Inline ultrasonic rheometry by pulsed Doppler.

This will be a discussion of the non-invasive determination of the viscosity of a non-Newtonian fluid in laminar pipe flow over the range of shear rates present in the pipe. The procedure used requires knowledge of the flow profile in and the pressure drop along a long straight run of pipe. The profile is determined by using a pulsed ultrasonic Doppler velocimeter. This approach is ideal for making non-invasive, real-time measurements for monitoring and control. Rheograms of a shear thinning gel will be presented. The operating parameters and limitations of the Doppler-based instrument will be discussed. The most significant limitation is velocity gradient broadening of the Doppler spectra near the walls of the pipe. This limitation can be significant for strongly shear thinning fluids (depending also on the ratio of beam to pipe diameter and the transducer's insertion angle).

Journal Article↗

Measuring fluid and slurry density and solids concentration non-invasively.

Staff at Pacific Northwest National Laboratory have developed a highly sensitive, non-invasive, self-calibrating, on-line sensor to measure the density, speed of sound, and attenuation of ultrasound for a liquid or slurry flowing through a pipeline; the approach can also be applied for measurements made in vessels. The sensor transducers are mounted directly upon the stainless steel wall and the pipeline wall becomes part of the measurement system. Multiple reflections within the stainless steel wall are used to determine the acoustic impedance of the liquid, where the acoustic impedance is defined as the product of the density and the speed of sound. The probe becomes self-calibrating because variations in the pulser voltage do not affect the measurements. This feature leads to the stability of the measurements and the instrument requires much less time and effort to calibrate. Further, the calibration remains constant in time, because it does not depend upon the pulser voltage remaining at a given value. By basing the measurement upon multiple reflections, the sensitivity of the measurement is significantly increased. For slurries with wt% solids concentration of 1% or less, high sensitivity is gained by analyzing attenuation measurements obtained from multiple paths through the slurry. For slurries with higher concentrations of solids, sufficient sensitivity is obtained by analyzing data from a simple transmission. Data are presented that show probe performance for each of these cases: very dilute and highly concentrated kaolin clay slurries.

Journal Article↗

Ultrasonic sensor to measure the density of a liquid or slurry during pipeline transport.

This paper describes the design and testing of a computer-controlled sensor for the real-time measurement of the density of a liquid or slurry. It is to be deployed at the US Department of Energy's Hanford Site in Richland, WA, to monitor slurry properties during radioactive waste transfers. To demonstrate the sensor performance, tests were carried out using non-radioactive waste simulants and the results will be presented. The sensor is mounted flush with the pipeline wall in a nominal 5-cm (2-in.) pipe spool piece. The design pressure is 2.8 MPa (400 psi). The probe wedge in contact with the slurry was selected to operate up to pH 14, and the probe components were radiation tested at exposures of 1 x 10(6) R. The sensor is applicable for process control of all types of liquids or slurries in pipelines or in vessels.

Journal Article↗