PubMed Health⌕ Search

Biomedical subjects

José L Pomar

Publications and source records attributed to José L Pomar.

12 recordsLinked to original sources

Hemolysis in mechanical bileaflet prostheses: experience with the Bicarbon valve.

BACKGROUND: Normal functioning mechanical heart valve prostheses are designed to have a certain degree of intrinsic structural regurgitation as a washout mechanism to avoid prosthetic thrombosis. However, intrinsic regurgitation leads to blood cell trauma and hemolysis. Information on hemolysis associated with mechanical bileaflet prostheses is scarce. This study evaluated factors influencing hemolysis in 197 Bicarbon mechanical bileaflet prostheses implanted in 164 patients. METHODS: Serial office interviews, laboratory studies, and echocardiography evaluations were done in the surviving patients. An assay for measuring lactate dehydrogenase activity was developed, and the presence and severity of subclinical hemolysis was determined using reported criteria and analyzed at 1 and 2 years. RESULTS: Hospital mortality was 5.5%. Follow-up was 98.1% complete. No patient had clinically significant or severe subclinical hemolysis. Serum lactate dehydrogenase levels were significantly higher when a paravalvular leak was documented (282 +/- 85 U/L versus 242 +/- 64 U/L; p = 0.0026). Subclinical hemolysis was significantly more frequent after mitral valve (p = 0.001) and double valve replacement (p = 0.001) than after aortic valve replacement, and was unrelated to prosthetic size or to geometric area index, even in those cases with effective orifice area index equal to or less than 0.85 cm2/m2 (p = 0.298). CONCLUSIONS: Mild subclinical hemolysis is frequently associated with normal functioning Bicarbon heart valves. Subclinical hemolysis was significantly influenced by valve position but not by valve size or effective orifice area index and remained stable through time. The magnitude of hemolysis in Bicarbon prostheses compared favorably with that reported for other bileaflet heart valve prostheses.

Adult↗

[Mortality and morbidity in HIV-infected patients undergoing coronary artery bypass surgery: a case control study].

The use of highly active antiretroviral therapy (HAART) in patients with HIV infection has improved survival. This improvement combined with the metabolic effects of treatment has increased cardiovascular risk and the need for cardiac surgery in these patients. We compared morbidity and mortality in HIV-infected patients (cases, n=7) and non-HIV-infected patients (controls, n=21) who underwent isolated coronary artery surgery between 1997 and 2004. The durations of extracorporeal circulation and aortic cross-clamping were shorter in HIV-infected patients (P=.002 and P=.014, respectively). The percentage of patients who experienced complications was similar, at 57.1% in both groups, but there was a slightly higher number of complications per patient in non-HIV-infected individuals. The mean length of total hospitalization was greater in HIV-infected patients (27.1 [13.3] versus 8.8 [5.3] days; P=.003), as was that of postoperative hospitalization (18.2 [15.4] vs 7.9 [4.2] days; P=.08). No HIV-infected patient died or needed a repeat cardiac operation. No progression of the HIV infection was observed. Isolated coronary artery surgery in HIV-infected patients produces good results, and there is no increase in morbidity or mortality. Extracorporeal circulation did not influence disease progression.

Adult↗

Cryopreserved mitral homograft in the tricuspid position for infective endocarditis: a valve that can be repaired in the long-term (13 years).

Herein is reported the long-term repair of a cryopreserved mitral homograft in the tricuspid position. A 34-year-old HIV-infected patient underwent tricuspid valve replacement in 1991 with a cryopreserved mitral homograft because of infective endocarditis. Chronic tricuspid regurgitation secondary to repeated endocarditis led to reoperation 13 years later. Mitral valve repair was performed with a rigid ring as there was annular dilatation; the valve tissue was intact. One year later, transthoracic echocardiography showed no tricuspid regurgitation. The cryopreserved mitral homograft is a potentially repairable valve in the long-term.

Adult↗

Comparative evaluation of small-size Sorin Slimline and St. Jude HP heart valve prostheses.

BACKGROUND: The Sorin Slimline aortic valve prosthesis, a modification of the Sorin Bicarbon valve with increased internal orifice diameter and geometric orifice area, may show improved hemodynamic performance when compared with other previous prosthesis, but so far no comparison study has been reported. METHODS: Between May 1999 and March 2002, 80 patients (31 to 81 years of age; mean, 65 years) with a small aortic annulus were randomized to undergo aortic valve replacement with either the Sorin Slimline (n = 40) or St. Jude High Performance (n = 40) valve prosthesis. Clinical and echocardiographic Doppler follow-up was performed at 3 to 4 weeks, and 6 and 12 months postoperatively. RESULTS: One patient died of non-valve-related causes 9 months after operation. Mean and peak pressure gradients at 6 and 12 months in the Sorin Slimline valve were lower than in the St. Jude High Performance valve for both size 19 and 21 mm. Effective orifice area and effective orifice area index were not significantly different. There was a significant (p = 0.0001) reduction in left ventricular mass and left ventricular mass index between preoperative measurements and at 12 months after surgery for both valves, but there was no difference (p = 0.27) between the Sorin Slimline and St. Jude High Performance valve prosthesis at any other follow-up period. Clinical results showed similarly good results with both valves. CONCLUSIONS: No clinically significant difference in the hemodynamics of both valves was appreciated; patients with a Sorin Slimline valve exhibited statistically significantly lower pressure gradients, but the small differences in effective orifice area and effective orifice area index did not reach significance. A significant left ventricular mass regression was observed with both valve models. Both prostheses provided a satisfactory clinical outcome.

Adult↗

Partial clamping of the brachiocephalic trunk for total ascending aorta replacement without circulatory arrest: early and midterm results.

BACKGROUND: The aim of this study was to evaluate in elective patients the early and midterm results of partial clamping of the brachiocephalic trunk (BCT) for total ascending aorta replacement (TAAR) without circulatory arrest. Contraindications to the procedure were BCT/aortic arch calcifications and chronic aortic dissection. METHODS: The right radial artery was cannulated to monitor the systemic pressure after the BCT was partially clamped. A specially designed clamp was applied obliquely to occlude approximately 50% of the BCT and part of the aortic arch. The distal tip of the clamp was positioned in front of the left subclavian artery. From January 2002 to October 2003, 92 patients underwent TAAR. In 62 patients (67.4%), partial clamping of the BCT was used. Twenty of these patients underwent isolated TAAR, 27 underwent aortic valve replacement and TAAR, 11 had a Bentall operation, and 2 had a Cabrol operation. The aortic valve was spared in the remaining 2 patients. The mean (+/- SD) aortic cross-clamping and cardiopulmonary bypass times were 96 +/- 31 minutes and 116 +/- 43 minutes, respectively. RESULTS: Early mortality was 1.6% (1 patient). No cerebrovascular accidents occurred, demonstrating the safety of the technique. The major complications were acute respiratory insufficiency in 2 cases and acute renal failure in 5. The mean follow-up time was 9.0 +/- 6.5 months. The mean 18- month and event-free survival rate was 96.6% +/- 0.9%. CONCLUSION: Partial clamping of the BCT for TAAR without circulatory arrest provides good early and midterm clinical results. Aortic arch clamping is not associated with cerebrovascular accidents.

Aorta↗

Isolated bicuspid pulmonary valve: an unusual finding.

Whilst the pulmonary valve is a tricuspid valve, very few reports exist of bicuspid pulmonary valves, the majority of which are associated with congenital heart disease. Isolated bicuspid valves not associated with congenital abnormalities are even more rare. Herein, the case is described of a 65-year-old man who died from a stroke, and in whom a bicuspid pulmonary valve was found during post-mortem dissection for tissue donation.

Autopsy↗

Staphylococcal postoperative subannular left ventricular false aneurysm.

A 37-year-old male with acute complicated methicillin-sensitive Staphylococcus aureus mitral valve endocarditis underwent urgent valve replacement with a bileaflet prosthesis. The postoperative course was complicated with fever and heart failure. Echocardiography showed a large subannular false aneurysm of the left ventricle. Three weeks later resection and closure of the defect with a patch made from a cryopreserved thoracic aorta homograft were performed. The most significant aspects of this rare complication are commented on.

Acute Disease↗

Long-term results after cardiac surgery in patients infected with the human immunodeficiency virus type-1 (HIV-1).

OBJECTIVES: Assessment of long-term results of immunodeficiency virus type-1 (HIV-1)-infected patients undergoing cardiac surgery. METHODS: Retrospective analysis of profile and outcomes of 31 HIV-1-infected patients (35 operations, 1985-2002). RESULTS: Twenty-seven males and four females (mean age 34.67) in three groups: acute infective endocarditis (AIE) 21 (67.74%), coronary (CAD) 5 (16.13%) and non-infective valvular disease (NIVD) 5 (16.13%). HIV factors: drug addiction (23-74.19%), homosexuality (5-16.12%), heterosexuality (3-9.67%), hemodialysis (1-3.22%). HIV stage: A (17), B (2), C (2) in AIE; A (2), B (3) in CAD and A (3), C (2) in NIVD. Mean preoperative CD4 count was 278 cells/microL (12<200 cells/microL, 38.7%). The most frequent pathogens: S. aureus (52.38%), S. viridans (23.8%), Candida (19.04%). Native valve involved in 22 cases (78.33%) and prostheses in 8 (26.67%); 8.57% were operated in 1980-1985, 14.28% in 1986-1990, 22.85% in 1991-1995 and 54.28% in 1996-2002 with 16 elective (48.17%), 17 urgent (45.71%) and two emergencies (5.71%); mean aortic clamping and cardiopulmonary bypass time 78.9 and 107.47 min. Hospital mortality was 22.58 and 28.57% in AIE. No CAD patient died. Nine patients (37.5%) died between 2 and 171 months (mean 54.5). Mortality was 50% in AIE. CD4 count increased from 185.33 to 396.55 cells/microL (P=0.43) in nine patients on antiretrovirals. Fifteen-year actuarial survival is 58.16% overall and 48.01% for AIE. CONCLUSIONS: There is an increase in HIV-1-infected patients requiring cardiac surgery, a decrease in AIE, however NIVD and CAD increasingly seen. Cardiac surgery did not blunt CD4 response induced by antiretrovirals. The late cause of death were not AIDS-related events.

Adult↗

Port-Access cardiac surgery: from a learning process to the standard.

BACKGROUND: Port-Access surgery has been one of the most innovative and controversial methods in the spectrum of minimally invasive techniques for cardiac operations and has been widely used for the treatment of several cardiac diseases. The technique was introduced in our center to evaluate its efficacy in reproducing standardized results without an additional risk. METHODS: Endovascular cardiopulmonary bypass (CPB) through femoral access and endoluminal aortic occlusion were used in 129 patients for a variety of surgical procedures, all of which were video-assisted. A minimal (4-6 cm) anterior thoracotomy through the fourth intercostal space was used in all cases as the surgical approach. RESULTS: More than 96% of the planned cases concluded as true Port-Access procedures. Mean CBP and crossclamp times were 87.2 min. +/- 51.2 (range of 10-457) and 54.9 min. +/- 30.6 (range of 10-190), respectively. Hospital mortality for the overall group was 1.5%, and mitral valve surgery had a 2.2% hospital death rate. The incidence of early neurological events was 0.7%. Mean extubation time, ICU stay, and total length of hospital stay were 5 hours +/- 6 hrs. (range of 2-32), 12 hours +/- 11.8 hrs. (range of 5-78), and 7 days +/- 7.03 days (range of 1-72), respectively. CONCLUSIONS: Our experience indicates that the Port- Access technique is safe and permits reproduction of standardized results with the use of a very limited surgical approach. We are convinced that this is a superior procedure for certain types of surgery, including isolated primary or redo mitral surgery, repair of a variety of atrial septal defects (ASDs), and atrial tumors. It is especially useful in high-risk patients, such as elderly patients or those requiring reoperation. Simplification of the procedure is nevertheless desirable in order to further reduce the time of operation and to address other drawbacks.

Adolescent↗