PubMed Health⌕ Search

Biomedical subjects

Joseph J DeRose

Publications and source records attributed to Joseph J DeRose.

9 recordsLinked to original sources

Antegrade endovascular repair of a coarctation-associated aneurysm through an upper hemi-sternotomy.

Late aneurysm formation is a well-described complication after surgical correction of aortic coarctation. Endovascular repair of such aneurysms avoids the morbidity of conventional reoperative thoracic surgery. We describe a unique case of antegrade endovascular repair of a distal coarctation-associated aneurysm with vascular access acquired through the aortic arch by an upper hemi-sternotomy.

Aged↗

European system for cardiac operative risk evaluation predicts long-term survival in patients with coronary artery bypass grafting.

OBJECTIVE: To evaluate the accuracy of predicting long-term mortality in patients with coronary artery bypass grafting (CABG) by using the European system for cardiac operative risk evaluation (EuroSCORE). METHODS: Medical records of patients with CABG (n=3760) between January 1992 and March 2002 were retrospectively reviewed and their predicted surgical risk was calculated according to the standard (study A) and logistic (study B) EuroSCORE. In study A the patients were divided into six groups: 0-2 (n=610), 3-5 (n=1479), 6-8 (n=1099), 9-11 (n=452), 12-14 (n=103) and >14 (n=17). In study B the patients were divided into seven groups: 0.00-2.00 (n=447), 2.01-5.00 (n=1190), 5.01-10.00 (n=890), 10.01-20.00 (n=686), 20.01-30.00 (n=234), 30.01-60.00 (n=254) and >60.00 (n=59). Long-term survival was obtained by the National Death Index and Kaplan-Meier curves were constructed and compared employing the log-rank test. Multivariate Cox regression analysis was performed in order to control for pre, intra and postoperative factors and adjusted hazard ratios were calculated for standard and logistic EuroSCORE groups. The receiver operating characteristic (ROC) curves were plotted to assess the discrimination ability of the EuroSCORE. RESULTS: In study A there were differences among the six groups in 30-day mortality (0.7%, 1.0%, 3.1%, 4.6%, 13.6% and 23.5%; P<0.001), in major complications (8.5%, 10.4%, 16.2%, 20.4%, 31.1% and 35.3%; P<0.001) as well as in actuarial long-term survival (86.2%, 79.6%, 53.6%, 37.9%, 24.9% and 0% from EuroSCORE 0-2 to >14; P<0.001). In study B there were differences among the seven groups in 30-day mortality (0.9%, 1.1%, 1.2%, 3.6%, 3.4%, 8.7% and 15.3%; P<0.001), major complications (8.5%, 10.1%, 12.1%, 18.4%, 16.2%, 26.0% and 30.5%; P<0.001) as well as in actuarial long-term survival (89.5%, 79.9%, 66.9%, 51.0%, 40.3%, 38.4% and 13.7% from EuroSCORE 0.00-2.00 to >60.00; P<0.001). Multivariate Cox regression analysis confirmed that EuroSCORE (standard or logistic) was a statistically significant predictor for long-term mortality, while the area under the ROC curve was 0.72 for either standard or logistic EuroSCORE. CONCLUSION: The predicted surgical risk in CABG patients as calculated by standard or logistic EuroSCORE is a strong predictor for long-term survival in addition to predicting operative survival for which it was originally designed.

Coronary Artery Bypass↗

Robotically assisted left ventricular epicardial lead implantation for biventricular pacing.

OBJECTIVES: Ventricular resynchronization might be achieved in a minimally invasive fashion using a robotically assisted, direct left ventricular (LV) epicardial approach. BACKGROUND: Approximately 10% of patients undergoing biventricular pacemaker insertion have a failure of coronary sinus (CS) cannulation. Rescue therapy for these patients currently is limited to standard open surgical techniques. METHODS: Ten patients with congestive heart failure (New York Heart Association class 3.4 +/- 0.5) and a widened QRS complex (184 +/- 31 ms) underwent robotic LV lead placement after failed CS cannulation. Mean patient age was 71 +/- 12 years, LV ejection fraction (EF) was 12 +/- 6%, and LV end-diastolic diameter was 7.1 +/- 1.3 cm. Three patients had previous cardiac surgery, and five patients had a prior device implanted. RESULTS: Nineteen epicardial leads were successfully placed on the posterobasal surface of the LV. Intraoperative lead threshold was 1.0 +/- 0.5 V at 0.5 ms, R-wave was 18.6 +/- 8.6 mV, and impedance was 1,143 +/- 261 ohms at 0.5 V. Complications included an intraoperative LV injury and a postoperative pneumonia. Improvements in exercise tolerance (8 of 10 patients), EF (19 +/- 13%, p = 0.04), and QRS duration (152 +/- 21 ms, p = 0.006) have been noted at three to six months follow-up. Lead thresholds have remained unchanged (2.1 +/- 1.4 V at 0.5 ms, p = NS), and a significant drop in impedance (310 +/- 59 ohms, p < 0.001) has been measured. CONCLUSIONS: Robotic LV lead placement is an effective and novel technique which can be used for ventricular resynchronization therapy in patients with no other minimally invasive options for biventricular pacing.

Aged↗

Mediastinal mass evaluation using advanced robotic techniques.

The diagnosis and management of mediastinal masses frequently necessitates biopsy and surgical resection. The use of videothorascopic techniques has broadened the surgeon's ability to evaluate and treat such tumors using a minimally invasive approach. We describe herein the use of the da Vinci Robotic Surgical System for evaluating a mediastinal mass in a young woman.

Adult↗

Totally endoscopic robotic thymectomy for myasthenia gravis.

The current recommendations for treating myasthenia gravis include surgical thymectomy for patients between puberty and 60 years of age. This is a report of a new method for surgical thymectomy using the robotic da Vinci surgical system for a totally endoscopic approach. This new procedure combines the potential advantages of minimally invasive methods with the efficacy of open procedures.

Adult↗

Hypereosinophilic thrombus causing aortic stenosis and myocardial infarction.

Hypereosinophilia can cause severe endomyocardial fibrosis with subsequent restrictive cardiac disease and endocardial lesions. We present a case of a 37-year-old man with known hypereosinophilia, followed with yearly echocardiograms, who presented acutely with myocardial infarction and aortic outflow tract obstruction. At surgery, a broad based eosinophilic thrombus was found that had obstructed the aortic outflow tract. The possibility of the rapid emergence of such obstructive thrombotic lesions in hypereosinophilic syndromes warrants very close echocardiographic surveillance.

Adult↗

Isolated left ventricular ischemia after the Norwood procedure.

Aortic atresia is the most severe variant of hypoplastic left heart syndrome (HLHS), and has been associated with significant mortality after stage I palliation. Coronary artery abnormalities are more prominent in this group of patients, especially in the presence of a patent mitral valve. Herein, we describe a case of isolated left ventricular ischemia after the Norwood procedure in a neonate with hypoplastic left heart syndrome, left ventricular hypertrophy, mitral stenosis, aortic atresia, and anomalous left coronary artery.

Coronary Vessel Anomalies↗

Totally endoscopic atrial septal defect repair with robotic assistance.

BACKGROUND: The development of minimally invasive cardiac surgery has been characterized by the performance of increasingly complex operations through progressively smaller incisions. Computer (robotic) enhancement has emerged as a potential facilitator of these procedures, initially by providing enhanced endoscopic camera control and, more recently, by allowing the manipulation of surgical instruments through limited thoracic incisions. This report describes the next step in this progression, namely the performance of an atrial septal defect (ASD) repair entirely through thoracoscopic port incisions. This represents the first U.S. application of robotic technology for totally endoscopic open-heart surgery. MATERIALS AND METHODS: A 33-year-old woman with a secundum atrial septal defect underwent totally endoscopic repair through four port incisions by means of the Da Vinci (Intuitive Surgical, Mountain View, CA) robotic surgical system. Cardiopulmonary bypass was achieved peripherally (femoral Estech endoaortic balloon cannula; femoral and right internal jugular venous Bio-medicus cannulae). The myocardium was protected with antegrade cold blood cardioplegia delivered through the distal port of the arterial cannula. After port insertion, the entire operation, including pericardiotomy, bicaval occlusion, atriotomy, atrial septopexy, and atrial closure, was performed by computer-aided control of a camera and two instrument arms manipulated by a surgeon seated 15 feet away. The fourth port was used for suction and suture passage by the patient-side assistant. The aortic cross-clamp time was 43 minutes, and the postoperative transesophageal echocardiogram demonstrated normal ventricular function and the absence of interatrial shunting. The patient was extubated on the night of surgery, was ambulatory within 15 hours, and was discharged on the morning of postoperative day 3, 63 hours after the procedure. At 30-day follow-up, the patient was well and without complaints, and transthoracic echocardiogram confirmed the continued absence of interatrial shunting. CONCLUSIONS: Computer-aided robotic surgical technology can be used to perform open-heart procedures with a totally endoscopic approach. The benefits of this approach may include decreased perioperative pain, decreased recovery times, and improved cosmesis and patient acceptance. Clinical trials currently in progress will demonstrate whether this technology will be of reproducible value in the management of patients with intracardiac disease on a larger scale.

Adult↗