Micrometer-sized supported lipid bilayer arrays for bacterial toxin binding studies through total internal reflection fluorescence microscopy.

In this article, we present the use of micron-sized lipid domains, patterned onto planar substrates and within microfluidic channels, to assay the binding of bacterial toxins via total internal reflection fluorescence microscopy. The lipid domains were patterned using a polymer lift-off technique and consisted of ganglioside-populated distearoylphosphatidylcholine:cholesterol supported lipid bilayers (SLBs). Lipid patterns were formed on the substrates by vesicle fusion followed by polymer lift-off, which revealed micron-sized SLBs containing either ganglioside G(T1b) or G(M1). The ganglioside-populated SLB arrays were then exposed to either cholera toxin B subunit or tetanus toxin C fragment. Binding was assayed on planar substrates by total internal reflection fluorescence microscopy down to 100 pM concentration for cholera toxin subunit B and 10 nM for tetanus toxin fragment C. Apparent binding constants extracted from three different models applied to the binding curves suggest that binding of a protein to a lipid-based receptor is influenced by the microenvironment of the SLB and the substrate on which the bilayer is formed. Patterning of SLBs inside microfluidic channels also allowed the preparation of lipid domains with different compositions on a single device. Arrays within microfluidic channels were used to achieve segregation and selective binding from a binary mixture of the toxin fragments in one device. The binding and segregation within the microfluidic channels was assayed with epifluorescence as proof of concept. We propose that the method used for patterning the lipid microarrays on planar substrates and within microfluidic channels can be easily adapted to proteins or nucleic acids and can be used for biosensor applications and cell stimulation assays under different flow conditions.

Bacterial Toxins↗

High spatial resolution observation of single-molecule dynamics in living cell membranes.

Self-organized lipid bilayers together with proteins are the essential building blocks of biological membranes. Membranes are associated with all living systems as they make up cell boundaries and provide basic barriers to cellular organelles. It is of interest to study the dynamics of individual molecules in cell membranes as the mechanism of how biological membranes function at the single molecule remains to be elucidated. In this letter we describe a study in which we incubate rat basophilic leukemia cells with a fluorescently labeled cell membrane component on a surface containing zero-mode waveguides (ZMWs). We used the ZMW to confine fluorescent excitation to an approximately 100-nm region of the membrane to monitor lipid diffusion along the cellular membrane. We showed that confinement with a ZMW largely reduced fluorescent contributions from the cytosolic pool that is present when using a more standard technique such as laser-induced confocal microscopy. We show that optical confinement with ZMWs is a facile way to probe dynamic processes on the membrane surface.

Animals↗

Single molecule studies of quantum dot conjugates in a submicrometer fluidic channel.

A microfluidic and optical system was created for the detection and analysis of single molecules in solution. Fluidic channels with submicrometer dimensions were used to isolate, detect and identify individual quantum dots conjugated with organic fluorophores. The channels were fabricated in fused silica with a 500 nm square cross section. The resulting focal volume of approximately 500 aL reduced fluorescent background and increased the signal to noise ratio of single molecule detection. The channels also enabled the rapid detection of 99% of quantum dots and organic fluorophores traversing the focal volume. Conjugates were driven through the channels electrokinetically at 2.3 kV cm(-1), excited with a single 476 nm wavelength laser and detected with a confocal microscope. Fluorescence emission was collected simultaneously from green (500-590 nm) and red (610-680 nm) regions of the spectrum. Signal rejection was minimized by the narrow and symmetric emission spectra of the quantum dots. To demonstrate efficient multicolor detection and characterization of single molecule binding, Qdot 655 Streptavidin Conjugates were bound to Alexa Fluor 488 molecules and individually detected. Photon counting histogram analysis was used to quantify coincident detection and degree of binding. Fluorescence correlation spectroscopy was used to measure the mobility of bound and unbound species. The union of fluidic channels with submicrometer dimensions and quantum dots as fluorescent labels resulted in efficient and rapid multiplexed single molecule detection and analysis.

Fluorescent Dyes↗

Thin-film polymer light emitting diodes as integrated excitation sources for microscale capillary electrophoresis.

We report the use of a thin-film polymer light emitting diode as an integrated excitation source for microfabricated capillary electrophoresis. The polyfluorene-based diode has a peak emission wavelength of 488 nm, an active area of 40 microm x 1000 microm and a thickness of similar 2 mm. The simple layer-by-layer deposition procedures used to fabricate the polymer component allow facile integration with planar chip-based systems. To demonstrate the efficacy of the approach, the polyfluorene diode is used as an excitation source for the detection of fluorescent dyes separated on-chip by electrophoresis. Using a conventional confocal detection system the integrated pLED is successfully used to detect fluorescein and 5-carboxyfluorescein at concentrations as low as 10(-6) M with a mass detection limit of 50 femtomoles. The drive voltages required to generate sufficient emission from the polymer diode device are as low as 3.7 V.

Biosensing Techniques↗

Integrated on-chip derivatization and electrophoresis for the rapid analysis of biogenic amines.

We demonstrate the monolithic integration of a chemical reactor with a capillary electrophoresis device for the rapid and sensitive analysis of biogenic amines. Fluorescein isothiocyanate (FITC) is widely employed for the analysis of amino-group containing analytes. However, the slow reaction kinetics hinders the use of this dye for on-chip labeling applications. Other alternatives are available such as o-phthaldehyde (OPA), however, the inferior photophysical properties and the UV lambdamax present difficulties when using common excitation sources leading to a disparity in sensitivity. Consequently, we present for the first time the use of dichlorotriazine fluorescein (DTAF) as a superior in situ derivatizing agent for biogenic amines in microfluidic devices. The developed microdevice employs both hydrodynamic and electroosmotic flow, facilitating the creation of a polymeric microchip to perform both precolumn derivatization and electrophoretic analysis. The favorable photophysical properties of the DTAF and its fast reaction kinetics provide detection limits down to 1 nM and total analysis times (including on-chip mixing and reaction) of <60 s. The detection limits are two orders of magnitude lower than current limits obtained with both FITC and OPA. The optimized microdevice is also employed to probe biogenic amines in real samples.

Biogenic Amines↗

Single particle confocal fluorescence spectroscopy in microchannels: dependence of burst width and burst area distributions on particle size and flow rate.

This article presents a non-invasive, optical technique for measuring particulate flow within microfluidic channels. Confocal fluorescence detection is used to probe single fluorescently labeled microspheres (200-930 nm diameter) passing through a focused laser beam at a variety of flow rates (100 - 1000 nL/min). Simple statistical methods are subsequently used to investigate the resulting fluorescence bursts and generate single-particle burst width and burst area distributions. Analysis of such distributions demonstrates that the average burst width and burst area decrease as particle size increases. In addition, both burst width and burst area (for a given particle size) are observed to decrease as volumetric flow rate is increased. The dependence of such distributions on particle size is proposed as a potential route to sizing single particles and molecules in microfluidic systems.

Journal Article↗

Solution-phase electroluminescence.

We report emissive devices exhibiting electroluminescence in the solution phase. The principle operating mechanism for these devices--direct electronic carrier injection from the electrodes into the carrier bands of the dissolved polymer--resembles that of a conventional solid-state organic light-emitting diode and is distinct from the solvent-mediated electrochemical devices recently reported by Chang et al.

Journal Article↗