PubMed Health⌕ Search

Biomedical subjects

Joshua M Rosenow

Publications and source records attributed to Joshua M Rosenow.

13 recordsLinked to original sources

Associations between prescribed amphetamines and spontaneous cervical artery dissection: a matched case-control study.

AIMS: To assess whether prescribed amphetamines are associated with spontaneous cervical artery dissection (sCeAD), an important cause of stroke in young adults. METHODS: We conducted a retrospective matched case-control study within a large academic health system in Chicago, Illinois. Adults aged 18-85 years with incident sCeAD were matched 1:4 to controls without dissection on age, sex, and race/ethnicity. The primary exposure was documented amphetamine prescription. Conditional logistic regression was used to estimate adjusted odds ratios (ORs) controlling for relevant vascular and clinical covariates. Sensitivity analyses included strict matched-strata and inverse probability-weighted models. RESULTS: Among 11,463 individuals, including 2,293 cases and 9,170 controls, amphetamine exposure was associated with higher odds of sCeAD (adjusted OR 1.70, 95% CI 1.18-2.46). Results were unchanged in strictly matched strata (OR 1.70, 95% CI 1.18-2.46) and remained directionally consistent after inverse probability weighting (OR 1.40, 95% CI 1.09-1.79). High-dose amphetamine exposure (≥30 mg/day) had the strongest association (OR 1.96, 95% CI 1.18-3.26), whereas low-dose exposure was not statistically significant. CONCLUSION: Prescribed amphetamines were associated with modestly increased odds of sCeAD. While these findings are observational and hypothesis-generating, they may support a possible association in susceptible patients.

Humans↗

Application accuracy of an electromagnetic field-based image-guided navigation system.

OBJECTIVE: We tested the application accuracy of an electromagnetic field-based image guidance system to compare it to traditional optically tracked systems. METHODS: A plastic skull phantom was fitted with fiducial markers rigidly attached via self-drilling bone screws. Volumetric CT scan was obtained to simulate the clinical condition. A metal disc marked in 1-mm increments was placed at the expected target point. Following registration and alignment of a trajectory guide, radial and depth localization errors were measured after both freehand and stabilized approaches on both the right and left sides. Statistical analyses of the localization errors were performed. RESULTS: Total target localization error ranged from 0.71 to 3.51 mm with a mean +/- SEM of 2.13 +/- 0.11 mm. The radial error averaged 0.98 +/- 0.11 mm, depth error 1.74 +/- 0.13 mm. The freehand procedures produced a statistically greater radial, depth and total error than the fixed procedures. CONCLUSIONS: Accuracy of image-guided localization using an electromagnetic field guidance system is similar to that reported for optically guided systems.

Diagnostic Imaging↗

Failure modes of spinal cord stimulation hardware.

OBJECT: Epidural spinal cord stimulation (SCS) is effective at treating refractory pain. The failure modes of the implanted hardware, however, have not been well studied. A better understanding of this could aid in improving the current procedure or designing future devices. METHODS: The authors reviewed electronic charts and operative reports of 289 patients who had undergone SCS implantation between 1998 and 2002 at the Cleveland Clinic Foundation. Data were collected on demographics, type of hardware, date of implantation procedure, indication for treatment, time to failure, and failure mode. Data were then analyzed to identify significant differences. A total of 577 procedures were performed, 43.5% of which involved revision or removal of SCS hardware. The most common indication was complex regional pain syndrome 1, and this was followed by failed-back surgery syndrome. The median number of procedures per patient was two. Approximately 80% of all leads were the percutaneous type. The majority (62%) of leads were placed in the thoracic region, and 33.5% of all leads required revision. Poor pain relief coverage was the most common indication for revision. Surgically implanted leads broke twice as often as percutaneous leads. In 46% of the patients, hardware revision was required, and multiple revisions were necessary in 22.5%. Three-way ANOVA revealed significant differences in failure mode rates according to location (cervical compared with thoracic, p = 0.037) and failure modes (p = 0.019). Laminotomy leads tended to break and migrate sooner than percutaneous leads. Thoracic leads became infected sooner than cervical leads. CONCLUSIONS: The results of this analysis of SCS hardware failures may be used as a basis for refining surgical technique and designing the next generation of SCS hardware.

Adolescent↗

Frameless stereotaxy using bone fiducial markers for deep brain stimulation.

OBJECT: Functional neurosurgical interventions such as deep brain stimulation (DBS) are traditionally performed with the aid of a stereotactic frame. Although frameless techniques have been perceived as less accurate, data from a recent phantom study of a modified frameless approach demonstrated a laboratory accuracy exceeding that obtained using a common frame system. The present study was conducted to evaluate the accuracy of a frameless system in routine clinical use. METHODS: Deep brain stimulation leads were implanted in 38 patients by using a skull-mounted trajectory guide and an image-guided workstation. Registration was accomplished with bone fiducial markers. Final lead positions were measured on postoperative computerized tomography scans and compared with the planned lead positions. The accuracy of the Leksell frame within the clinical situation has been reported on in a recent study; these raw data served as a comparison data set. The difference between expected and actual lead locations in the x plane was 1.4 mm in the frame-based procedure and 1.6 mm in the frameless procedure. Similarly, the difference in the y plane was 1.6 mm in the frame-based system and 1.3 mm in the frameless one. The error was greatest in the z plane, that is, 1.7 mm in the frame-based method and 2 mm in the frameless system. Multivariate analysis of variance demonstrated no statistically significant difference in the accuracy of the two methods. CONCLUSIONS: The accuracy of the frame-based and frameless systems was not statistically significantly different (p = 0.22). Note, however, that frameless techniques offer advantages in patient comfort, separation of imaging from surgery, and decreased operating time.

Deep Brain Stimulation↗

Recovery of pain control by intensive reprogramming after loss of benefit from motor cortex stimulation for neuropathic pain.

INTRODUCTION: Motor cortex stimulation (MCS) may serve as an adjunct in managing neuropathic pain after other conservative and interventional methods have failed. However, the magnitude and duration of the benefit are highly variable, with a significant percentage of patients losing pain relief over time. We investigated whether intensive reprogramming could recapture the beneficial effects of MCS. METHODS: Six patients who had previously undergone MCS implantation for neuropathic pain but had lost benefit were brought back for 1-5 days of intensive reprogramming. Four patients were evaluated as inpatients while the others were seen as outpatients during multiple visits over several days. Several hours a day were spent with each patient. Patients completed visual analog scale (VAS) ratings at intervals throughout the reprogramming period to judge effectiveness of stimulation. Pre- and postadjustment VAS were compared using a paired t test. RESULTS: The patients' average age was 50 years (range 26-71). The diagnoses were trigeminal neuropathic pain (2 patients), complex regional pain syndrome I (2), phantom limb pain (1) and poststroke pain (1). The mean duration of pain was 6 years. The MCS benefit had initially lasted for a mean of 7.16 months (range 2-18 months). After reprogramming, 5 of 6 patients experienced improvement in pain. Average VAS scores decreased from 7.44 to 2.28 (p < 0.001) in those patients who responded to reprogramming. The average stimulation parameters in these patients were 5 V amplitude (range 1.7-10), 313 micros pulse width (range 240-390) and frequency of 84 Hz (range 55-130). Three patients experienced seizures during reprogramming. The mean seizure threshold was 8.9 V. No patient experienced seizures at their therapeutic settings. Pain control has been maintained after discharge. CONCLUSION: Intensive reprogramming can recapture the benefit of MCS in patients who have lost pain control. The use of broad dipoles using two contacts rather than one contact of the 1 x 4 electrode array improved the ability to recapture beneficial stimulation. There is a significant risk of seizures during aggressive reprogramming.

Adult↗

Deep brain stimulation for movement disorders.

Movement disorders remain the primary indication for the use of intracranial neurostimulation techniques. This review will discuss the history of this technology as well as the mechanisms of action, current clinical indications, and future prospects for the treatment of movement disorders.

Brain↗

The application accuracy of a skull-mounted trajectory guide system for image-guided functional neurosurgery.

OBJECTIVE: Frameless image guided systems have traditionally been perceived as being less accurate than stereotactic frames, limiting their adoption for trajectory-based procedures such as deep brain stimulator placement which require submillimetric accuracy. However, some studies have suggested that high degrees of accuracy are attainable with optical localization systems. We evaluated the application accuracy of a skull-mounted trajectory guide coupled to an optical image-guided surgery system in a laboratory setting. MATERIALS AND METHODS: A plastic skull phantom was fitted with five fiducial markers rigidly attached via self-drilling bone screws. Varying MRI and CT imaging protocols were obtained at 25 different centers. A metal disc marked in 1-mm increments was placed at the expected target point. Following registration and alignment of the trajectory guide, radial and depth localization errors were measured. A total of 560 measurements were obtained and detailed statistical analyses were performed. RESULTS: Mean localization error was 1.25 mm with a 95% confidence interval of 2.7 mm and a 99.9% confidence interval of 4.0 mm. These values were significantly lower than those published for the two most widely used frame systems (p<0.001). CONCLUSIONS: Accuracy of image-guided localization using a rigid trajectory guide can meet or exceed that achievable with a stereotactic frame.

Humans↗

Efficacy of multiple intraarterial papaverine infusions for improvement in cerebral circulation time in patients with recurrent cerebral vasospasm.

OBJECT: Cerebral vasospasm that is caused by aneurysmal subarachnoid hemorrhage and that is refractory to maximal medical management can be treated with selective intraarterial papaverine infusions. The effects of single papaverine treatments on cerebral circulation time are well known. The purpose of this study was to assess the efficacy of multiple, repeated papaverine infusions on the cerebral circulation time in patients with recurrent vasospasm. METHODS: A retrospective study was conducted in 17 patients who received multiple intraarterial papaverine infusions in 91 carotid artery (CA) territories for the treatment of cerebral vasospasm. Cerebral circulation times were measured from the first angiographic image, in which peak contrast was seen above the supraclinoid internal CA, to the peak filling of cortical veins. Glasgow Outcome Scale (GOS) scores assessed 12 months after discharge were reviewed. Cerebral circulation times in 16 CA territories were measured in a control group of 11 patients. Seventeen patients received a total of 91 papaverine treatments. Prolonged cerebral circulation times improved after 90 (99%) of 91 papaverine treatments. The prepapaverine mean cerebral circulation time was 6.54 seconds (range 3.35-27 seconds) and the immediate postpapaverine mean cerebral circulation time was 4.19 seconds (range 2.1-12.6 seconds), an overall mean decrease of 2.35 seconds (36%, p < 0.001). Recurrent vasospasm reflected by prolonged cerebral circulation times continued to improve with subsequent papaverine infusions. Repeated infusions were just as successful quantitatively as the primary treatment (mean change 2.06 seconds). The mean cerebral circulation time in the control group was 5.21 seconds (range 4-6.8 seconds). In five patients a dramatic reversal of low-attenuation changes was detected on computerized tomography scans. The mean GOS score at 12 months after discharge was 3.4. CONCLUSIONS: The preliminary results indicate that multiple intraarterial papaverine treatments consistently improve cerebral circulation times, even with repeated infusions in cases of recurrent vasospasm.

Adult↗

Anatomy and physiology of chronic pain.

Although much has been accomplished in the past several decades, treatment of chronic pain remains imperfect. This article presents the anatomy and physiology of the pain system along with the neurobiologic changes that occur in the establishment and maintenance of chronic pain states.

Brain↗

Precentral stimulation for chronic pain.

A decade of clinical experience has suggested that precentral stimulation is an option for patients with deafferentation as well as other chronic pain syndromes. Permanent complications are uncommon. More scientific evidence is warranted to understand the precise mechanisms for this treatment modality. A larger organized clinical trial is desired to establish the efficacy of precentral stimulation.

Brain↗

Simultaneous use of bilateral subthalamic nucleus stimulators and an implantable cardiac defibrillator. Case report.

Bilateral electrical stimulation of the subthalamic nucleus is being used with increasing frequency as a treatment for severe Parkinson disease (PD). Implantable cardiac defibrillators improve survival in certain high-risk patients with coronary artery disease and ventricular arrhythmias. Because of concern about possible interaction between these devices, deep brain stimulation (DBS) systems are routinely disconnected before defibrillators are implanted in patients with PD and arrhythmia. The authors report on a patient with bilateral subthalamic stimulators who underwent successful placement of an implantable defibrillator. Testing of the devices over a wide range of settings revealed no interaction. The patient subsequently underwent multiple episodes of cardioversion when the ventricular lead became dislodged. There was no evidence of adverse neurological effects, and interrogation of the DBS devices after cardioversion revealed no changes in stimulus parameters. The outcome in this case indicates that DBS systems may be safely retained in selected patients who require implantable cardiac defibrillators.

Aged↗

Hypophysopexy technique for radiosurgical treatment of cavernous sinus pituitary adenoma.

Stereotactic radiosurgery is being used with increased frequency in the treatment of residual or recurrent pituitary adenomas. The major risk associated with radiosurgical treatment of residual or recurrent pituitary tumor adjacent to normal functional pituitary gland is radiation of the pituitary, which frequently leads to the development of hypopituitarism. The authors describe a technique of pituitary transposition to reduce the radiation dose to the normal pituitary gland in cases of planned radiosurgical treatment of residual pituitary adenoma within the cavernous sinus. A sellar exploration for tumor resection is performed, the pituitary gland is transposed from the region of the cavernous sinus, and a fat and fascia graft is interposed between the normal pituitary gland and the residual tumor in the cavernous sinus. The residual tumor may then be treated with stereotactic radiosurgery. The increased distance between the normal pituitary gland and the residual tumor facilitates treatment of the tumor with radiosurgery and reduces the radiation to the normal pituitary gland. An illustrative case of a young female with recurrent acromegaly and a pituitary adenoma invading the cavernous sinus is described.

Acromegaly↗