PubMed Health⌕ Search

Biomedical subjects

Joyce Low

Publications and source records attributed to Joyce Low.

10 recordsLinked to original sources

Identification of factor inhibitors by diagnostic haemostasis laboratories: a large multi-centre evaluation.

We have assessed the proficiency of diagnostic haemostasis facilities to correctly identify coagulation factor abnormalities and inhibitors. Forty-two laboratories participating in the external Quality Assurance Program (QAP) conducted by the RCPA agreed to participate and were each sent a set of eight samples (each 3 x 1 ml) for evaluation. They were asked to blind test these samples for the presence or absence of inhibitors, and where identified, to perform further analysis (including specific inhibitor analysis). In order to make the exercise more challenging, in addition to true factor inhibitors, samples were provided that reflected potential pre-analytical variables that might arise and complicate inhibitor detection or lead to false inhibitor identification. In brief, the sample set comprised a true high level factor (F) V inhibitor, a true moderate level FVIII inhibitor (but sample was defibrinogenated), a true lupus anticoagulant (LA), a normal (but slightly aged) plasma sample, a normal serum sample, a normal EDTA sample, an oral anticoagulant/vitamin K deficiency sample, and a gross heparin ( approximately 10 U/ml) contaminated sample. Sixty-three percent of participants correctly identified the true FV inhibitor as such, although the reported range varied greatly [10 to >250 Bethesda units (BU/ml)] and 46% correctly identified the true FVIII inhibitor, despite the complication of the sample presentation, although the reported range also varied (7 to 64 BU/ml). Some laboratories either failed to identify the inhibitor present, or misidentified the inhibitor type. The LA, the oral anticoagulant/vitamin K deficiency, the normal serum sample, and the normal (aged) sample were also correctly identified by most laboratories, as was the absence of specific factor inhibitors in these samples. However, a small subset of laboratories incorrectly identified the presence of specific factor inhibitors in some of these samples. The heparin sample was also correctly identified by most (68%) laboratories. In contrast, the normal EDTA sample was misidentified as a FV and/or FVIII inhibitor by most (68%) laboratories, and only one laboratory correctly identified this as an EDTA sample. Thus, we conclude that although laboratories are able, in most cases, to identify the presence of true factor inhibitors, there is a large variation in identified inhibitor levels and there are also some significant errors in identification (i.e. false negatives and misidentifications). In addition, there is a significant false positive error rate where some laboratories will identify the presence of specific factor inhibitors where no such inhibitor exists (i.e. false positives).

Blood Coagulation Factors↗

Multilaboratory testing of thrombophilia: current and past practice in Australasia as assessed through the Royal College of Pathologists of Australasia Quality Assurance Program for Hematology.

We have conducted a series of multilaboratory surveys during the last 6 years to evaluate testing proficiency in the detection of congenital and acquired thrombophilia. For lupus anticoagulant (LA) testing, participant laboratories used a panel of tests, including activated partial thromboplastin time (aPTT; 100% of laboratories), kaolin clotting time (26 to 70%), and Russell's viper venom time (RVVT; 75 to 100%). Coefficients of variation (CVs) for assays ranged from 5 to 40%. RVVT assays appeared to be most sensitive and specific for detection of LA (fewer false-negatives or -positives), although laboratories performed best when they used a panel of tests. For congenital thrombophilia, tests evaluated comprised protein C (PC), protein S (PS), antithrombin (AT), and activated protein C resistance (APCR). Most participant laboratories performed PC using chromogenic (approximately 75%), or clot based (approximately 15%) assays, with few (< 10%) performing antigenic assessments. PS was most often assessed (approximately 60%) by immunological or antigenic assays, usually of free PS, or by functional or clot-based assays (approximately 40%). AT is usually assessed by functional chromogenic assays (approximately 95%). APCR was assessed using aPTT (approximately 50%) or RVVT (approximately 50%) clot-based assays, with the aPTT APCR typically performed using factor V-deficient plasma predilution, but the RVVT APCR typically performed without. Laboratories using the RVVT APCR generally performed better in detection of factor V Leiden-associated APCR, with the aPTT method group yielding higher false-negative and/or false-positive findings (approximately 5% of occasions). Some clot-based PC and PS assays appeared to be influenced by APCR status, and yielded lower apparent PC and PS levels with positive APC resistance. The overall error rate for PC, PS, and AT was approximately 2 to 8% (i.e., false-normal interpretations for deficient plasma or false-abnormal interpretations for normal plasma). The CVs for these assays ranged from 5 to 40%, with highest CVs typically obtained with PS assays.

Activated Protein C Resistance↗

An international survey of current practice in the laboratory assessment of anticoagulant therapy with heparin.

AIMS: We conducted a survey of laboratory practice for assessment of heparin anticoagulant therapy by participants of the Royal College of Pathologists of Australasia Quality Assurance Program (RCPA QAP). METHODS: A questionnaire was sent to 646 laboratories enrolled in the Haematology component of the QAP, requesting details of tests used for monitoring heparin therapy. RESULTS: Seventy laboratories (10.8%) returned results that indicated that they performed laboratory monitoring of heparin therapy. Most laboratories (69/70 = 98.6%) use the activated partial thromboplastin time (APTT) to monitor unfractionated heparin, with eight (11.4%) also using the APTT for monitoring low molecular weight (LMW) heparin. Five (7.1%) laboratories use the thrombin time (TT) test to help monitor heparin therapy and 37 (52.9%) laboratories use an anti-Xa assay to monitor heparin (either LMW or unfractionated). Normal reference ranges (NRR) for APTT differed considerably between laboratories, even those using the same reagent. Therapeutic ranges (TR) also differed considerably between laboratories, for both APTT and the anti-Xa assay. Laboratory differences in NRR and TR using the same reagents could only be partly explained by the use of different instrumentation. CONCLUSIONS: There is a large variation in current laboratory practice relating to monitoring of heparin anticoagulant therapy. This finding is similar to that of a similar survey conducted by the RCPA QAP almost a decade ago. This study suggests that better standardisation is still required for laboratory monitoring of heparin therapy.

Anticoagulants↗

Increased procoagulant phospholipid activity in blood from patients with suspected acute coronary syndromes: a pilot study.

Increased platelet activation is well documented in patients with acute coronary syndromes and can be detected by various methods, including flow cytometry and enzyme-linked immunosorbent assay. However, such techniques require several steps and cannot provide quick results. Platelet activation ultimately results in procoagulant phospholipid exposure and we have previously described a simple activated factor X-activated clotting time (XACT) test that is insensitive to resting platelets but that is significantly shortened by activated platelets, microparticles and procoagulant phospholipids. Our aim was to determine whether the XACT test could be used to distinguish patients with chest pain due to cardiac ischaemia from those having chest pain due to non-cardiac causes. We thus carried out XACT tests on ethylenediamine tetraacetic acid whole blood and plasma samples obtained from 46 patients presenting to the emergency department with chest pain and from 30 controls. Sixteen cases (30%) were subsequently diagnosed as acute coronary syndromes. Blood samples from these patients displayed overall significantly shortened XACT results relative to both healthy controls (P<0.001) and chest pain not due to cardiac ischaemia (P<0.004). This discrimination was much better with whole blood samples than when platelet-poor plasmas were tested (P=0.153), suggesting that free microparticles were not the only factors responsible. Thus, the detection of increased procoagulant phospholipid activity in whole blood by shortened XACT results may be a simple and rapid diagnostic marker of some cardiac ischaemic events.

Acute Disease↗

A single-centre prospective study of clinical and haemostatic risk factors for venous thromboembolism following lower limb arthroplasty.

Previous studies report conflicting results concerning the potential significance of thrombophilic genotypes in postarthroplasty venous thromboembolism (VTE). This study assessed thrombophilic genotypes, haemostatic and clinical variables as independent risk factors for VTE postarthroplasty. A total number of 569 patients undergoing elective lower limb arthroplasty at a single centre were prospectively studied. All patients were interviewed and had blood samples collected preoperatively. Bilateral lower limb ultrasonography was performed at day 7 +/- 2 postoperatively in all patients (ventilation/perfusion lung scanning in symptomatic patients only). The incidence of inhospital postoperative VTE was 26%. In univariate analysis - increased age, knee arthroplasty, recent surgery, general anaesthesia, shorter operation time, non-receipt of blood transfusion and differences in surgical practice (including use of pneumatic calf compression, surgical drains and postoperative bandaging techniques) were significantly associated with VTE. Factor V Leiden, prothrombin G20210A and MTHFR C677T mutations were not significant risk factors for VTE, and of all haemostatic variables tested, only median activated partial thromboplastin time showed significant difference between VTE and non-VTE patients (34 s vs. 33 s). Multiple logistic regression analysis demonstrated that increased age, knee arthroplasty and individual surgeon's routine practices were the only significant independent risks for VTE; hence routine preoperative blood screening for a potential hypercoaguable state is not indicated in this surgical setting.

Adult↗

How useful is the monitoring of (low molecular weight) heparin therapy by anti-Xa assay? A laboratory perspective.

We have conducted a series of laboratory-based surveys to assess variability in assay results utilized to monitor heparin anticoagulant therapy. These surveys involved laboratories participating in the Haematology component of the Royal College of Pathologists of Australasia Quality Assurance Program (RCPA QAP). Thirty five of 646 laboratories that were sent a preliminary questionnaire indicated that they performed anti-Xa assays and these laboratories were sent a panel of four plasma samples. These plasma samples contained respectively: (i) no added heparin, (ii) low molecular weight heparin (LMWH), enoxaparin, added to a level of approximately .5 U/mL, (iii) unfractionated heparin added to a level of approximately .5 U/mL, and (iv) LMWH added to a level of approximately 1.0 U/mL. Tests to be performed were the activated partial thromboplastin time (APTT), the thrombin time (TT), fibrinogen, and anti-Xa. As expected, returned results for APTT and TT showed some elevation in heparinized samples while fibrinogen assays were not affected. Anti-Xa assays yielded the following results (median [range]): (i) .01 [0-.11], (ii) .43 [.33-.80], (iii) .23 [.10-.49], and (iv) .90 [.60-1.30]. Thus, although median values were close to those anticipated, there was a wide variation in returned results. In a repeat exercise a few months later laboratories were also asked about their therapeutic ranges (TRs) and provided with an additional vial of LMWH-spiked (1.0 U/mL) plasma labeled as 'heparin-standard' to be used as an assay calibrant. TRs varied substantially between laboratories, from low ranges of .2-.4 to high ranges of .8-1.2. Anti-Xa assay results were similar to those of the first survey: (median [range]): (a) repeat testing: (i) .02 [0-.28], (ii) .47 [.34-.80], (iii) .25 [.14-.58], (iv) .95 [.65-1.31]; (b) repeat testing using survey provided 'heparin-standard': (i) .02 [0-.24], (ii) .55 [.4-.83], (iii) .28 [.10-.63], (iv) 1.00 [.9-1.16]. Thus using the provided 'heparin-standard' yielded lower variability in results for LMWH. In conclusion, the high variability of anti-Xa assay results coupled with the widely variable TRs suggests that therapeutic heparin monitoring is poorly standardized, and this raises some concerns over the clinical value of such monitoring.

Drug Monitoring↗

Detection of procoagulant phospholipid interfering in tests for lupus anticoagulant.

Excess platelets shorten most clotting tests for lupus anticoagulant (LA). Often it is not clear if a shortened, normal or slightly prolonged result in a test masks a weak LA in combination with activated platelets, which express procoagulant phospholipid (PPL). Our aim was to investigate a new LA-insensitive factor Xa-activated clotting time (XACT) test for detecting PPL in plasma specimens submitted for LA testing. In most clotting tests for PPL, specimens are mixed with human platelet-free plasma (PFP) to correct for factor defects. Such tests are usually very sensitive to prolongation by LA, which act against PPL-human clotting factor complexes. We found that phospholipid-free plasma from pigs could be used instead of human platelet-free plasma as substrate plasma without reducing sensitivity of XACT to PPL. However, the pig plasma-based system was significantly less affected by most LA. Activated platelets were detectable despite the presence of most LA. Since some LA still had significant prolonging effect on the XACT despite the use of pig plasma we investigated this further. ELISAs for IgG and IgM anti-beta2GP1 and anti-prothrombin antibodies were carried out on 23 specimens. We did not find that LA in plasmas displaying anti-prothrombin antibodies had less prolonging effect on the test based on pig plasma than that using human platelet-free plasma. Similarly, there were no subtyping trends apparent among results from anti-beta2GPI-positive samples. Our results do not support the concept that anti-prothrombin-dependent LA might be more species specific than anti-beta2GPI-dependent LA.

Animals↗

Factor V inhibitors: rare or not so uncommon? A multi-laboratory investigation.

Acquired deficiencies of, or inhibitors to, factor V are considered rare events. We report a series of 14 acquired factor V deficiencies, 10 of which were confirmed to have inhibitors to factor V, as identified within Australia in the past 5 years following a multi-laboratory investigation. The initial index case seen by one laboratory was followed within 4 months by a separate similar case. This prompted local contact with colleagues (n = 20) working in other haemostasis referral laboratories to identify the current case series. In total, nearly one-half of all haemostasis referral laboratories contacted had seen a case within the past 5 years. Clinical features and the apparent associated risk of bleeding complications generally varied, as did laboratory findings and the likely causal event. There were three females and 11 males. Age ranged from 44 to 95 years (median, 81 years). The level of inhibitor ranged from undetectable to over 250 Bethesda units. The probable cause leading to development of the inhibitors ranged from exposure to bovine thrombin, exposure to antibiotics, surgery and malignancy. Of additional interest was the apparent association of anti-phospholipid antibodies in many of the cases. For example, in the two similar index cases, with factor V inhibitor titres > 200 Bethesda units, high levels of anti-cardiolipin antibodies (> 70 GPL units) were also detected. Although less clear because of inhibitor interference, many of the cases also showed evident co-associated lupus anticoagulant activity. In conclusion, we report a series of factor V inhibitors recently identified within our geographic region that would represent an annual incidence of around 0.29 cases per million Australians. Although considered a rare finding, there is a high likelihood that most haemostasis referral laboratories will see a case every five or so years.

Adult↗

A new activated factor X-based clotting method with improved specificity for procoagulant phospholipid.

An improved activated factor X-based clotting method was used to investigate activity of procoagulant phospholipid (PPL) in blood samples collected into various anticoagulants and in plasmas with a range of abnormalities. The dilute activated factor X-activated clotting time (XACT) was carried out on a mixture of specimen with phospholipid-free porcine plasma. PPL from the test sample is then rate-limiting, controlling the clotting time so that the XACT is shortened from a maximum of approximately 120 s with citrated platelet-free plasma to approximately 30 s with freeze-thawed platelet-rich plasma. XACT results were only shortened slightly by fresh normal platelet-rich plasma, but were shortened significantly by platelets that had been activated by freeze-thawing. This improved method for PPL was not prolonged by deficiencies of known clotting factors and therapeutic levels of heparin, and it was surprisingly resistant to most lupus anticoagulants. However, it was extremely sensitive to PPL, detecting down to 50 ng/ml synthetic phospholipid added to phospholipid-free plasma. Excellent correlation was achieved between XACT shortening and microparticle count assessed by annexin V-binding and flow cytometry in normal plasma spiked with platelet microparticles. In citrated blood specimens, XACT shortened with time in a temperature-dependent manner. XACT results on blood samples anticoagulated with ethylenediamine tetra-acetate were more stable, and these would be preferable for assessing PPL expression ex vivo. XACT was significantly shorter in whole blood samples than in normal platelet-rich or platelet-poor plasmas, suggesting that PPL was normally expressed more by cells or aggregates larger than platelets or microparticles.

Annexins↗