PubMed Health⌕ Search

Biomedical subjects

José Luis Rojo-Alvarez

Publications and source records attributed to José Luis Rojo-Alvarez.

6 recordsLinked to original sources

Upport vector machines for nonlinear kernel ARMA system identification.

Nonlinear system identification based on support vector machines (SVM) has been usually addressed by means of the standard SVM regression (SVR), which can be seen as an implicit nonlinear autoregressive and moving average (ARMA) model in some reproducing kernel Hilbert space (RKHS). The proposal of this letter is twofold. First, the explicit consideration of an ARMA model in an RKHS (SVM-ARMA2K) is proposed. We show that stating the ARMA equations in an RKHS leads to solving the regularized normal equations in that RKHS, in terms of the autocorrelation and cross correlation of the (nonlinearly) transformed input and output discrete time processes. Second, a general class of SVM-based system identification nonlinear models is presented, based on the use of composite Mercer's kernels. This general class can improve model flexibility by emphasizing the input-output cross information (SVM-ARMA4K), which leads to straightforward and natural combinations of implicit and explicit ARMA models (SVR-ARMA2K and SVR-ARMA4K). Capabilities of these different SVM-based system identification schemes are illustrated with two benchmark problems.

Algorithms↗

A systematic review of the literature on home monitoring for patients with heart failure.

We conducted a systematic review of the literature for assessing the value of home monitoring for heart failure (HF) patients. The abstracts of 383 articles were read. We excluded those in which either no home monitoring was done or only the technical aspects of the telemedicine application were described. Forty-two studies met the selection criteria. We classified the results into feasibility (technical and institutional) and impact (on the clinical process, on patient health, on accessibility and acceptability of the health system, and on the economy). Evaluating the articles showed that home monitoring in HF patients is viable, given that: (1) it appears to be technically effective for following the patient remotely; (2) it appears to be easy to use, and it is widely accepted by patients and health professionals; and (3) it appears to be economically viable. Furthermore, home monitoring of HF patients has been shown to have a positive impact on: (1) the clinical process, supported by a significant improvement of patient follow-up by adjustment of treatment, diet or behaviour, as well as hospital readmissions and emergency visits reduction; (2) the patient's health, supported by a relevant improvement in quality of life, a reduction of days in hospital, and a decrease in mortality; and (3) costs resulting from the use of health resources.

Aged↗

A noninvasive method for assessing impaired diastolic suction in patients with dilated cardiomyopathy.

BACKGROUND: Diastolic suction is a major determinant of early left ventricular filling in animal experiments. However, suction remains incompletely characterized in the clinical setting. METHODS AND RESULTS: First, we validated a method for measuring the spatio-temporal distributions of diastolic intraventricular pressure gradients and differences (DIVPDs) by digital processing color Doppler M-mode recordings. In 4 pigs, the error of peak DIVPD was 0.0+/-0.2 mm Hg (intraclass correlation coefficient, 0.95) compared with micromanometry. Forty patients with dilated cardiomyopathy (DCM) and 20 healthy volunteers were studied at baseline and during dobutamine infusion. A positive DIVPD (toward the apex) originated during isovolumic relaxation, reaching its peak shortly after mitral valve opening. Peak DIVPD was less than half in patients with DCM than in control subjects (1.2+/-0.6 versus 2.5+/-0.8 mm Hg, P<0.001). Dobutamine increased DIVPD in control subjects by 44% (P<0.001) but only by 23% in patients with DCM (P=NS). DIVPDs were the consequence of 2 opposite forces: a driving force caused by local acceleration, and a reversed (opposed to filling) convective force that lowered the total DIVPD by more than one third. In turn, local acceleration correlated with E-wave velocity and ejection fraction, whereas convective deceleration correlated with E-wave velocity and ventriculo:annular disproportion. Convective deceleration was highest among patients showing a restrictive filling pattern. CONCLUSIONS: Patients with DCM show an abnormally low diastolic suction and a blunted capacity to recruit suction with stress. By raising the ventriculo:annular disproportion, chamber remodeling proportionally increases convective deceleration and adversely affects left ventricular filling. These previously unreported mechanisms of diastolic dysfunction can be studied by using Doppler echocardiography.

Adult↗

Doppler-derived ejection intraventricular pressure gradients provide a reliable assessment of left ventricular systolic chamber function.

BACKGROUND: Ejection intraventricular pressure gradients are caused by the systolic force developed by the left ventricle (LV). By postprocessing color Doppler M-mode (CDMM) images, we can measure noninvasively the ejection intraventricular pressure difference (EIVPD) between the LV apex and the outflow tract. This study was designed to assess the value of Doppler-derived EIVPDs as noninvasive indices of systolic chamber function. METHODS AND RESULTS: CDMM images and pressure-volume (conductance) signals were simultaneously acquired in 9 minipigs undergoing pharmacological interventions and acute ischemia. Inertial, convective, and total EIVPD curves were calculated from CDMM recordings. Peak EIVPD closely correlated with indices of systolic function based on the pressure-volume relationship: peak elastance (within-animal R=0.98; between-animals R=0.99), preload recruitable stroke work (within-animal R=0.81; between-animals R=0.86), and peak of the first derivative of pressure corrected for end-diastolic volume (within-animal R=0.88; between-animals R=0.91). The correlation of peak inertial EIVPD with these indices was also high (all R>0.75). Load dependence of EIVPDs was studied in another 5 animals in which consecutive beats obtained during load manipulation were analyzed. During caval occlusion (40% EDV reduction), dP/dtmax, ejection fraction, and stroke volume significantly changed, whereas peak EIVPD remained constant. Aortic occlusion (40% peak LV pressure increase) significantly modified dP/dtmax, ejection fraction, and stroke volume; a nearly significant trend toward decreasing peak EIVPD was observed (P=0.06), whereas inertial EIVPD was unchanged (P=0.6). EIVPD beat-to-beat and interobserver variabilities were 2+/-12% and 5+/-11%, respectively. CONCLUSIONS: Doppler-derived EIVPDs provide quantitative, reproducible, and relatively load-independent indices of global systolic chamber function that correlate closely with currently available reference methods.

Animals↗

Estimation of the end of ejection in aortic stenosis: an unreported source of error in the invasive assessment of severity.

BACKGROUND: All indices of aortic stenosis (AS) rely on measurements of mean transvalvular pressure gradient (DeltaP) and flow rate. Because the gradient is reversed during late ejection, the late systolic left ventricular (LV)-aortic pressure crossover may be an erroneous landmark of end-ejection. The aortic incisura should be a better reference to calculate indices of AS invasively. METHODS AND RESULTS: The accuracy of the pressure crossover and the incisura to define end-ejection was assessed in a chronic AS experimental model (9 dogs) with the use of an implantable flowmeter and Doppler echocardiography as reference. In 288 hemodynamic recordings analyzed (aortic valve area [AVA]: 0.74+/-0.46 cm2), ejection ended 37+/-29 ms after the pressure crossover but almost simultaneously with the incisura (2+/-17 ms). Pressure crossover error accounted for significant errors in the measurement of DeltaP (95% limits of agreement, +0 to +7 mm Hg) and AVA (-0.1 to +0.2 cm2). These errors were reduced to less than half with the use of the incisura to define end-ejection. Additionally, the agreement with Doppler-derived AS indices was best with use of the incisura. Pressure crossover error was maximal in situations of higher output, moderate orifice narrowing, higher arterial compliance, and lower vascular resistance. In 32 consecutive patients undergoing cardiac catheterization for AS, the pressure crossover induced a clinically important overestimation of the DeltaP from +22 to +50%. Errors in AVA estimation were considerably smaller (-2% to +6%) because of simultaneous and offsetting errors in the measurements of DeltaP and flow. CONCLUSIONS: The aortic incisura and not the second pressure crossover should be used to obtain invasive indices of AS.

Algorithms↗

Noninvasive assessment of ejection intraventricular pressure gradients.

OBJECTIVES: The study was designed to validate in vivo a new method to measure ejection intraventricular pressure gradients (IVPGs) by processing color M-mode Doppler data and to assess the effects of inotropic interventions on IVPGs in the clinical setting. BACKGROUND: In the absence of obstruction, ejection IVPGs cannot be estimated by Doppler using the simplified Bernoulli equation. METHODS: High-fidelity micromanometers were placed in the left ventricle of eight minipigs, and synchronic Doppler images and pressure signals were obtained during different hemodynamic conditions. Twenty healthy volunteers and 20 dilated cardiomyopathy patients were studied at baseline and during esmolol, dobutamine, and atropine infusion (only dobutamine in patients). RESULTS: Excellent agreement was observed between micromanometer and Doppler methods for measuring instantaneous pressure differences among the apex, the mid-cavity, and the outflow tract (R(intraclass) = 0.98, 0.81, 0.76, and 0.98 for the peak, time-to-peak, peak reverse, and time-to-peak reverse values, respectively; n = 810 beats). Error of the noninvasive method was -0.05 +/- 0.25 mm Hg for the peak pressure difference. Parametrical images demonstrated that IVPGs originate mainly in the mid-ventricle and then propagate to the outflow tract. Both the magnitude and the temporal course of IVPGs were different among volunteers and patients. Inotropic interventions induced significant changes in the apex-outflow tract pressure differences in both populations, whereas atropine had no effect on IVPGs. CONCLUSIONS: For the first time, ejection IVPGs can be accurately visualized and measured by Doppler-echocardiography. Important aspects of the dynamic interaction among myocardial performance, load mechanics, and ejection dynamics can be assessed in the clinical setting using this method.

Animals↗