PubMed Health⌕ Search

Biomedical subjects

Joy Dunmore-Buyze

Publications and source records attributed to Joy Dunmore-Buyze.

2 recordsLinked to original sources

Evaluation of an algorithm for semiautomated segmentation of thin tissue layers in high-frequency ultrasound images.

An algorithm consisting of speckle reduction by median filtering, contrast enhancement using top- and bottom-hat morphological filters, and segmentation with a discrete dynamic contour (DDC) model was implemented for nondestructive measurements of soft tissue layer thickness. Algorithm performance was evaluated by segmenting simulated images of three-layer phantoms and high-frequency (40 MHz) ultrasound images of porcine aortic valve cusps in vitro. The simulations demonstrated the necessity of the median and morphological filtering steps and enabled testing of user-specified parameters of the morphological filters and DDC model. In the experiments, six cusps were imaged in coronary perfusion solution (CPS) then in distilled water to test the algorithm's sensitivity to changes in the dimensions of thin tissue layers. Significant increases in the thickness of the fibrosa, spongiosa, and ventricularis layers, by 53.5% (p < 0.001), 88.5% (p < 0.001), and 35.1% (p = 0.033), respectively, were observed when the specimens were submerged in water. The intraobserver coefficient of variation of repeated thickness estimates ranged from 0.044 for the fibrosa in water to 0.164 for the spongiosa in CPS. Segmentation accuracy and variability depended on the thickness and contrast of the layers, but the modest variability provides confidence in the thickness measurements.

Algorithms↗

Three-dimensional visualization and thickness estimation of aortic valve cusps using high-frequency ultrasound.

High-frequency ultrasound techniques are introduced for three-dimensional imaging and thickness estimation of fresh heart valve cusps. Images of porcine aortic valve specimens were acquired within a 12 x 8 x 8 mm3 volume using a VisualSonics VS40 micro-imaging system operating at a 40 MHz centre frequency. Two image volumes were obtained from each of six left coronary cusps. One volume was acquired with the specimen submerged in distilled water and the second volume was acquired through either Hanks physiologic solution or coronary perfusion solution (CPS). The fibrosa, spongiosa and ventricularis were most readily distinguished when the specimen was imaged in distilled water. Colour thickness maps were computed from B-mode image data, and the mean and standard deviations of the thickness were determined for each cusp. In 11 of 12 trials, the image analysis algorithm yielded valid thickness estimates over greater than 98% of the region examined. Mean thickness estimates obtained with specimens submerged in Hanks solution or CPS ranged from 0.66 to 1.03 mm, and submersion in distilled water increased the mean thickness by 20-40%. This observation suggests that the cusps osmotically absorbed water. Information provided by high-frequency ultrasound is expected be valuable for characterizing the morphological properties of heart valves.

Animals↗