PubMed Health⌕ Search

Biomedical subjects

José M F Moura

Publications and source records attributed to José M F Moura.

5 recordsLinked to original sources

Figure-ground segmentation from occlusion.

Layered video representations are increasingly popular; see [2] for a recent review. Segmentation of moving objects is a key step for automating such representations. Current motion segmentation methods either fail to segment moving objects in low-textured regions or are computationally very expensive. This paper presents a computationally simple algorithm that segments moving objects, even in low-texture/low-contrast scenes. Our method infers the moving object templates directly from the image intensity values, rather than computing the motion field as an intermediate step. Our model takes into account the rigidity of the moving object and the occlusion of the background by the moving object. We formulate the segmentation problem as the minimization of a penalized likelihood cost function and present an algorithm to estimate all the unknown parameters: the motions, the template of the moving object, and the intensity levels of the object and of the background pixels. The cost function combines a maximum likelihood estimation term with a term that penalizes large templates. The minimization algorithm performs two alternate steps for which we derive closed-form solutions. Relaxation improves the convergence even when low texture makes it very challenging to segment the moving object from the background. Experiments demonstrate the good performance of our method.

Algorithms↗

Affine-permutation invariance of 2-D shapes.

Shapes provide a rich set of clues on the identity and topological properties of an object. In many imaging environments, however, the same object appears to have different shapes due to distortions such as translation, rotation, reflection, scaling, or skewing. Further, the order by which the object's feature points are scanned changes, i.e., the order of the pixels may be permuted. Relating two-dimensional shapes of the same object distorted by different affine and permutation transformations is a challenge. We introduce a shape invariant that we refer to as the intrinsic shape of an object and describe an algorithm, BLAISER, to recover it. The intrinsic shape is invariant to affine-permutation distortions. It is a uniquely defined representative of the equivalence class of all affine-permutation distortions of the same object. BLAISER computes the intrinsic shape from any arbitrarily affine-permutation distorted image of the object, without prior knowledge regarding the distortions or the undistorted shape of the object. The critical step of BLAISER is the determination of the shape orientation and we provide a detailed discussion on this topic. The operations of BLAISER are based on low-order moments of the input shape and, thus, robust to error and noise. Examples illustrate the performance of the algorithm.

Algorithms↗

STACS: new active contour scheme for cardiac MR image segmentation.

The paper presents a novel stochastic active contour scheme (STACS) for automatic image segmentation designed to overcome some of the unique challenges in cardiac MR images such as problems with low contrast, papillary muscles, and turbulent blood flow. STACS minimizes an energy functional that combines stochastic region-based and edge-based information with shape priors of the heart and local properties of the contour. The minimization algorithm solves, by the level set method, the Euler-Lagrange equation that describes the contour evolution. STACS includes an annealing schedule that balances dynamically the weight of the different terms in the energy functional. Three particularly attractive features of STACS are: 1) ability to segment images with low texture contrast by modeling stochastically the image textures; 2) robustness to initial contour and noise because of the utilization of both edge and region-based information; 3) ability to segment the heart from the chest wall and the undesired papillary muscles due to inclusion of heart shape priors. Application of STACS to a set of 48 real cardiac MR images shows that it can successfully segment the heart from its surroundings such as the chest wall and the heart structures (the left and right ventricles and the epicardium.) We compare STACS' automatically generated contours with manually-traced contours, or the "gold standard," using both area and edge similarity measures. This assessment demonstrates very good and consistent segmentation performance of STACS.

Algorithms↗

Improving spatiotemporal resolution of USPIO-enhanced dynamic imaging of rat kidneys.

This paper addresses the problem of enhancing spatiotemporal resolution of ultra-small superparamagnetic iron oxide (USPIO)-enhanced dynamic MRI of rat kidneys. To alleviate the limited resolution problem of conventional full-scan Fourier imaging methods, we use a generalized series-based imaging scheme to reduce coverage of kappa-space. Experimental results demonstrate that the generalized series imaging method with basis functions constructed using two references (pre- and post-contrast) can reduce the number of phase encodings measured during the dynamic contrast wash-in process by a factor of 4 with a negligible or minimal loss of image quality. The method is expected to make 3D studies possible using USPIO-enhanced dynamic imaging of rat kidneys, and prove valuable for early detection of renal rejection after kidney transplantation.

Animals↗

In vivo detection of acute rat renal allograft rejection by MRI with USPIO particles.

BACKGROUND: Magnetic resonance imaging (MRI) for non-invasively detecting renal rejection was developed by monitoring the accumulation of macrophages labeled with dextran-coated ultrasmall superparamagnetic iron oxide (USPIO) particles at the rat renal allografts during acute rejection. METHODS: Five groups of male rats with DA-->BN renal allografts and one group with BN-->BN renal isografts were investigated by MRI before, immediately after, and 24 hr after intravenous infusion with different doses of USPIO particles. All infusions were done on post-operative day 4. MRI experiments were carried out in a 4.7-Tesla instrument using a gradient echo sequence. RESULTS: MR signal intensity (MRSI) of the cortex was found to decrease with higher dosages of USPIO particles. In the absence of USPIO infusion, a decrease in MRSI was seen in the medulla region, presumably due to hemorrhage associated with renal graft rejection, while no significant change was observed in the cortex. The optimal dose of USPIO particles for visualizing rejection-associated changes in our rat kidney model appears to be 6 mg Fe/kg body weight. Iron staining results correlated with the MRSI data, indicating that the signal reduction in the MR images was due to the presence of iron. Immunohistochemical results indicated that USPIO particles were mostly taken up by infiltrating macrophages in the rejecting grafts. CONCLUSIONS: Our results suggest that MRI with intravenous administration of dextran-coated USPIO particles appears to be a valuable and promising tool that can be used as a non-invasive and sensitive method to detect graft rejection in renal transplantation.

Acute Disease↗