Forensic chemistry education.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to José R Almirall.
Explore the source record for details and available documents.
Ion mobility spectrometry (IMS) is a rugged, inexpensive, sensitive, field portable technique for the detection of organic compounds. It is widely employed in ports of entry and by the military as a particle detector for explosives and drugs of abuse. Solid phase microextraction (SPME) is an effective extraction technique that has been successfully employed in the field for the pre-concentration of a variety of compounds. Many organic high explosives do not have a high enough vapor pressure for effective vapor sampling. However, these explosives and their commercial explosive mixtures have characteristic volatile components detectable in their headspace. In addition, taggants are added to explosives to aid in detection through headspace sampling. SPME can easily extract these compounds from the headspace for IMS vapor detection. An interface that couples SPME to IMS was constructed and evaluated for the detection of the following detection taggants: 2-nitrotoluene (2-NT), 4-nitrotoluene (4-NT), and 2,3-dimethyl-2,3-dinitrobutane (DMNB). The interface was also evaluated for the following common explosives: smokeless powder (nitrocellulose, NC), 2,4-dinitrotoluene (2,4-DNT), 2,6-dinitrotoluene (2,6-DNT), 2,4,6-trinitrotoluene (2,4,6-TNT), hexahydro-1,3,5-trinitro-s-triazine (RDX), and pentaerythritol tetranitrate (PETN). This is the first peer reviewed report of a SPME-IMS system that is shown to extract volatile constituent chemicals and detection taggants in explosives from a headspace for subsequent detection in a simple, rapid, sensitive, and inexpensive manner.
Gamma-Hydroxybutyric acid (GHB) is a CNS depressant that has been abused recreationally for its purported euphoric and relaxation effects and for the purposes of drug facilitated sexual assault due to its sedative and amnesic effects at higher doses. The dramatic increase in the abuse of GHB and association in criminal investigations over the past decade has created the need for forensic laboratories to develop analytical methods to detect GHB in a variety of matrices. The method developed in this work used solid-phase microextraction (SPME) to extract GHB from aqueous samples followed by on-fiber derivatization and analysis by gas chromatography/mass spectrometry (GC/MS). This method detected GHB in aqueous matrices with good sensitivity, high precision, excellent linearity from 0.01 mg/mL to 0.25 mg/mL, and without the need for sample manipulation that could cause interconversion between GHB and its lactone, GBL. The method was successfully applied for detection of GHB in spiked water and beverage samples.
Laser ablation (LA) is a powerful analytical technique for solid microsampling. Its coupling with ICPMS has been shown to offer good precision and accuracy for the elemental analysis of glass fragments. Fractionation in LA poses one of the major challenges to using this technique for in situ trace elemental profiling of glass evidence. The aim of this work was to study the effect of elemental fractionation on the forensic application of elemental analysis of glass samples by LA-ICPMS. Two different approaches were used to evaluate the fractionation: fractionation index and U/Th ratios. The resulting fractionation index values indicate low fractionation for the majority of elements evaluated, ranging between 0.8 and 1.2. The U/Th ratio suggests a higher fractionation at the beginning of the ablation process. To evaluate whether fractionation affects the quantification of glass samples by LA-ICPMS, a comparison of LA results with solution ICPMS analysis was conducted. The distribution of particle sizes during the ablation under different conditions and laser systems was also measured to evaluate the fractionation. The standard reference materials NIST 612, 610, and 1831 were analyzed in triplicate by both methods (n = 55) along with a set of 10 casework samples originating from different automobiles.
The discrimination potential of Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS) is compared with previously reported solution ICP-MS methods using external calibration (EC) with internal standardization and a newly reported solution isotope dilution (ID) method for the analysis of two different glass populations. A total of 91 different glass samples were used for the comparison study; refractive index and elemental composition were measured by the techniques mentioned above. One set consisted of 45 headlamps taken from a variety of automobiles that represents a range of 20 years of manufacturing dates. A second set consisted of 46 automotive glasses (side windows, rear windows, and windshields) representing casework glass from different vehicle manufacturers over several years. The element menu for the LA-ICP-MS and EC-ICP-MS methods include Mg, Al, Ca, Mn, Ce, Ti, Zr, Sb, Ga, Ba, Rb, Sm, Sr, Hf, La, and Pb. The ID method was limited to the analysis of two isotopes each of Mg, Sr, Zr, Sb, Ba, Sm, Hf, and Pb. Laser ablation analyses were performed with a Q switched Nd:YAG, 266 nm, 6 mJ output energy laser. The laser was used in depth profile mode while sampling using a 50 microm spot size for 50 sec at 10 Hz (500 shots). The typical bias for the analysis of NIST 612 by LA-ICP-MS was less than 5% in all cases and typically better than 5% for most isotopes. The precision for the vast majority of the element menu was determined generally less than 10% for all the methods when NIST 612 was measured (40 microg x g(-1)). Method detection limits (MDL) for the EC and LA-ICP-MS methods were similar and generally reported as less than 1 microg x g(-1) for the analysis of NIST 612. While the solution sample introduction methods using EC and ID presented excellent sensitivity and precision, these methods have the disadvantages of destroying the sample, and also involve complex sample preparation. The laser ablation method was simpler, faster, and produced comparable discrimination to the EC-ICP-MS and ID-ICP-MS. LA-ICP-MS can offer an excellent alternative to solution analysis of glass in forensic casework samples.
Paints and coatings are frequently encountered as types of materials that are submitted to forensic science laboratories as a result of trace evidence transfers. The aim of this study was to develop a method to complement the commonly used techniques in a forensic laboratory in order to better characterize these samples for forensic purposes. A laser ablation method has been used to simultaneously sample several layers directly prior to introduction into an inductively coupled plasma-mass spectrometer for the detection and quantification of the trace metals present in the layer(s). Time-resolved analysis plots displaying the elemental response and quantification of selected metals are compared to associate/discriminate paint samples. Matrix-matched standards were successfully incorporated into the analysis scheme for quantification of lead in the solid paint samples. Preparation of new matrix-matched standards for quantification of additional elements developed for this study are also presented. A sample set of eighteen (18) survey automotive paint samples have been analyzed with the developed method in order to determine the utility of LA-ICP-MS for trace element analysis of paints.
Inductively coupled plasma mass spectrometry (ICP-MS) was used to analyze glass evidence from a case in which a person broke a window in each of 15 vehicles in a parking lot in order to gain entry into the vehicles. The results of the analysis by traditional methods, which measure the properties of color, thickness, density, and refractive index, are also reported. A total of 15 known samples representing the windows on the cars and 42 questioned glass fragments recovered from the suspect and the police vehicle where the suspect was sitting were submitted for analysis. Density comparisons separated one of the known samples into three samples, increasing the number of known samples from 15 to 17. The concentrations of 16 elements were measured for all but three of the samples using an external calibration ICP-MS method with internal standardization. Color assessment (non-instrumental) separated the 17 known samples into two groups, and refractive index measurements resulted in six groups when the Emmons double variation method was used and ten groups when the Glass Refractive Index Measurement 2 (GRIM2) system was used. Elemental analysis, by itself, differentiated all of the known samples from each other and associated four of the known sample fragments with several of the questioned sample fragments. The informing power of RI, density, and elemental analysis comparisons is evaluated and a summary of the case results is reported.
The use of illicit substances for the purpose of drug-facilitated sexual assault (DFSA) poses a significant problem. There has been an increase in public awareness of this problem, and a recent invention in the form of a drink coaster claims to detect whether or not a beverage has been spiked with a so-called date rape drug. A person is instructed to place a drop of the suspect beverage onto two spots of the test, smear gently, and wait until dry. If either spot turns to a darker blue color, then a possible date rape drug has been detected by the coaster test. In an effort to determine the effectiveness of the coasters, various drugs that have been associated with drug-facilitated sexual assault were tested at different concentrations in a variety of common alcoholic and non-alcoholic beverages. It was found that although the coasters do detect the presence of GHB and ketamine, two drugs that have been associated with DFSA, there are limiting factors such as the high concentration of the drugs required, hindrance of the reaction due to beverage matrix, and extensive time requirements for ketamine analysis.