A multisite telemammography system for remote management of screening mammography: an assessment of technical, operational, and clinical issues.

OBJECTIVE: This paper describes a high-quality, multisite telemammography system to enable "almost real-time" remote patient management while the patient remains in the clinic. One goal is to reduce the number of women who would physically need to return to the clinic for additional imaging procedures (termed "recall") to supplement "routine" imaging of screening mammography. MATERIALS AND METHODS: Mammography films from current and prior (when available) examinations are digitized at three remote sites and transmitted along with other pertinent information across low-level communication systems to the central site. Images are automatically cropped, wavelet compressed, and encrypted prior to transmission to the central site. At the central site, radiologists review and rate examinations on a high-resolution workstation that displays the images, computer-assisted detection results, and the technologist's communication. Intersite communication is provided instantly via a messaging "chat" window. RESULTS: The technologists recommended additional procedures at 2.7 times the actual clinical recall rate for the same cases. Using the telemammography system during a series of "off-line" clinically simulated studies, radiologists recommended additional procedures at 1.3 times the actual clinical recall rate. Percent agreement and kappa between the study and actual clinical interpretations were 66.1% and 0.315, respectively. For every physical recall potentially avoided using the telemammography system, approximately one presumed "unnecessary" imaging procedure was recommended. CONCLUSION: Remote patient management can reduce the number of women recalled by as much as 50% without performing an unreasonable number of presumed "unnecessary" procedures.

Ambulatory Care Facilities↗

Computerized estimation of the lung volume removed during lung volume reduction surgery.

RATIONALE AND OBJECTIVES: This study was designed to develop an automated method for estimating lung volume removed during lung volume reduction surgery (LVRS) using computed tomography (CT). MATERIALS AND METHODS: The CT examinations of six patients who underwent bilateral LVRS were analyzed in this study. The resected lung tissue (right and left) was weighed during pathologic examination. An automated computer scheme was developed to estimate the lung volume removed using the CT voxel values and lung specimen weight. The computed fraction of lung volume removed was evaluated across a range of simulated surgical planes (ie, other than parallel to the CT image plane) and CT reconstruction kernels, and it was compared with the surgeons' postsurgical estimates. RESULTS: The computed fraction of the lung volume removed during LVRS was linearly correlated with the resected lung tissue weight (Pearson correlation = 0.697, P = .012). The computed fraction of lung volume removed ranged from 12.9% to 51.7% of the total lung volume. The surgeons' postsurgical estimates of lung volume removed ranged from 30% to 33%. The percent difference between the surgeons' estimates and the computed lung volume removed as a percentage of the surgeons' estimates ranged from -72.3% to 57.0% with mean absolute difference of 29.7% (+/-20.7). CONCLUSION: The preliminary findings of this study suggest that the proposed quantitative model should provide an objective measure of lung volume removed during LVRS that may be used to investigate the relationship between lung volume removed and outcome.

Absorptiometry, Photon↗

Multiview-based computer-aided detection scheme for breast masses.

In this study, we developed and tested a new multiview-based computer-aided detection (CAD) scheme that aims to maintain the same case-based sensitivity level as a single-image-based scheme while substantially increasing the number of masses being detected on both ipsilateral views. An image database of 450 four-view examinations (1800 images) was assembled. In this database, 250 cases depicted malignant masses, of which 236 masses were visible on both views and 14 masses were visible only on one view. First, we detected suspected mass regions depicted on each image in the database using a single-image-based CAD. For each identified region (with detection score > or = 0.55), we then identified a matching strip of interest on the ipsilateral view based on the projected distance to the nipple along the centerline. By lowering CAD operating threshold inside the matching strip, we searched for a region located inside the strip and paired it with the original region. A multifeature-based artificial neural network scored the likelihood of the paired "matched" regions representing true-positive masses. All single (unmatched) regions except for those either with very high detection scores (> or = 0.85) or those located near the chest wall that cannot be matched on the other view were discarded. The original single-image-based CAD scheme detected 186 masses (74.4% case-based sensitivity) and 593 false-positive regions. Of the 186 identified masses, 91 were detected on two views (48.9%) and 95 were detected only on one view (51.1%). Of the false-positive detections, 54 were paired on the ipsilateral view inside the corresponding matching strips and the remaining 485 were not, which represented 539 case-based false-positive detections (0.3 per image). Applying the multiview-based CAD scheme, the same case-based sensitivity was maintained while cueing 169 of 186 masses (90.9%) on both views and at the same time reducing the case-based false-positive detection rate by 23.7% (from 539 to 411). The study demonstrated that the new multiview-based CAD scheme could substantially increase the number of masses being cued on two ipsilateral views while reducing the case-based false-positive detection rate.

Algorithms↗

Pulmonary nodule detection with low-dose CT of the lung: agreement among radiologists.

OBJECTIVE: The purpose of our study was to assess relative intra- and interobserver agreement in detecting pulmonary nodules when interpreting low-dose chest CT screening examinations. MATERIALS AND METHODS: Two hundred ninety-three selected low-dose CT examinations of the lung were independently interpreted by three radiologists to detect and classify pulmonary nodules. The data set selected was enriched with examinations depicting pulmonary nodules. A subset of 30 examinations was interpreted twice. All pulmonary nodules greater than 1.0 mm were marked. All nodules greater than 3.0 mm were marked, measured, and scored as to their probability of being benign or malignant. Nodule-based and examination-based relative reviewer agreements were evaluated using percentage of agreement and kappa statistics. Similar assessments were performed on the subset of examinations interpreted twice. RESULTS: The three radiologists identified a total of 470, 729, and 876 pulmonary nodules of which 395, 641, and 778 were rated as noncalcified with some level of suspicion for being malignant. Nodule-based interobserver agreement among the radiologists was poor (highest kappa value in a paired comparison, 0.120). Examination-based agreement was higher (highest kappa value in a paired comparison, 0.458). Intraobserver agreement was higher than interobserver agreement for examination-based agreement (highest kappa = 0.889) but lower for nodule-based agreement (highest kappa = -0.035). Agreement improved as the suspicion of malignancy increased. CONCLUSION: Unaided intra- and interobserver agreement in detecting pulmonary nodules in low-dose CT of the lung is relatively low. Computer-assisted detection may provide the consistency that is needed for this purpose.

Female↗

Performance and reproducibility of a computerized mass detection scheme for digitized mammography using rotated and resampled images: an assessment.

OBJECTIVE: Our objective was to compare the performance and reproducibility of a computer-aided detection (CAD) scheme that uses multiple rotated and resampled images with an in-house-developed CAD scheme (single-image-based) and a commercial CAD product in detecting masses depicted on digitized mammograms. MATERIALS AND METHODS: Ninety-two film mammograms (acquired from 23 patients) were selected. Forty-four mass regions associated with malignancy were visually identified. A commercial CAD system was used to scan and process each image four times, for a total of 368 digitized images depicting 176 mass regions. Images were processed using two CAD schemes developed in our laboratory. One uses the detection results generated from a single image, and the other averages five detection scores generated after processing the originally digitized image and four slightly rotated and resampled images. A region-based analysis was used to compare reproducibility and performance levels among the two in-house schemes and the commercial system. RESULTS: The commercial system detected a total of 98 mass regions (55.7% sensitivity) and 136 false-positive regions (an average of 0.37 per image). Among the detected mass regions, 76 represented 19 regions that were detected on all four scans and 22 represented 10 regions that were not fully reproducible. Eighty-eight false-positive detections represented 22 reproducible detections on all four scans. Our single-image-based scheme identified 87 mass regions and 160 false-positive regions. Seventeen mass regions and 28 false-positive regions were detected on all four scans. The multiple-image-based scheme identified 98 mass regions and 132 false-positive regions. Twenty-three mass regions were detected on all four scans. One hundred twelve of the 132 false-positive regions represented 28 reproducible detections. CONCLUSION: Averaging detection scores from multiple rotated and resampled images generated from a single digitization of a film can reduce variations in detection scores. Our multiple-image-based scheme improved both performance and reproducibility over the single-image-based scheme. The multiple-image-based scheme yielded an overall performance comparable to that of the commercial system but with improved reproducibility.

Breast Neoplasms↗

Computer-aided detection schemes: the effect of limiting the number of cued regions in each case.

OBJECTIVE: We assessed performance changes of a mammographic computer-aided detection scheme when we restricted the maximum number of regions that could be identified (cued) as showing positive findings in each case. MATERIALS AND METHODS: A computer-aided detection scheme was applied to 500 cases (or 2,000 images), including 300 cases in which mammograms showed verified malignant masses. We evaluated the overall case-based performance of the scheme using a free-response receiver operating characteristic approach, and we measured detection sensitivity at a fixed false-positive detection rate of 0.4 per image after gradually reducing the maximum number of cued regions allowed for each case from seven to one. RESULTS: The original computer-aided detection scheme achieved a maximum case-based sensitivity of 97% at 3.3 false-positive detected regions per image. For a detection decision score set at 0.565, the scheme had a 79% (237/300) case-based sensitivity, with 0.4 false-positive detected regions per image. After limiting the number of maximum allowed cued regions per case, the false-positive rates decreased faster than the true-positive rates. At a maximum of two cued regions per case, the false-positive rate decreased from 0.4 to 0.21 per image, whereas detection sensitivity decreased from 237 to 220 masses. To maintain sensitivity at 79%, we reduced the detection decision score to as low as 0.36, which resulted in a reduction of false-positive detected regions from 0.4 to 0.3 per image and a reduction in region-based sensitivity from 66.1% to 61.4%. CONCLUSION: Limiting the maximum number of cued regions per case can improve the overall case-based performance of computer-aided detection schemes in mammography.

Breast Neoplasms↗

Size and morphology of the trachea before and after lung volume reduction surgery.

OBJECTIVE: The purpose of this investigation was to determine the effect of lung volume reduction surgery on measured tracheal features. MATERIALS AND METHODS: Twenty-four male and 19 female patients with emphysema underwent lung volume reduction surgery, pulmonary function testing, and repeated CT. The tracheal air column was segmented from axial images. The sagittal and coronal dimensions of the intrathoracic trachea were determined. Tracheal morphology was quantified using the tracheal (coronal and sagittal dimensions) and circularity indexes. The results were compared with pulmonary function test results. RESULTS: Morphologic appearance of the intrathoracic trachea was consistent before and 3 months after surgery. The group means of the tracheal length, mean area, and volume were 78.60 mm (+/- 16.88 mm), 283.84 mm(2) (+/- 61.47 mm(2)), and 22.59 cm(3) (+/- 7.69 cm(3)), respectively, before surgery and 67.53 mm (+/- 15.78 mm), 309.12 mm(2) (+/- 79.83 mm(2)), and 20.99 cm(3) (+/- 7.27 cm(3)), respectively, after surgery (p < 0.05). Mean tracheal indexes were 0.85 (+/- 0.11) before surgery and 0.82 (+/- 0.04) after surgery (p < 0.01). Mean circularity indexes were 0.91 (+/- 0.03) before surgery and 0.90 (+/- 0.04) after surgery (p < 0.05). The size of the trachea was significantly correlated with lung volume before and after surgery (p < 0.05). The changes in tracheal features and changes in pulmonary function were not correlated (p > 0.05), except for tracheal area (p < 0.05). CONCLUSION: Our data suggest that tracheal dimensions reflect the severity of emphysema as reflected by increased lung volumes. Tracheal features were poor predictors of changes in postsurgical pulmonary function parameters evaluated in this preliminary study.

Female↗

Mandibular kinematics represented by a non-orthogonal floating axis joint coordinate system.

There are many methods used to represent joint kinematics (e.g., roll, pitch, and yaw angles; instantaneous center of rotation; kinematic center; helical axis). Often in biomechanics internal landmarks are inferred from external landmarks. This study represents mandibular kinematics using a non-orthogonal floating axis joint coordinate system based on 3-D geometric models with parameters that are "clinician friendly" and mathematically rigorous. Kinematics data for two controls were acquired from passive fiducial markers attached to a custom dental clutch. The geometric models were constructed from MRI data. The superior point along the arc of the long axis of the condyle was used to define the coordinate axes. The kinematic data and geometric models were registered through fiducial markers visible during both protocols. The mean absolute maxima across the subjects for sagittal rotation, coronal rotation, axial rotation, medial-lateral translation, anterior-posterior translation, and inferior-superior translation were 34.10 degrees, 1.82 degrees, 1.14 degrees, 2.31, 21.07, and 6.95 mm, respectively. All the parameters, except for one subject's axial rotation, were reproducible across two motion recording sessions. There was a linear correlation between sagittal rotation and translation, the dominant motion plane, with approximately 1.5 degrees of rotation per millimeter of translation. The novel approach of combining the floating axis system with geometric models succinctly described mandibular kinematics with reproducible and clinician friendly parameters.

Adult↗

Automated lung segmentation in X-ray computed tomography: development and evaluation of a heuristic threshold-based scheme.

RATIONALE AND OBJECTIVES: To develop and evaluate a reliable, fully-automated lung segmentation scheme for application in X-ray computed tomography. MATERIALS AND METHODS: The automated scheme was heuristically developed using a slice-based, pixel-value threshold and two sets of classification rules. Features used in the rules include size, circularity, and location. The segmentation scheme operates slice-by-slice and performs three key operations: (1) image preprocessing to remove background pixels, (2) computation and application of a pixel-value threshold to identify lung tissue, and (3) refinement of the initial segmented regions to prune incorrectly detected airways and separate fused right and left lungs. RESULTS: The performance of the automated segmentation scheme was evaluated using 101 computed tomography cases (91 thick slice, 10 thin slice scans). The 91 thick cases were pre- and post-surgery from 50 patients and were not independent. The automated scheme successfully segmented 94.0% of the 2,969 thick slice images and 97.6% of the 1,161 thin slice images. The mean difference of the total lung volumes calculated by the automated scheme and functional residual capacity plus 60% inspiratory capacity was -24.7 +/- 508.1 mL. The mean differences of the total lung volumes calculated by the automated scheme and an established, commonly used semi-automated scheme were 95.2 +/- 52.5 mL and -27.7 +/- 66.9 mL for the thick and thin slice cases, respectively. CONCLUSION: This simple, fully-automated lung segmentation scheme provides an objective tool to facilitate lung segmentation from computed tomography scans.

Image Processing, Computer-Assisted↗

Relation of jaw sounds and kinematics visualized and quantified using 3-D computer animation.

The management of jaw pain or temporomandibular disorders (TMD) has been controversial regarding temporomandibular joint (TMJ) sounds and their implication regarding TMD prognosis. 3-D computer animation was used to visualize and quantify the internal mechanics of natural mandibular motion synchronized with TMJ sounds. Mandibular movements of four TMD patients and two healthy subjects were recorded using CCD cameras and reflective markers. Sounds were recorded with electret microphones. Magnetic resonance imaging was used to create 3-D geometric models. Visualization of the internal anatomy, mandibular condyle and glenoid fossa, revealed that the condyle initially rotated within the fossa and then moved out of the fossa along, and well beyond, the articular eminence. Power in the opening sound recordings after the condyle moved out of the fossa was significantly greater than when the condyle was within the fossa (p<0.001). The louder opening sounds were often classified as TMJ clicks, implying that clicks occur after the condyle moves out of the fossa. The 3-D computer animation should help resolve the implication of TMJ sounds regarding TMD prognosis by providing visualization and quantization of the TMJ internal mechanics during sound production.

Adult↗

Integrated density of a lesion: a quantitative, mammographically derived, invariable measure.

A method for quantitatively estimating lesion "size" from mammographic images was developed and evaluated. The main idea behind the measure, termed "integrated density" (ID), is that the total x-ray attenuation attributable to an object is theoretically invariant with respect to the projected view and object deformation. Because it is possible to estimate x-ray attenuation of a lesion from relative film densities, after appropriate corrections for background, the invariant property of the measure is expected to result in an objective method for evaluating the "sizes" of breast lesions. ID was calculated as the integral of the estimated image density attributable to a lesion, relative to surrounding background, over the area of the lesion and after corrections for the nonlinearity of the film characteristic curve. This effectively provides a measure proportional to lesion volume. We computed ID and more traditional measures of size (such as "mass diameter" and "effective size") for 100 pairs of ipsilateral mammographic views, each containing a lesion that was relatively visible in both views. The correlation between values calculated for each measure from corresponding pairs of ipsilateral views were computed and compared. All three size-related measures (mass diameter, effective size, and ID) exhibited reasonable linear relationship between paired views (r2>0.7, P<0.001). Specifically, the ID measures for the 100 masses were found to be highly correlated (r2=0.9, P<0.001) between ipsilateral views of the same mass. The correlation increased substantially (r2=0.95), when a measure with linear dimensions of length was defined as the cube root of ID. There is a high degree of correlation between ID-based measures obtained from different views of the same mass. ID-based measures showed a higher degree of invariance than mass diameter or effective size.

Absorptiometry, Photon↗