Ultrasonic characterization of human trabecular bone microstructure.

New quantitative ultrasound (QUS) techniques involving ultrasound backscattering have been introduced for the assessment of bone quality. QUS parameters are affected by the transducer characteristics, e.g. frequency range, wave and pulse length. Although frequency-dependent backscattering has been studied extensively, understanding of the ultrasound scattering phenomenon in trabecular bone is still limited. In the present study, the relationships between QUS parameters and the microstructure of human trabecular bone were investigated experimentally and by using numerical simulations. Speed of sound (SOS), normalized broadband ultrasound attenuation (nBUA), average attenuation, integrated reflection coefficient (IRC) and broadband ultrasound backscatter (BUB) were measured for 26 human trabecular bone cylinders. Subsequently, a high-resolution microCT system was used to determine the microstructural parameters. Moreover, based on the sample-specific microCT data, a numerical model for ultrasound propagation was developed for the simulation of experimental measurements. Experimentally, significant relationships between the QUS parameters and microstructural parameters were demonstrated. The relationships were dependent on the frequency, and the strongest association (r = 0.88) between SOS and structural parameters was observed at a centre frequency of 5 MHz. nBUA, average attenuation, IRC and BUB showed somewhat lower linear correlations with the structural properties at a centre frequency of 5 MHz, as compared to those determined at lower frequencies. Multiple regression analyses revealed that the variation of acoustic parameters could best be explained by parameters reflecting the amount of mineralized tissue. A principal component analysis demonstrated that the strongest determinants of BUB and IRC were related to the trabecular structure. However, other structural characteristics contributed significantly to the prediction of the acoustic parameters as well. The two-dimensional numerical model introduced in the present study demonstrated good agreement with the experimental measurements. However, further studies with the simulation model are warranted to systematically investigate the relation between the structural parameters and ultrasound scattering.

Absorptiometry, Photon↗

Bone loss dynamics result in trabecular alignment in aging and ovariectomized rats.

Because of the destructive nature of techniques used to measure bone morphometry, studies of architectural changes and bone loss have utilized cross-sectional study designs, with all its inherent limitations in nuances. Here, the results of a longitudinal study using in vivo micro-CT are presented elucidating the dynamics of bone loss and architectural adaptation in rat models of aging and postmenopausal bone loss. Using 3-D methodology, we observed the changes in bone architecture in the proximal tibia of normally aging and ovariectomized rats for 54 weeks. Spatial patterns in bone resorption were observed that were similar for both groups. Remaining trabeculae increased in thickness or were remodeled into new trabecular structures, especially in the ovariectomized animals. The combination of bone loss and bone formation resulted in alignment of trabeculae across the growth plate. Cortical modeling that was associated with growth continued after cessation of longitudinal growth in the ovariectomized animals, resulting in shape changes of the proximal tibia. The organized nature of the changes in bone architecture that occurred after ovariectomy and the high similarity with the changes observed in the normally aging animals, suggest that estrogen depletion resulted in an acceleration of a normal bone adaptation process. The observed aligning of trabeculae suggests regulation through mechanical loading.

Aging↗

Prediction of density and mechanical properties of human trabecular bone in vitro by using ultrasound transmission and backscattering measurements at 0.2-6.7 MHz frequency range.

The ultrasound (US) backscattering method has been introduced as an alternative for the through-transmission measurement of sound attenuation and speed in diagnosis of osteoporosis. Both attenuation and backscattering depend strongly on the US frequency. In this study, 20 human trabecular bone samples were measured in transmission and pulse-echo geometry in vitro. The aim of the study was to find the most sensitive frequency range for the quantitative ultrasound (QUS) analyses. Normalized broadband US attenuation (nBUA), speed of sound (SOS), broadband US backscatter (BUB) and integrated reflection coefficient (IRC) were determined for each sample. The samples were spatially scanned with five pairs of US transducers covering a frequency range of 0.2-6.7 MHz. Furthermore, mechanical properties and density of the same samples were determined. At all frequencies, SOS, BUB and IRC showed statistically significant linear correlations with the mechanical properties or density of human trabecular bone (0.51 < r < 0.82, 0.54 < r < 0.81 and 0.70 < r < 0.85, respectively). In contrast to SOS, IRC and BUB, nBUA showed statistically significant correlations with mechanical parameters or density at the centre frequency of 1 MHz only. Our results suggest that frequencies up to 5 MHz can be useful in QUS analyses for the prediction of bone mechanical properties and density. Since the use of higher frequencies provides better axial and spatial resolution, improved structural analyses may be possible. While extensive attenuation of high frequencies in trabecular bone limits the clinically feasible frequency range, selection of optimal frequency range for in vivo QUS application should be carefully considered.

Algorithms↗

An improved segmentation method for in vivo microCT imaging.

UNLABELLED: Image segmentation methods for microCT can influence the accuracy of bone morphometry calculations. A new automated segmentation method is introduced, and its performance is compared with standard segmentation methods. The new method can improve the results of in vivo microCT, where the need to keep radiation dose low limits scan quality. INTRODUCTION: An important topic for microCT analysis of bone samples is the segmentation of the original reconstructed grayscale data sets to separate bone from non-bone. Problems like noise, resolution limitations, and beam-hardening make this a nontrivial issue. Inappropriate segmentation methods will reduce the potential power of microCT and may introduce bias in the architectural measurements, in particular, when new in vivo microCT with its inherent limitations in scan quality is used. Here we introduce a new segmentation method using local thresholds and compare its performance to standard global segmentation methods. MATERIAL AND METHODS: The local threshold method was validated by comparing the result of the segmentation with histology. Furthermore, the effect of choosing this new method versus standard segmentation methods using global threshold values was investigated by studying the sensitivity of these methods to signal to noise ratio and resolution. RESULTS: Using the new method on high-quality scans yielded accurate results and virtually no differences between histology and the segmented data sets could be observed. When prior knowledge about the volume fraction of the bone was available the global threshold also resulted in appropriate results. Degrading the scan quality had only minor effects on the performance of the new segmentation method. Although global segmentation methods were not sensitive to noise, it was not possible to segment both lower mineralized thin trabeculae and the higher mineralized cortex correctly with the same threshold value. CONCLUSION: At high resolutions, both the new local and conventional global segmentation methods gave near exact representations of the bone structure. When scanned samples are not homogenous (e.g., thick cortices and thin trabeculae) and when resolution is relatively low, the local segmentation method outperforms global methods. It maximizes the potential of in vivo microCT by giving good structural representation without the need to use longer scanning times that would increase absorption of harmful X-ray radiation by the living tissue.

Algorithms↗