PubMed Health⌕ Search

Biomedical subjects

Jozef L Beckers

Publications and source records attributed to Jozef L Beckers.

10 recordsLinked to original sources

System zones in capillary zone electrophoresis: moving boundaries caused by freely migrating hydrogen ions.

We demonstrate that system zones (SZs) can be expected in background electrolytes (BGEs) with a low buffer capacity. The mobilities of this type of SZ (m(SZ)) could be determined by calculations both based on a mathematical model and by a simulation program. The values of m(SZ) are increasing for decreasing buffer capacities and lower concentrations of the BGEs. For completely unbuffered BGEs with a pH below 7, the m(SZ) reached values up to 350x10(-9) m(2)V(-1)s(-1). This value indicates that the existence of this type of SZ originates from migrating hydrogen ions. Although both the mathematical model and simulation program do not consider the influence of the pH of the sample solution, experiments have shown that the pH of the sample solution is also very important. The lower the pH of the sample solution, the larger the m(SZ) in a specific BGE for cationic SZs. Using completely unbuffered BGEs the hydrogen ions present in the original sample start to migrate freely through the capillary tube with the mobility of a single hydrogen ion and cause stepwise disturbances in the base line of the detector trace. It is remarkable that this type of SZ appears not to affect the electromigration dispersion (EMD) in a strong way and so far only dips could be obtained experimentally.

Electrolytes↗

System zones in capillary zone electrophoresis: moving boundaries caused by freely migrating hydroxide ions.

We present theoretical and experimental data indicating that anionic system zones (SZs), due to free migrating hydroxide anions, can be expected in background electrolytes (BGEs) with a low buffer capacity. In the system containing completely unbuffered BGEs the hydroxide ions derived from the sample start to migrate freely through the capillary tube with the mobility of single hydroxide ions and cause stepwise disturbances in the baseline of the detector trace. Remarkably, this type of SZs do not appear to contribute significantly to the electromigration dispersion (EMD) of the zones of the analytes.

Buffers↗

Experimental assessment of electromigration properties of background electrolytes in capillary zone electrophoresis.

Electromigration dispersion (EMD) properties of background electrolytes (BGEs) used in capillary zone electrophoresis (CZE) are of key importance for the success of an analysis. The knowledge of these properties may serve well for the prediction of the asymmetry of peaks of analytes, for the prediction of unsafe regions where a strong interference of system zones may be expected, and for the selection of optimum conditions where the analytes of interest may give sharp and practically symmetric peaks. Present theories enable one to calculate and predict EMD properties of many BGEs but there is also a lot of BGEs that are beyond the present theoretical models as far as their composition and equilibria involved are considered. This contribution brings a method for assessment of EMD properties of any BGE from easily accessible experimental data. The method proposed is illustrated by model examples both for cationic and anionic separations. Imidazole acetate, histamine acetate, and histidine acetate served as model BGEs for cationic separations; as the model BGE for anionic separations, Tris-borate and sodium-borate BGEs have been selected since these buffers are frequently used and borate is well-known for its complexing equilibria in aqueous solutions.

Acetates↗

Calibrationless quantitative analysis by indirect UV absorbance detection in capillary zone electrophoresis: the concept of the conversion factor.

A new, fast and efficient procedure is described for the simultaneous quantitative analysis of various non-UV absorbing species in a sample, by capillary zone electrophoresis with indirect UV absorbance detection. The procedure is based on the concept of the conversion factor (CF). The CF of an analyte is defined as the ratio of the measured temporal peak area and the product of its migration time and transfer ratio (TR). Thus defined, the CF is of general validity for all analytes separated and detected in a given background electrolyte (BGE), since it has the same value for the same amounts of various analytes. If a sample is enriched with a known concentration of a standard component and analyzed by CZE, the CF of this standard component can be calculated and then the concentrations of all other analytes can be determined, without the use of any calibration graph. The individual TRs can be determined a priori from tabulated ionic mobilities and pK values of the analytes and of the constituents of the BGE or, for strong analytes, by using experimental data from the electropherogram of the analysis itself. The practical procedure of the analysis includes enrichment of the sample with a known quantity of a suitable standard and a single CZE run of the resulting mixture. The injected volume does not need to be known and thus the procedure also eliminates the injection error. The proposed procedure has been verified experimentally and reproducible and accurate values were obtained by using four different CZE apparatus for the analyses of standard mixtures of cations in three different BGEs.

Calibration↗

Capillary zone electrophoresis in methanol: migration behavior and background electrolytes.

Nonaqueous (NA) solutions are often used as background electrolytes (BGEs) and NA solvents are added to aqueous BGEs as organic modifiers in capillary zone electrophoresis (CZE), in order to optimize the separations. This can be tricky, however, because the pH* and pK* concepts may be totally different in NA solvents, whereas often less knowledge is available concerning phenomena, such as system zones, applying NA solvents. In this paper, the concepts of pH* and pK* are considered for methanol as a solvent and pK* values are determined for several components in mixtures of water and methanol. With a mathematical model, adapted for calculations in methanol, parameters are calculated describing the fronting or tailing character of peaks and the question of peaks or dips, and the existence of system zones is discussed for pure methanol as a solvent. These aspects are experimentally verified, applying BGEs useful for the separation of cationic species in the indirect UV mode. It can be concluded that the mathematical model developed for aqueous BGEs is applicable to BGEs in methanol, too, and that the behavior of BGEs in methanol is comparable with that in water concerning the fronting or tailing character of peaks and the question of peaks and dips, although the mobilities and pK values can change significantly.

Electrolytes↗

The preparation of background electrolytes in capillary zone electrophoresis: golden rules and pitfalls.

In this article the methodology of the design of suitable background electrolytes (BGEs) in capillary zone electrophoresis (CZE) is described. The principal aspects of the role of a BGE in CZE are discussed with respect to an appropiate migration behavior of analytes, including the transport of the electric current, the buffering of pH, the Joule heat, the electro-endosmotic flow (EOF) and the principal migration and detection modes. The impact of the composition of the BGE upon migration and detection is discussed. It is shown that the total concentration of the BGE is a principal factor and the adjustment of migrating analyte zones according to the Kohlrausch regulating function (KRF) is the principal effect in most of the sample stacking techniques. The number of co-ions and their properties are of key importance for peak shapes of the analyte peaks and for the existence of system zones. The detection of UV-transparent analytes may advanteously be done in the indirect UV mode, by using UV-absorbing co-ions, however, both peaks and dips may be expected in the UV trace in case of multiple co-ionic BGEs. Properties of BGEs can be predicted applying mathematical models and it is shown that with SystCharts, predictions can be given concerning the existence of system zones, detection modes and the peak shapes of analytes for a given BGE. Practical examples of methodological considerations are given in the design of suitable BGEs for four principal combinations of migration and detection modes. The properties of the BGEs selected are exemplified with experimental results. Golden rules are summarized for the preparation of suitable BGEs in CZE.

Electrolytes↗

Ampholytes as background electrolytes in capillary zone electrophoresis: sense or nonsense? Histidine as a model ampholyte.

A lot of phenomena, occuring in capillary zone electrophoresis (CZE), are linked with the ionic concentration of the background electrolyte (BGE). If weak bases and acids are used as BGEs in CZE, at a pH where they are scarcely ionized, the ionic concentration of the BGE is very low and this brings a strong peak broadening, limited sample stacking and low sample load. Because the electromigration dispersion increases extremely, moreover, the existence of low-conductivity BGEs in CZE is a contradiction in terms. The behavior of ampholytes as BGE in CZE is examined, by means of histidine as a model ampholyte. For BGEs consisting of histidine, important parameters, including the ionic concentrations, buffer capacity, transfer ratio, and the indicator for electromigration dispersion E(1)m(1)/E(2)m(2), are calculated at various pH. Although the transfer ratio is fairly constant over the whole pH traject, the ionic concentration and buffer capacity decrease whereas the electromigration dispersion strongly increases near the pI of histidine. I.e., that ampholytes can be applied as BGEs in CZE, however, just not at pH near their pI value, except as the difference between the pK values of the basic and acidic group, the deltapK value, is very small. For ampholytes with a low deltapK value or at high concentrations, all the before-mentioned effects are less fatal, but in that case we can not speak of a real low-conductivity BGE. If ampholytes are used at pH near their pK values, the use of ampholytes as BGE is not advantageously compared with simple weak bases and acids. This has been confirmed by calculations and experiments.

Buffers↗

Theory of system zones in capillary zone electrophoresis.

In the last years, it has been shown that the formation and migration of system zones is an inherent feature of capillary zone electrophoresis (CZE) and that it depends predominantly on the composition of an actual background electrolyte (BGE). In most of the currently used BGEs, the SZs are invisible by the UV absorbance detection system, however, the comigration of SZs with the zones of analytes deteriorates the analytical performance of CZE and may be fatal for its utilization. Therefore, the theoretical predictions of the existence and migration of SZs is of key importance for the expediency of CZE. This is a review of the theoretical treatments of SZs which reveals the origin and the properties of SZs and shows how to cope with them. Also, a table of some typical BGEs is presented where the existence and mobilities of SZs are given.

Electrophoresis, Capillary↗

Multivalent weak electrolytes - risky background electrolytes for capillary zone electrophoresis.

Multivalent weak acids and bases are useful components of buffers in electrophoresis. The use of such buffers as background electrolytes (BGEs) in capillary zone electrophoresis (CZE) is, however, risky due to the existence of unsafe regions in the analytical window of the separation. This contribution discusses the problems and shows that multivalent weak species in BGEs bring about the same effects as mixtures of two independent co-ions, i.e., the presence of two centers of symmetry in the electropherograms and the existence of a migrating system zone with a mobility in between these two centers of symmetry. The system zone deteriorates the analytical separation and detection of the analytes in its neighborhood. Illustrative experimental examples for both cationic and anionic CZE are shown and related discussion is given. Finally, some basic rules are formulated to avoid the preparation of risky BGEs.

Acids↗

Multiple effect of surfactants used as additives in background electrolytes in capillary zone electrophoresis: cetyltrimethylammonium bromide as example of model surfactant.

Surfactants are frequently used in the preparation of background electrolytes (BGEs) in capillary zone elcetrophoresis (CZE) in order to affect and to optimize both the electroosmotic flow (EOF) and the separation process. Their effects are, however, always multiple, the resulting situation may be very complex and the separation process may even be destroyed. We use the surfactant cetyltrimethylammonium bromide (CTAB) as a model example and bring experimental results and related discussion which elucidate the multiple effect of surfactants in an integrated way. It is shown that even at concentration levels lower than 10(-4) M CTAB strongly reduces the cathodic EOF in bare fused-silica capillaries and converts it into anodic EOF. The magnitude and polarity of the EOF depends not only on the concentration of CTAB but also on the composition of BGEs used. The interactions of CTA cations with the bare capillary wall reduce sorption of cationic analytes and enables their analysis. CTA cations at levels below their critical micelles concentration (CMC) already interact with anionic analytes and reduce their mobilities. This association is strong with highly charged anions and by this, the reversal of the EOF, applying BGEs with highly charged anions is less effective. These interactions are competitive and also depend on the composition of the BGE used. At levels above its CMC, CTAB forms micelles and enables the application of the micellar electrokinetic capillary chromatography (MEKC) mode and the analysis of, e.g., neutral components. Simultaneously, it is shown that the presence of CTAB may increase the number of potentially formed system zones.

Cetrimonium↗