SENSE or k-MAG to accelerate free breathing navigator-guided coronary MR angiography.

OBJECTIVE: The purpose of this study was to assess the relative merits of reducing the scanning time of navigator-guided (NAV) coronary MR angiography by including, both independently and in combination, two time-saving strategies: k-space weighted motion-adapted gating (k-MAG) and sensitivity encoding (SENSE, factor = 2). SUBJECTS AND METHODS: Coronary arteries of 21 healthy subjects were imaged with four NAV MR angiography sequences: conventional NAV sequence, NAV with the addition of SENSE, NAV with the addition of k-MAG, and NAV with a combination of SENSE and k-MAG. All imaging parameters including the magnetization preparation schemes, prescribed spatial resolution, and acquisition duration per R-R interval were identical for all techniques. The total scanning time, navigator efficiency, visible length of the coronary artery, and subjective image quality were used as metrics for evaluating the performance of the techniques. RESULTS: The results show that the addition of k-MAG to NAV coronary MR angiography (with or without SENSE) improved scan efficiency and decreased scanning time by an average of 17% without compromising the length of coronary artery visible or the image quality. The addition of SENSE to the NAV technique (with or without k-MAG) reduces the scanning time by an average of 50%. CONCLUSION: While the average image quality of coronary arteries was unaffected by the addition of k-MAG to navigator techniques, there was a slight reduction in image quality scores for the navigator sequence with SENSE. Identification of the proximal coronary arteries was not hampered by the addition of k-MAG, SENSE, or both to the NAV coronary MR angiography sequence.

Adult↗

Sensitivity-encoded coronary MRA at 3T.

Long scan times are still a main limitation in free-breathing navigator-gated 3D coronary MR angiography (MRA). Unlike other MRI applications, high-resolution coronary MRA has not been amenable to acceleration by parallel imaging techniques due to signal-to-noise ratio (SNR) concerns. In the present work, mitigating SNR limitations by the transition to higher static magnetic field strength is proposed, thus enabling scan time reduction by the parallel sensitivity encoding (SENSE) technique. The study reports the implementation and evaluation of free-breathing navigator-gated 3D coronary MRA with SENSE at 3T. Results from 11 healthy subjects indicate that the approach permits significant scan time reduction in MRA of the left and right coronary systems. Quantitative image analysis and visual grading suggest that two-fold scan acceleration can be accomplished at nearly preserved image quality. The additional experiments appear to demonstrate that parallel MRA equally permits enhancing volume coverage and spatial resolution while maintaining scan time.

Adult↗

Initial experiences with in vivo right coronary artery human MR vessel wall imaging at 3 tesla.

Due to their relatively small size and central location within the thorax, improvement in signal-to-noise (SNR) is of paramount importance for in vivo coronary vessel wall imaging. Thus, with higher field strengths, coronary vessel wall imaging is likely to benefit from the expected "near linear" proportional gain in SNR. In this study, we demonstrate the feasibility of in vivo human high field (3 T) coronary vessel wall imaging using a free-breathing black blood fast gradient echo technique with respiratory navigator gating and real-time motion correction. With the broader availability of more SNR efficient fast spin echo and spiral techniques, further improvements can be expected.

Adult↗

Preliminary report on in vivo coronary MRA at 3 Tesla in humans.

Current limitations of coronary magnetic resonance angiography (MRA) include a suboptimal signal-to-noise ratio (SNR), which limits spatial resolution and the ability to visualize distal and branch vessel coronary segments. Improved SNR is expected at higher field strengths, which may provide improved spatial resolution. However, a number of potential adverse effects on image quality have been reported at higher field strengths. The limited availability of high-field systems equipped with cardiac-specific hardware and software has previously precluded successful in vivo human high-field coronary MRA data acquisition. In the present study we investigated the feasibility of human coronary MRA at 3.0 T in vivo. The first results obtained in nine healthy adult subjects are presented.