PubMed Health⌕ Search

Biomedical subjects

Jorge López Ayerbe

Publications and source records attributed to Jorge López Ayerbe.

3 recordsLinked to original sources

[Temporary pacemakers: current use and complications].

INTRODUCTION AND OBJECTIVE: Temporary pacemakers (TP) are used in the emergency treatment of patients with severe bradyarrhythmia. They are often used in emergency situations and for older patients in poor general condition who are hemodynamically unstable and uncooperative. The aim of this study was to review and analyze the indications, incidence and type of complications associated with TP implanted in our center during a 6-year period. PATIENTS AND METHOD: We analyzed significant clinical variables, indication, route of insertion, follow-up, complications, and duration of temporary pacing. RESULTS: A total of 568 TP were implanted, and 530 cases were available for review (mean age 74.8 [11] years). The main indications were symptomatic complete AV block (51%), prophylaxis for replacement with a definitive pacemaker (14.7%), blockage in the acute phase of myocardial infarction (12.6%), bradyarrhythmia due to drug intoxication (12.2%), symptomatic sick sinus syndrome (7.5%) and long QT interval or ventricular tachycardia (2.5%). The route of insertion was via the femoral vein in 99% of the cases. The duration of TP use was 4.2 days (range 1 to 31 days). A total of 369 patients (69.6%) required a permanent pacemaker. COMPLICATIONS: 34 patients died (6.4%), but only 3 deaths were attributable to TP implantation. Other severe complications were seen in 98 patients (18.5%). Malfunction of the TP occurred in 48 patients (9%) because of electrode displacement. CONCLUSIONS: Temporary pacemakers are used in older patients with extreme bradyarrhythmia and occasionally with acute myocardial infarction. Serious complications are not uncommon (22% of all patients), and can range from femoral hematoma to cardiac tamponade and even death (6%). In 9% of the patients the electrode needed to be repositioned because of failure of sensing or loss of ventricular capture.

Adolescent↗

Necrotizing vasculitis: a cause of aortic insufficiency and conduction system disturbance.

Cardiac involvement in vasculitis syndromes is uncommon. We describe a 50-year-old male who presented with progressive dyspnea and myalgies. Echocardiogram revealed significant thickening of aortic root, aortic cusps, and anterior mitral valve leaflet, with severe aortic regurgitation that required aortic valve replacement. Furthermore, this patient suffered progressive atrioventricular block that needed implantation of a pacemaker. The study performed disclosed the presence of necrotizing vasculitis positive for perinuclear antineutrophil cytoplasmic antibody.

Aortic Valve Insufficiency↗

[Predictive factors of abnormal dynamic intraventricular gradient after valve replacement in severe aortic stenosis].

INTRODUCTION: Dynamic intraventricular gradients (DIG) after valve replacement in severe aortic stenosis have been reported, although the incidence of DIG and clinical signs are still poorly understood.Aim. To evaluate the incidence of DIG)and determine risk factors and associated morbimortality. PATIENTS AND METHOD: One hundred nine consecutive patients with severe aortic valve stenosis undergoing valve replacement were studied prospectively by echocardiography to detect the postoperative appearance of DIG, defined as a maximum flow velocity >/= 2.5 m/s. RESULTS: Sixteen patients (14.9%) developed postoperative DIG. Significant differences between the patients with or without DIG were found for ventricular diameter (left end-diastolic ventricular diameter (LEDVD) 43.2 vs. 47.7 mm, respectively, p < 0.001; left end-systolic ventricular diameter (LESVD) 21 vs. 29 mm, p < 0.001); left ventricular mass index (165 vs. 193 g/m(2), p < 0.05); mean aortic valve gradient (68 vs. 59 mmHg, p < 0.01),; ejection fraction (73 vs. 61%, p < 0.001). No significant differences were found with respect to ventricular wall thicknesses (septal 16.3 vs. 15.7; posterior 14.37 vs. 14.62), the presence of aortic insufficiency, or other postoperative factors (anemia, inotropic agents, etc.). CONCLUSIONS: DIG after aortic valve replacement to treat severe stenosis is not unusual (15%). DIG is usually found at a midventricular location, close to the septum. In patients with postoperative DIG the most common associated factors were small LEDVD, high ejection fractions and ratios of intraventricular septal to posterior wall ratios, high valve gradients and small left ventricular masses. Preoperative echocardiography can identify patients with a higher risk of developing DIG after aortic valve replacement.

Adult↗