PubMed Health⌕ Search

Biomedical subjects

Joseph C Fanguy

Publications and source records attributed to Joseph C Fanguy.

3 recordsLinked to original sources

Optical fiber humidity sensor based on evanescent-wave scattering.

The phenomenon of evanescent-wave scattering (EWS) is used to design an optical-fiber humidity sensor. Porous solgel silica (PSGS) coated on the surface of a silica optical-fiber core scatters evanescent waves that penetrate the coating layer. Water molecules in the gas phase surrounding the optical fiber can be absorbed into the inner surface of the pores of the porous silica. The absorbed water molecules form a thin layer of liquid water on the inner surface of the porous silica and enhance the EWS. The amount of water absorbed into the PSGS coating is in dynamic equilibrium with the water-vapor pressure in the gas phase. Therefore the humidity in the air can be quantitatively determined with fiber-optic EWS caused by the PSGS coating. The humidity sensor reported here is fast in response, reversible, and has a wide dynamic range. The possible interference caused by EWS to an optical-fiber gas sensor with a reagent-doped PSGS coating as a transducer is also discussed.

Journal Article↗

The analysis of uric acid in urine using microchip capillary electrophoresis with electrochemical detection.

Clinical studies have linked irregular concentrations of uric acid in urine to several diseases. Conventional methods for the measurement of uric acid are however temperature-dependent, expensive, and require labile reagents. The miniaturization of analytical techniques, specifically capillary electrophoresis, offers an ideal alternative for clinical analyses such as uric acid determination. The added benefits include reduced reagent and analyte consumption, decreased maintenance costs, and increased throughput and portability. A microchip capillary electrophoresis-electrochemical system for the analysis of uric acid in urine is described. The poly(dimethylsiloxane) (PDMS)/glass microchip utilizes amperometric detection via an off-chip platinum working electrode. Linear responses from 1 to 165 microM and 15 to 110 microM were found for dopamine and uric acid, respectively. The limit of detection for both compounds was 1 microM. Once characterized, the system was used to measure the concentration of uric acid in a dilute urine sample in less than 30 s. The measured uric acid concentration was verified with the uricase reaction and found to be acceptable. Six additional urine samples were evaluated with the microchip device and the uric acid concentration for each sample was found to be in the expected clinical concentration range.

Dopamine↗

Pulsed amperometric detection of carbohydrates on an electrophoretic microchip.

The first report of pulsed amperometric detection (PAD) on an electrophoretic microchip is presented. A hybrid poly-(dimethylsiloxane)/glass device was coupled with a platinum working electrode for the electrochemical detection of glucose, maltose, and xylose. Under optimized detection conditions, glucose was found to respond linearly from 20 to 500 microM with a measured detection limit of 20 microM. The coupling of PAD with a microchip provides a straightforward approach to the analysis of a wide range of carbohydrates using microfluidics.

Carbohydrates↗