction (A') at the mitral annulus, septum, and tricuspid annulus. Isovolumic relaxation and contraction times were corrected for heart rate. With DTI assessment of regional diastolic myocardial function and use of the E'/A' ratio, normal (i.e., E'/A'>1) and abnormal (i.e., E'/A'<1) diastolic function could be distinguished. RESULTS: There were no abnormalities in regional diastolic function in group GII (right E'/A' 1.78 (0.58), septum E'/A' 2.03 (0.53), and left E'/A' 2.55 (0.80). However, in group GI, two subgroup could be distinguished using E'/A' ratio values: group GIa comprised 37 first-degree relatives with normal diastolic function (right E'/A' 1.8 (0.44), septum E'/A' 2.07 (0.41), and left E/A 2.35 (0.6) who did not differ significantly from control subjects, and group GIb comprised 10 first-degree relatives with abnormal right diastolic function (right E'/A' 0.70 (0.28), P<.001) but with less significant differences at the septum (1.57 (0.49), P<.01) and mitral annulus (1.85 (0.53), P<.01). CONCLUSIONS: In 10 of 47 (21.3%) first-degree relatives of patients with familial hypertrophic cardiomyopathy, DTI enabled the detection of ventricular diastolic abnormalities, which were more evident in the right ventricle. They could be a preclinical manifestation of disease.

Adolescent↗

Cinefluoroscopic assessment of mechanical disc prostheses: its value as a complementary method to echocardiography.

BACKGROUND AND AIM OF THE STUDY: Many types of mechanical prostheses are used for heart valve replacement, but it is difficult to distinguish between them using transthoracic echocardiography. Hence, cinefluoroscopy complements the echocardiographic evaluation of cardiac prostheses. The aims of the present study were to: (i) describe the contribution of cinefluoroscopy in identifying different prostheses; (ii) compare gradients obtained by Doppler echocardiography with the opening angle of the discs assessed by cinefluoroscopy; and (iii) assess the ability of cinefluoroscopy to distinguish normal from dysfunctional prostheses. METHODS: A total of 229 mechanical disc prostheses was prospectively evaluated with cinefluoroscopy. Eight prosthetic valves (six aortic, two mitral) were excluded due to the coexistence of severe left ventricular dysfunction. Thus, the final analysis comprised 221 prosthetic valves (146 aortic, 75 mitral). RESULTS: Based on the characteristics of the ring and the discs, cinefluoroscopy identified 87 single-leaflet and 134 bileaflet prostheses. Disc motion allowed distinction to be made between normal and dysfunctional prostheses (opening angle: 74 +/- 13 degrees versus 49 +/- 18 degrees). Fluoroscopy could not define disc profile or the ring in 6% of aortic valves and in 26% of mitral prostheses. The technique could be used to identify the TriTechnologies and HP-Biplus valves, but could not provide data on prosthetic function due to radiolucency of the discs. Among the 146 aortic prostheses, Doppler echocardiography helped to identify 109 normal valves and 37 dysfunctional valves. Among 75 mitral prostheses, 54 normal and 21 dysfunctional prosthetic valves were identified. When both methods were correlated, the sensitivity, specificity and positive and negative predictive values of fluoroscopy to distinguish normal from malfunctioning prostheses were 83%, 80%, 89%, and 71%, respectively. CONCLUSION: Each prosthesis type has radioscopic characteristics that allow its identification. Fluoroscopy permitted rapid and easy evaluation of mechanical prosthetic valve function, and in most cases allowed a distinction to be made between normal and dysfunctional prostheses. The presence of high gradients by Doppler echocardiography, with normal opening angles by fluoroscopy, and without pannus on transesophageal echocardiography, is indicative of patient-prosthesis mismatch. Fluoroscopy was superior to echocardiography in identifying disc motion, whilst Doppler study allowed the measurement of gradients and areas, and semiquantification of regurgitation. Thus, cinefluooscopy rapidly provides valuable information which is complementary to that obtained by echocardiography.

Aged↗

Left cavities spontaneous contrast opacification.

We report a transesophageal echocardiography study of a patient in a critical care unit under mechanical respiratory assistance in whom left cavities spontaneous contrast opacification was seen, suggesting systemic gas embolism as the probable mechanism.

Contrast Media↗