PubMed Health⌕ Search

Biomedical subjects

Joris R Delanghe

Publications and source records attributed to Joris R Delanghe.

39 records · Page 3Linked to original sources

Novel haptoglobin insertion/deletion polymorphism is associated with the lipid profile and C-reactive protein (CRP) concentration.

We discovered a hitherto undescribed insertion/deletion (I/D) polymorphism of 7 base pairs in intron 4 of the HP1 allele and intron 4 and 6 of the HP2 allele. Genotyping was performed in 311 Belgian subjects. The association between serum haptoglobin (Hp) and lipid concentrations and the Hp I/D genotypes was investigated. Genotype distribution in 103 Hp 1-1 phenotypes (50.5% DD, 39.8% DI, 9.7% II) and D allele frequency (0.70) were in close agreement with the Hardy-Weinberg equilibrium. No association between Hp concentrations and the Hp I/D genotypes could be found. Apolipoprotein (apo)A2, apoB and cholesterol concentrations were slightly lower in Hp II compared to DI and DD. Low-density lipoprotein (LDL)-cholesterol and ultrasensitive C-reactive protein (CRP) concentrations and the apoA1/apoA2 ratios differed significantly between Hp D/I genotypes. We added a further component to the molecular heterogeneity of Hp by the detection of an I/D polymorphism. Studies on the Hp I/D polymorphism in various populations open perspectives for further investigation of the distribution pattern of the human Hp gene. The association of the Hp I/D polymorphism with various lipid parameters might add a further component to the complex and multifaceted lipid metabolism.

Adult↗

Iron status in black persons is not influenced by haptoglobin polymorphism.

Iron status in man is influenced by environmental and genetic factors. The molecular variation of haptoglobin is one of the genetic factors influencing iron status in Caucasians. Differences in iron metabolism between blacks and whites have been reported. We wanted to investigate the effect of haptoglobin polymorphism on iron status in blacks. We studied 300 African subjects who were apparently healthy with normal erythrocyte sedimentation rate and with no increase in dietary iron because of traditional beer consumption. We determined haptoglobin (Hp) phenotypes using starch gel electrophoresis and measured indirect iron status indices using standard methods. We compared iron status indices according to haptoglobin type. Ninety two individuals (31%) had Hp 1-1, 114 persons (38%) had Hp 2-1, 20 subjects (7%) had Hp 2-1(Modified) and 54 individuals (18%) had Hp 2-2 type. Haptoglobin was not detectable in 19 subjects and Hp 2-1(Johnson) was found in one subject. In both males and females, serum iron concentration, total iron binding capacity, transferrin saturation and ferritin concentration were not different with regard to Hp phenotype. These results suggest that haptoglobin phenotypic variation may not be a factor which influences iron status in black persons.

Adolescent↗

Quantitative evaluation of urinalysis test strips.

BACKGROUND: Urine test strip results are generally reported in categories (i.e., ordinal scaled), but automated strip readers are now available that can report quantitative data. We investigated the possible use of these meters to complement flow cytometry of urine and compared reflectance readings with quantitative determinations of urinary glucose and microalbumin. METHODS: We compared URISYS 2400 (Roche) quantitative reflectance data with data from the UF-100 (Sysmex) and biochemical data for 436 nonpathologic and pathologic urine samples. RESULTS: Reproducibility of the reflectance signal was good for high- and low-concentration urine pools for protein (0.8% and 0.9% and 1.5% and 2.2% within and between runs, respectively), leukocyte esterase (1.1% and 1.0%; 5.1% and 1.2%), hemoglobin (1.7% and 1.1%; 8.9% and 1.1%) and glucose (2.1% and 0.5%; 6.5% and 2.3%). Fair agreement was obtained between UF-100 and test strip reflectance data for erythrocytes and hemoglobin (r = -0.680) and leukocytes and leukocyte esterase (r = -0.688). Higher correlations were observed for biochemical and test strip data comparing protein and albumin (r = -0.825) and glucose data (r = -0.851). The lower limits of detection for erythrocytes and leukocytes were 8 x 10(6)/L and 19 x 10(6)/L, respectively. The protein test (n = 220) detected 86% (95% confidence interval, 78-92%) of samples with <30 mg/L albumin with a specificity of 84% (95% confidence interval, 76-91%). CONCLUSIONS: In urine test strip analysis, quantitative hemoglobin and leukocyte esterase reflectance data are complementary with flow cytometric results and glucose and albumin results.

Albumins↗