PubMed Health⌕ Search

Biomedical subjects

Jos M A van Engelshoven

Publications and source records attributed to Jos M A van Engelshoven.

At least 19 recordsLinked to original sources

Magnetic resonance angiography and neuromonitoring to assess spinal cord blood supply in thoracic and thoracoabdominal aortic aneurysm surgery.

OBJECTIVE: Preoperative knowledge of the blood-supplying trajectory to the spinal cord is of interest, because spinal cord ischemia may occur during thoracic aortic aneurysm (TAA) and thoracoabdominal aortic aneurysm (TAAA) repair and possibly leads to paraplegia. The Adamkiewicz artery (AKA) is considered to be the most important blood supplier of the thoracolumbar spinal cord and has therefore been the focus in preoperative diagnostic imaging. However, in TAA(A) patients, the blood supply to the spinal cord may strongly depend on (intersegmental) collateral circulation, because many segmental arteries are occluded as a result of atherosclerosis. Therefore, the importance of preserving the segmental artery supplying the AKA (SA-AKA) is debated. Here it was investigated whether (1) the AKA and its segmental supplier can be imaged by using magnetic resonance (MR) angiography and (2) aortic cross-clamping of the SA-AKA influences intraoperative spinal cord function, monitored by motor evoked potentials (MEPs). METHODS: Preoperative MR angiography was performed to localize the SA-AKA and the AKA in 60 patients (19 TAA, 7 TAAA I, 18 TAAA II, 9 TAAA III, and 7 TAAA IV). Spinal cord function was monitored during surgery by using MEPs. When MEPs indicated critical ischemia, the SA-AKA was selectively reattached. To test whether aortic cross-clamping of the SA-AKA was associated with MEP decline, the Fisher statistical exactness test was applied. RESULTS: The AKA and SA-AKA could be localized in all 60 (100%) patients between vertebral levels T8 and L2 (72% left sided). In 44 (73%) patients, the SA-AKA was cross-clamped, which led in 32% (14/44) of cases to MEP decline. Reattachment of the preoperatively localized SA-AKA re-established MEPs and, thus, spinal cord function in 12 of 14 cases. When the SA-AKA was outside the area cross-clamped, the MEPs always remained stable. A significant association (P < .01) was found between the location of the SA-AKA relative to the aortic cross-clamps and the MEPs. CONCLUSIONS: The AKA can be localized before surgery in 100% of TAA(A) patients by using MR angiography. Location of the SA-AKA outside the cross-clamped aortic area is attended with stable MEPs. Interestingly, it was found that in most patients in whom the SA-AKA was cross-clamped, MEPs were not affected, thus indicating sufficient collateral blood supply to maintain spinal cord integrity. Nevertheless, preoperative knowledge of SA-AKA location is of importance, because in 32% of patients, spinal cord function was dependent on this supplier. Revascularization of the SA-AKA can thereby reverse spinal cord dysfunction.

Aged↗

Magnetic resonance angiography of collateral vessel growth in a rabbit femoral artery ligation model.

Collateral vessel growth was visualized in a rabbit femoral artery ligation model by serial contrast-enhanced magnetic resonance angiography (MRA) at 1.5 T in comparison with X-ray angiography (XRA). XRA and MRA were performed directly after femoral artery ligation (day 0+) and after 7 and 21 days. XRA (in-plane resolution, 0.3x0.3 mm) was performed with arterial catheterization for fast injection of iodinated contrast agent just proximal to the aortic bifurcation. MRA (in-plane, 0.6x0.6 mm) was performed at 1.5 T with a five-element phased-array coil and slow injection of gadolinium-based MR contrast agent into an ear vein. Collateral vessel scores on two-dimensional XRA projections and on three-dimensional digitally subtracted rotational MRA maximum intensity projections were obtained by two observers and compared. Collateral vessel counts and minimal detectable vessel diameters for MRA and XRA were combined in a computational flow model to interpret differences in spatial detection limits between imaging modalities in terms of flow. Collateral vessel scores were significantly higher in the ligated limb at day 7 (P < 0.05) and more so at day 21 (P < 0.001), in comparison with day 0+ or in the non-ligated control limb on both XRA and MRA. Significantly more (smaller) vessels were visualized with XRA than with MRA, particularly on day 21 (P < 0.05). Inter-observer agreement was high for both XRA (kappa = 0.82) and MRA (kappa = 0.78). The flow model showed that collateral vessels with diameters > 0.3 mm scored by XRA as well as MRA represent nearly 100% of the total blood flow, whereas smaller (0.1-0.3 mm diameter) vessels that can only be detected with XRA contribute little to the blood flow. Serial contrast-enhanced MRA can non-invasively visualize sub-millimeter collateral vessels that represent nearly 100% of the restored blood flow, in a femoral artery ligation model.

Animals↗

Evaluation of Gd(III)DTPA-terminated poly(propylene imine) dendrimers as contrast agents for MR imaging.

Different generations of Gd(III)DTPA-terminated poly(propylene imine) dendrimers {G1 [n = 4 Gd(III) ions per molecule], G3 (n = 16) and G5 (n = 64)} and reference Gd(III)DTPA complex [G0 (n = 1)] were characterized in terms of (i) longitudinal (r1) and transverse (r2) relaxivities in mouse blood plasma, (ii) concentration detection limits in vitro and (iii) in vivo contrast-enhanced MR imaging (CE-MRI) in mice at 1.5 T. Serial and dynamic CE-MRI were performed to monitor the distribution of MRI contrast agent in the heart, arteries, renal system, liver, spleen, bladder and tumor periphery. The relaxivities increased non-linearly with molecular weight (for G0 ionic r1 = 8.1 mM(-1) s(-1) and ionic r2 = 8.6 mM(-1) s(-1) to G5 19.3 and 25.0, respectively). The minimal detectable dendrimer concentration was more than two orders of magnitude lower for G5 (8.1 x 10(-8) M) than for G0 (3.1 x 10(-5) M). Sub-millimeter-sized blood vessels were well visualized with serial CE-MRI with each contrast agent. Dynamic CE-MRI showed timely renal clearance for all contrast agents, but a stronger and a prolonged blood signal enhancement for the higher generations of the dendritic contrast agent. Moreover, G0 and G1 showed a rapid tumor wash-in and wash-out, whereas G3 and G5 displayed a more gradual and prolonged tumor wash-in. In conclusion, both G0 and dendritic contrast agents G1, G3 and G5 are well suited for non-tissue-specific MRI of sub-millimeter-sized blood vessels and evaluating tumor microcirculatory characteristics in mice. Higher generations of dendritic contrast agents display lower concentration detection limits, which suggests their future use for molecular imaging.

Animals↗

Peripheral arterial disease: clinical and cost comparisons between duplex US and contrast-enhanced MR angiography--a multicenter randomized trial.

PURPOSE: To prospectively determine the clinical and economic consequences of replacing duplex ultrasonography (US) with contrast material-enhanced magnetic resonance (MR) angiography for the initial imaging work-up of patients with peripheral arterial disease (PAD). MATERIALS AND METHODS: This randomized multicenter study was approved by the institutional review board of each hospital, and all patients signed written informed consent prior to randomization. Patients with PAD who needed to undergo imaging work-up and who had an ankle-brachial pressure index (ABPI) of less than 0.90 were recruited by vascular surgeons between January 2002 and September 2003. Patients were randomly assigned to undergo contrast-enhanced MR angiography or duplex US. The primary outcome measure was cost. Secondary outcome measures included therapeutic confidence, changes in disease severity, and changes in quality of life (QOL) assessed during 6 months of follow-up. Indicators for disease severity were based on the Rutherford classification, treadmill walking distance, ABPI at rest, and ABPI after exercise. QOL was assessed with the Rating Scale, Short Form 36, EuroQol-5D, and VascuQol questionnaires. The cost of (additional) imaging procedures, therapeutic interventions, and outpatient visits were calculated from a hospital perspective (ie, all costs incurred inside the hospital were estimated, including physician costs). Data were evaluated by using the Student t test and a multivariable linear regression analysis. RESULTS: At 6 months, 352 patients (239 [68%] men, 113 [32%] women; mean age, 65 years) were analyzed. The use of contrast-enhanced MR angiography versus duplex US reduced the number of additional vascular imaging procedures by 42%; contrast-enhanced MR angiography was also associated with higher therapeutic confidence. Diagnostic costs for contrast-enhanced MR angiography were 167 euros (186 dollars) higher than those for duplex US (P < .001). No statistically significant differences were found for total cost, changes in disease severity, or changes in QOL between patients examined with duplex US and those examined with contrast-enhanced MR angiography (P > .05). CONCLUSION: Replacing duplex US with contrast-enhanced MR angiography for the initial imaging work-up of patients with PAD reduces the need for additional imaging, although diagnostic costs are higher.

Aged↗

Dynamic contrast-enhanced magnetic resonance imaging of radiation therapy-induced microcirculation changes in rectal cancer.

PURPOSE: Dynamic contrast-enhanced T1-weighted magnetic resonance imaging (DCE-MRI) allows noninvasive evaluation of tumor microvasculature characteristics. This study evaluated radiation therapy related microvascular changes in locally advanced rectal cancer by DCE-MRI and histology. METHODS AND MATERIALS: Dynamic contrast-enhanced-MRI was performed in 17 patients with primary rectal cancer. Seven patients underwent 25 fractions of 1.8 Gy radiation therapy (RT) (long RT) before DCE-MRI and 10 did not. Of these 10, 3 patients underwent five fractions of 5 Gy RT (short RT) in the week before surgery. The RT treated and nontreated groups were compared in terms of endothelial transfer coefficient (K(PS), measured by DCE-MRI), microvessel density (MVD) (scored by immunoreactivity to CD31 and CD34), and tumor cell and endothelial cell proliferation (scored by immunoreactivity to Ki67). RESULTS: Tumor K(PS) was 77% (p = 0.03) lower in the RT-treated group. Histogram analyses showed that RT reduced both magnitude and intratumor heterogeneity of K(PS) (p = 0.01). MVD was significantly lower (37%, p = 0.03) in tumors treated with long RT than in nonirradiated tumors, but this was not the case with short RT. Endothelial cell proliferation was reduced with short RT (81%, p = 0.02) just before surgery, but not with long RT (p > 0.8). Tumor cell proliferation was reduced with both long (57%, p < 0.001) and short RT (52%, p = 0.002). CONCLUSION: Dynamic contrast-enhanced-MRI-derived K(PS) values showed significant radiation therapy related reductions in microvessel blood flow in locally advanced rectal cancer. These findings may be useful in evaluating effects of radiation combination therapies (e.g., chemoradiation or RT combined with antiangiogenesis therapy), to account for effects of RT alone.

Cell Proliferation↗

Imaging peripheral arterial disease: a randomized controlled trial comparing contrast-enhanced MR angiography and multi-detector row CT angiography.

PURPOSE: To prospectively evaluate clinical utility, patient outcomes, and costs of contrast material-enhanced magnetic resonance (MR) angiography compared with multi-detector row computed tomographic (CT) angiography for initial imaging in the diagnostic work-up of patients with peripheral arterial disease. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. Patients referred for diagnostic imaging work-up to evaluate the feasibility of a revascularization procedure were randomly assigned to undergo either MR angiography or CT angiography. Clinical utility was assessed with therapeutic confidence (scale of 0-10) at initial imaging and with the need for additional imaging. Patient outcomes included ankle-brachial index, maximum walking distance, change in clinical status, and health-related quality of life. Actual diagnostic and therapeutic costs were calculated from the hospital perspective. Differences between group means were calculated with unpaired t tests and 95% confidence intervals. RESULTS: A total of 157 consecutive patients with peripheral arterial disease were prospectively randomized to undergo MR angiography (51 men, 27 women; mean age, 63 years) or CT angiography (50 men, 29 women; mean age, 64 years). For one of the 78 patients in the MR group, no data were available. Mean confidence for MR angiography (7.7) was slightly lower than that for CT angiography (8.0, P = .8). During 6 months of follow-up, 13 patients in the MR group compared with 10 patients in the CT group underwent additional vascular imaging (P = .5). Although not statistically significant, there was a consistent trend of less improvement in the MR group across all patient outcomes. The average cost for diagnostic imaging was 359 ($438) higher in the MR group than in the CT group (95% confidence interval: 209, 511 [$255, $623]; P < .001). Therapeutic costs were higher in the MR group, but the difference was not significant. CONCLUSION: The results suggest that CT angiography has some advantages over MR angiography in the initial evaluation of peripheral arterial disease.

Aged↗

Cost analysis of procedures related to the management of renal artery stenosis from various perspectives.

To determine the costs associated with the diagnostic work-up and percutaneous revascularization of renal artery stenosis from various perspectives. A prospective multicenter comparative study was conducted between 1998 and 2001. A total of 402 hypertensive patients with suspected renal artery stenosis were included. Costs were assessed of computed tomography angiography (CTA), magnetic resonance angiography (MRA), digital subtraction angiography (DSA), and percutaneous revascularization. From the societal perspective, DSA was the most costly (euro 1,721) and CTA the least costly diagnostic technique (euro 424). CTA was the least costly imaging procedure irrespective of the perspective used. The societal costs associated with percutaneous renal artery revascularization ranged from euro 2,680 to euro 6,172. Overall the radiology department incurred the largest proportion of the total societal costs. For the management of renal artery stenosis, performing the analysis from different perspectives leads to the same conclusion concerning the least costly diagnostic imaging and revascularization procedure.

Adolescent↗

Dynamic contrast-enhanced MR imaging kinetic parameters and molecular weight of dendritic contrast agents in tumor angiogenesis in mice.

PURPOSE: To evaluate the relationship between dynamic contrast agent-enhanced magnetic resonance (MR) imaging-derived kinetic parameters and contrast agents of equal chemical composition and configuration but with different molecular weights in a tumor angiogenesis model. MATERIALS AND METHODS: This study was approved by the ethical review committee. Maintenance and care of animals was in compliance with guidelines set by the institutional animal care committee. Dynamic contrast-enhanced MR imaging was performed with dendritic contrast agents in 16 mice with tumor xenografts; mice were placed in groups of four for each molecular weight of the contrast agent. The magnitude and spatial distribution of kinetic parameters (transfer coefficient [K(PS)] and plasma fraction [f(PV)]) were compared with molecular weight of the contrast agent by determining the Spearman correlation coefficient (r) and the quantitative relationship between the endothelial K(PS) and molecular weight. RESULTS: Inverse relationships between molecular weight of contrast agent and K(PS) and f(PV) of tumor rim (r = -0.8, P < .001 and r = -0.5, P = .04, respectively) and core (r = -0.7, P = .004 and r = -0.6, P = .01, respectively) were observed. The quantitative relationship between K(PS) and molecular weight (MW) was K(PS) = 0.4/MW(0.44). A decreasing stepwise pattern in f(PV) was noted between contrast agents with low (0.7- and 3.0-kDa) molecular weight and those with high (12- and 51-kDa) molecular weight. CONCLUSION: Macromolecular permeability is best measured with high-molecular-weight contrast agents; endothelial K(PS) values measured with low-molecular-weight contrast agents incorporate tissue perfusion and permeability and demonstrate heterogeneous microcirculatory flow.

Animals↗

Contrast-enhanced peripheral MR angiography using SENSE in multiple stations: feasibility study.

PURPOSE: To investigate if the use of parallel imaging is feasible and beneficial for peripheral contrast-enhanced magnetic resonance angiography (CE-MRA). MATERIALS AND METHODS: A total of 19 consecutive patients underwent peripheral CE-MRA using SENSE with two-fold reduction in the upper and lower leg stations. Conventional nonaccelerated imaging using constant level appearance (CLEAR) was used in the aortoiliac station. The findings were compared with those in a similar patient group that underwent peripheral CE-MR angiography using our standard imaging protocol without SENSE. Intraarterial digital subtraction angiography (IA-DSA) was used as the standard of reference. Lower extremity vessels were divided into anatomic segments (aortoiliac, upper legs, lower legs) for review. In each anatomic segment signal- and contrast-to-noise ratios (SNR, CNR), venous contamination, subjective image quality, as well as sensitivity and specificity, were determined for both patient groups. RESULTS: SNR and CNR improved significantly for the aortoiliac and upper leg segments (all P-values < or = 0.001). Small reductions were seen in the frequency of disturbing venous enhancement (P = not significant). There were no significant differences with regards to subjective image quality or diagnostic accuracy (all P > 0.3). Overall sensitivity and specificity in the SENSE group were 81% and 95%, respectively. For the non-SENSE group, these values were 79% and 96%, respectively. CONCLUSION: Preliminary results show that three-station peripheral CE-MRA using a full length peripheral arterial coil in combination with SENSE in the upper and lower leg stations is feasible and useful for further optimization of peripheral MRA. Using SENSE allows for routine, high-quality depiction of the entire peripheral vascular tree including the pedal arch. Higher SENSE factors are needed for further optimization.

Aged↗

Comparison of 0.5-M Gd-DTPA with 1.0-M gadobutrol for magnetic resonance angiography of the supplying arteries of the spinal cord in thoracoabdominal aortic aneurysm patients.

PURPOSE: To prospectively compare 0.5-M gadopentetate dimeglumine (Gd-DTPA) with 1.0-M gadobutrol for contrast-enhanced magnetic resonance angiography (CE-MRA) of the blood supplying arteries of the spinal cord in patients referred for open surgical repair of a thoracoabdominal aortic aneurysm (TAAA). MATERIALS AND METHODS: A total of 11 patients with a TAAA underwent two three-dimensional CE-MRA exams of the aorta, segmental arteries (SAs), artery of Adamkiewicz (AKA), and anterior spinal artery (ASA). Imaging was performed on two separate occasions using Gd-DTPA and gadobutrol as contrast agents at 0.3 mmol/kg. Images were evaluated by measuring signal-to-noise (SNR) and contrast-to-noise (CNR) ratios and were judged for different image quality criteria by two blinded observers. RESULTS: In all patients both CE-MRA exams were of sufficient image quality to detect the AKA and ASA. No significant differences in SNR and CNR were observed between the two contrast agents. According to the observers, no significant differences in subjective image quality were found. CONCLUSIONS: Using both contrast agents it was possible to visualize the ultrasmall spinal cord arteries in all cases. The use of the 1.0-M contrast agent did not improve image quality of CE-MRA images of the blood supplying arteries of the spinal cord compared to the 0.5-M contrast agent.

Aged↗

Comparison of generic and disease-specific questionnaires for the assessment of quality of life in patients with peripheral arterial disease.

OBJECTIVE: This study compared the ability of generic and disease-specific questionnaires to assess quality of life (QOL) at baseline and to detect change in QOL after treatment in patients with peripheral arterial disease (PAD). METHODS: This prospective multicenter trial recruited 514 patients with PAD who needed an imaging workup and had an ankle brachial pressure index of less than 0.90. Patients with severe comorbidity were excluded, leaving a study population of 450 patients. Patients completed two generic questionnaires, the Short Form 36 (SF-36) and the European Quality of Life 5D (EuroQol-5D), and one disease-specific questionnaire, the Vascular Quality of Life (VascuQol) at baseline and after 6 months of follow-up. Rutherford classification and treadmill walking distance were determined at baseline and after 6 months of follow-up and were considered indicators of disease severity. Receiver operating characteristic (ROC) curves and areas under the curves (AUCs) were used to evaluate each of the three questionnaires for its ability to discriminate between severe and mild disease at baseline and to discriminate between a large and small change in disease severity after follow-up. The underlying assumption was that disease severity is a major determinant of QOL. This implies that the validity of a QOL questionnaire is reflected by its ability to discriminate between mildly and severely diseased patients. RESULTS: At baseline, 443 patients and after follow-up, 386 patients completed questionnaires. At baseline, no significant ( P >.05) differences were observed among AUCs for the total scores of the three questionnaires, indicating that all three questionnaires assessed the disease severity equally well. After follow-up, the AUCs for the VascuQol were significantly higher than the AUCs for the SF-36 and EuroQol-5D with respect to detection of improvement in Rutherford classification ( P < .05), indicating that change in disease severity after follow-up was best detected by the VascuQol. CONCLUSION: The VascuQol is the preferred questionnaire as outcome measure for QOL in future trials and clinical follow-up of patients with PAD.

Aged↗

Mechanisms of adenosine-induced renal vasodilatation in hypertensive patients.

BACKGROUND: Adenosine is an endogenous nucleoside with potent vasodilatory capacities, released under ischaemic conditions in particular. Its mechanisms of action, however, remain elusive. OBJECTIVE: To evaluate the role of adenosine, using a non-selective purinergic receptor antagonist, and the possible involvement of nitric oxide in this mechanism. In addition, the production of renin and catecholamines was studied during infusion of adenosine, caffeine, or both. METHODS: Thirty-three hypertensive patients who underwent diagnostic renal angiography received intrarenal infusions of adenosine either alone or in combination with caffeine or the nitric oxide synthase inhibitor, N-monomethyl-L-arginine (L-NMMA). The effects on renal blood flow (RBF) were assessed by the xenon-133 washout technique and both arterial and renal venous blood samples were taken for measurement of renin and catecholamine concentrations. Intra-arterial blood pressure and heart rate were monitored continuously. RESULTS: Adenosine induced a dose-dependent vasodilatation. Caffeine alone did not change RBF, but shifted the dose-response curve of adenosine to the right during concomitant infusion of caffeine. RBF during combined infusion of L-NMMA and adenosine was not different from that during adenosine alone, but the decrease in renal vascular resistance was less pronounced during this combination. Renin secretion did not change during the infusion of either adenosine alone or adenosine in combination with caffeine. Catecholamine concentrations also did not change during any of the experiments. CONCLUSIONS: Adenosine induces vasodilatation in the human hypertensive kidney and this effect is mediated by the adenosine receptor. Nitric oxide plays, at most, a minor part in the adenosine-induced vasodilatation. Furthermore, renin secretion is not affected by adenosine and caffeine.

Adenosine↗

Accuracy of semiautomated analysis of 3D contrast-enhanced magnetic resonance angiography for detection and quantification of aortoiliac stenoses.

OBJECTIVES: We sought to compare reproducibility and accuracy of semiautomated stenosis detection and quantification in 3D contrast-enhanced magnetic resonance angiography (CE-MRA) images with conventional evaluation of 3D CE-MRA in patients with peripheral arterial disease (PAD) by using intra-arterial digital subtraction angiography (IA-DSA) as standard of reference. METHODS: Twenty-five patients with PAD underwent CE-MRA and IA-DSA. Three blinded observers independently evaluated CE-MRA datasets for stenoses in the aortoiliac region using semiautomated computer analysis. Semiautomated measurements were compared with conventional measurements of stenosis on CE-MRA datasets, as measured by 3 other independent observers blinded to all other measurements. Interobserver agreement was quantified using kappa (kappa) and intraclass correlation coefficients (ICCs). Sensitivity and specificity were determined for both semiautomated and conventional measurements. RESULTS: Semiautomated measurements were successful in 124 of the 125 arterial segments. The sensitivity of semiautomated measurements was 89% for all observers; specificity varied between 87% and 89%. For conventional measurements of CE-MRA, sensitivity varied between 79% and 86%; specificity was between 86% and 96%. There was good interobserver agreement between all readers for semiautomated measurements (combined kappa for all 3 observers together = 0.78; ICC = 0.82), as well as for conventional measurements (combined kappa = 0.70; and ICC = 0.83). Differences between ICCs, combined kappa values, and accuracy of both measurements were not significant (all P > 0.05). CONCLUSION: Semiautomated analysis of aortoiliac 3D CE-MRA has the same high accuracy for detection and quantification of stenoses as conventional readings of CE-MRA.

Aged↗

Assessment of human atherosclerotic carotid plaque components with multisequence MR imaging: initial experience.

PURPOSE: To prospectively determine, by using a stepwise logistic regression model, the optimal magnetic resonance (MR) weighting (ie, pulse sequence) combinations for plaque assessment and corresponding cutoff values of relative signal intensities (rSIs). MATERIALS AND METHODS: Institutional review board approval and patient consent were obtained. Eleven patients (seven men, four women; mean age +/- standard deviation, 68 years +/- 4) with symptomatic carotid disease and stenosis of more than 70% were investigated at MR imaging before carotid endarterectomy. The MR images were matched with histologic features of the endarterectomy specimens (reference standard). The rSIs (compared with that of muscle tissue) from regions of interest were assessed qualitatively and semiquantitatively. For all major components (calcification, lipid core, intraplaque hemorrhage, and fibrous tissue), optimal cutoff points for the rSIs were determined for five MR weightings by means of receiver operating characteristic curves. The best predicting combinations of these five dichotomized MR weightings were selected by means of stepwise logistic regression analysis. The potential sensitivity and specificity of MR imaging for vulnerable plaque with hemorrhage and/or lipid core were determined. RESULTS: The same optimal MR weighting combinations for identifying the four plaque components were found with qualitative and semiquantitative analysis. Sensitivity and specificity for vulnerable plaque were 93% (95% confidence interval: 77%, 99%) and 96% (95% confidence interval: 86%, 100%), respectively, for the qualitative analysis and 76% (95% confidence interval: 56%, 90%) and 100% (95% confidence interval: 93%, 100%) for the semiquantitative analysis. CONCLUSION: This study demonstrates the potential of a systematic approach of atherosclerotic plaque assessment with multisequence MR imaging by using the information provided from five different MR weightings in a stepwise logistic regression model.

Aged↗

Rectal cancer: MR imaging in local staging--is gadolinium-based contrast material helpful?

PURPOSE: To determine retrospectively whether addition of gadolinium-enhanced T1-weighted magnetic resonance (MR) sequence to T2-weighted turbo spin-echo (SE) MR imaging is valuable for preoperative assessment of T stage and circumferential resection margin in patients with primary rectal cancer. MATERIALS AND METHODS: Local institutional review board approved study and waived informed patient consent. Eighty-three patients with operable primary rectal cancer underwent preoperative MR imaging. Retrospectively, two observers independently scored T2-weighted turbo SE MR images and, in a second reading, T2-weighted images combined with gadolinium-enhanced T1-weighted turbo SE MR images for tumor penetration through rectal wall and tumor extension into mesorectal fascia. A confidence level scoring system was used, and receiver operating characteristic (ROC) curves were generated. Histologic findings were standard of reference. Difference in performance of T2-weighted and combined T2-weighted plus gadolinium-enhanced T1-weighted sequences was analyzed by comparing corresponding areas under ROC curves (A(z)) for each observer. Interobserver agreement was calculated by using linear weighted kappa statistics. RESULTS: Addition of contrast-enhanced T1-weighted to T2-weighted MR imaging did not significantly improve diagnostic accuracy for prediction of tumor penetration through rectal wall (A(z) of T2-weighted vs T2-weighted plus T1-weighted images for observer 1, 0.740 vs 0.764; observer 2, 0.856 vs 0.768) and tumor extension into mesorectal fascia (A(z) for observer 1, 0.962 vs 0.902; observer 2, 0.902 vs 0.911). Diagnostic performance (A(z)) of MR and interobserver agreement were high for prediction of tumor extension into mesorectal fascia (kappa = 0.61, 0.74) but only moderate for penetration through rectal wall (kappa = 0.47, 0.45). CONCLUSION: Gadolinium-enhanced MR sequences did not improve diagnostic accuracy for assessment of tumor penetration through rectal wall and tumor extension into mesorectal fascia.

Adult↗

Accuracy of computed tomographic angiography and magnetic resonance angiography for diagnosing renal artery stenosis.

BACKGROUND: Timely, accurate detection of renal artery stenosis is important because this disorder may be a potentially curable cause of hypertension and renal impairment. OBJECTIVE: To determine the validity of computed tomographic angiography (CTA) and magnetic resonance angiography (MRA) compared with digital subtraction angiography (DSA) for detection of renal artery stenosis. DESIGN: Prospective multicenter comparative study conducted from 1998 to 2001. Two panels of 3 observers judged CTA and MRA image data and were blinded to all other results. Digital subtraction angiography images were evaluated by consensus. SETTING: 3 large teaching hospitals and 3 university hospitals in the Netherlands. PATIENTS: 402 hypertensive patients with suspected renal artery stenosis were included. A group of 356 patients who underwent all 3 diagnostic tests was used for analysis. MEASUREMENTS: Reproducibility was assessed by calculating interobserver agreement. Diagnostic performance was evaluated in terms of sensitivity, specificity, and other diagnostic variables. Atherosclerotic stenoses of 50% or greater and fibromuscular dysplasia were considered clinically relevant. RESULTS: Twenty percent of patients who underwent all 3 tests had clinically relevant renal artery stenosis. Moderate interobserver agreement was found, with kappa values ranging from 0.59 to 0.64 for CTA and 0.40 to 0.51 for MRA. The combined sensitivity and specificity were 64% (95% CI, 55% to 73%) and 92% (CI, 90% to 95%) for CTA and 62% (CI, 54% to 71%) and 84% (CI, 81% to 87%) for MRA. LIMITATIONS: Eighteen percent of the patients were included nonconsecutively. Digital subtraction angiography may be an imperfect reference test. CONCLUSION: Computed tomographic angiography and MRA are not reproducible or sensitive enough to rule out renal artery stenosis in hypertensive patients. Therefore, DSA remains the diagnostic method of choice. *For a list of the other investigators and research coordinators who participated in RADISH, see the Appendix.

Adult↗

Spinal cord feeding arteries at MR angiography for thoracoscopic spinal surgery: feasibility study and implications for surgical approach.

PURPOSE: To prospectively investigate the feasibility of contrast material-enhanced magnetic resonance (MR) angiography for visualization of the spinal vasculature in patients referred for video-assisted thoracoscopic surgical treatment of a thoracic herniated disk and to prospectively assess the influence of preoperative imaging of the spinal vasculature on the choice of surgical approach. MATERIALS AND METHODS: Eight patients (three men and five women; mean age, 58 years; range, 42-83 years) with a thoracic herniated disk underwent contrast-enhanced MR angiography of the thoracoabdominal aorta and posterior branches. Imaging was performed with three-dimensional first-pass contrast-enhanced MR angiographic technique and a triple dose of gadolinium-based contrast agent. Images were analyzed by two observers in consensus to localize the Adamkiewicz artery (AKA) and its connections to the aorta and the anterior spinal artery (ASA). This information was used to determine any change in surgical approach. RESULTS: In all eight patients, the AKA, the ASA, and the connections with the aorta were identified. The AKA originated between T9 and L2 in all patients and derived from the left side of the aorta in 75% (six of eight) of the patients. In three patients in whom the AKA was observed on the left side, the surgical approach was changed to the right side to preserve spinal cord integrity. CONCLUSION: Preoperative imaging of the AKA is feasible with contrast-enhanced MR angiography. Contrast-enhanced MR angiography can be used to image the main feeding arteries of the spinal cord in patients undergoing thoracoscopic spinal surgery, and results can be used to change the side of surgical approach.

Adult↗

In vivo detection of hemorrhage in human atherosclerotic plaques with magnetic resonance imaging.

PURPOSE: To investigate the performance of high-resolution T1-weighted (T1w) turbo field echo (TFE) magnetic resonance imaging (MRI) for the identification of the high-risk component intraplaque hemorrhage, which is described in the literature as a troublesome component to detect. MATERIALS AND METHODS: An MRI scan was performed preoperatively on 11 patients who underwent carotid endarterectomy because of symptomatic carotid disease with a stenosis larger than 70%. A commonly used double inversion recovery (DIR) T1w turbo spin echo (TSE) served as the T1w control for the T1w TFE pulse sequence. The MR images were matched slice by slice with histology, and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the MR images were calculated. Additionally, two readers, who were blinded for the histological results, independently assessed the MR slices concerning the presence of intraplaque hemorrhage. RESULTS: More than 80% of the histological proven intraplaque hemorrhage could be detected using the TFE sequence with a high interobserver agreement (Kappa = 0.73). The TFE sequence proved to be superior to the TSE sequence concerning SNR and CNR, but also in the qualitative detection of intraplaque hemorrhage. The false positive TFE results contained fibrous tissue and were all located outside the main plaque area. CONCLUSION: The present study shows that in vivo high-resolution T1w TFE MRI can identify the high-risk component intraplaque hemorrhage with a high detection rate in patients with symptomatic carotid disease. Larger clinical trials are warranted to investigate whether this technique can identify patients at risk for an ischemic attack.

Aged↗