PubMed Health⌕ Search

Biomedical subjects

Joseph F Martinez

Publications and source records attributed to Joseph F Martinez.

2 recordsLinked to original sources

Three-dimensional echo and videocardioscopy-guided atrial septal defect closure.

BACKGROUND: Current real-time three-dimensional echocardiography systems (RT3DE) can provide sufficient visualization to permit atrial septal defect (ASD) closure. However, detailed visualization of small objects inside the heart is still suboptimal because of limited resolution, which is a limitation for clinical application. We evaluate the complementary use of videocardioscopy in image-guided ASD closure. METHODS: In a pig model (n = 5), a 4-mm to 8-mm ASD was created with RT3DE guidance. Defect closure was accomplished with a catheter-based patch-delivery system fixed around the defect with mini-anchors under combined RT3DE and videocardioscopy guidance. The endoscope was inserted into the heart through a custom built port designed to allow visualization in the presence of blood. RESULTS: All ASDs were successfully closed. The combination of RT3DE and videocardioscopy allowed detailed visualization of intracardiac structures, instruments, patch, and mini-anchors. CONCLUSIONS: Beating-heart ASD closure can be achieved with combined RT3DE and videocardioscopy imaging. Use of videocardioscopy provides high-resolution imaging and likely improves safety of the image-guided procedure.

Animals↗

Three-dimensional echo-guided beating heart surgery without cardiopulmonary bypass: atrial septal defect closure in a swine model.

OBJECTIVE: In this study, we tested 3 techniques of atrial septal defect closure under real-time 3-dimensional echocardiography guidance in a swine model. METHODS: The operations were conducted under the sole guidance of a modified real-time 3-dimensional echocardiography guidance system with a x4 matrix transducer (Sonos 7500, Philips Medical Systems, Andover, Mass). Eighteen swine were anesthetized, and after median sternotomy, the echo probe was applied directly to the surface of the right atrium. To create an atrial septal defect, balloon atrial septostomy and atrial septal defect enlargement were performed. Subsequently, 3 different techniques of atrial septal defect closure were attempted: group I, direct suture closure; group II, closure of the atrial septal defect using the Amplatzer device (AGA Medical Corp, Golden Valley, Minn); and group III, patch closure of the atrial septal defect (n = 6 each). RESULTS: Real-time 3-dimensional echocardiography guidance provided sufficient spatial resolution and a satisfactory frame rate to provide a "virtual surgeon's view" of the relevant anatomy during the entire procedure. All atrial septal defects were enlarged, and the mean final size was 8.5 +/- 1.8 mm. Atrial septal defect closure was successfully accomplished with all the 3 surgical techniques examined. In groups I and III, the needles (1-3 sutures) and staples (6-12 staples) penetrated the tissue and patch material consistently, whereas in group III, the Amplatzer atrial septal defect device was easily deployed. There was no incident device/staple embolization or air introduction. Neither intraoperative 2-dimensional color Doppler echocardiography nor postmortem macro-evaluation revealed any residual shunts. CONCLUSIONS: Beating heart atrial septal defect closure under real-time 3-dimensional echocardiographic guidance is feasible and, unlike catheter-based devices, applicable for any type of secundum atrial septal defect.

Animals↗