PubMed Health⌕ Search

Biomedical subjects

Juergen Maiss

Publications and source records attributed to Juergen Maiss.

5 recordsLinked to original sources

Currently available simulators: ex vivo models.

The introduction of the ex vivo tissue endoscopy simulators represents a major advance in endoscopic training, particularly in therapeutic endoscopy. The simulators have been popular teaching tools from the start, and the data supporting their benefit are accruing, especially in hemostasis training. Simulators like the compact EASIE may prove most beneficial as training tools for interventional skills that require repetitive practice and a larger volume of procedures than may occur naturally during the course of standard endoscopy practice. More data are needed to confirm that hands-on simulator training improves outcomes in clinical endoscopic performance and to characterize better the influence of such simulator work on subsequent endoscopic practice. As ex vivo simulators become more available, it is likely that these models will enhance initial training and also allow practicing gastroenterologists to acquire new techniques, maintain their skills, and demonstrate proficiency for credentialing purposes.

Animals↗

Evaluation of sensitivity and inter- and intra-observer variability in the detection of intestinal metaplasia and dysplasia in Barrett's esophagus with enhanced magnification endoscopy.

OBJECTIVE: Magnification endoscopy with acetic acid or dye for diagnosis of Barrett's esophagus is presently undergoing clinical evaluation. Current studies report good accuracy in predicting specialized intestinal metaplasia. To date, however, there is no definitive information on the inter- and intra-observer variability of these methods applied to the diagnosis of normal and dysplastic Barrett's mucosa. MATERIAL AND METHODS: Sixty patients with endoscopically suspected Barrett's esophagus were investigated prospectively with the zoom endoscope after contrast enhancement of the mucosa with 1.5% acetic acid. Two hundred and twenty-three enlarged and histologically investigated areas of gastric, cardiac, normal and dysplastic Barrett's mucosa were photodocumented and in randomized sequence presented to 4 endoscopists in a blinded manner (2 with and 2 without experience of zoom endoscopy for evaluation). The reference for the first evaluation (A1) was standard endoscopic photographs of the respective, histologically confirmed mucosal entity. In a second evaluation (A2), the pictures were again interpreted by the same blinded investigators, but this time a modified pit-pattern classification as proposed by Sharma et al. was employed as the evaluation reference. RESULTS: The diagnostic sensitivity for specialized intestinal metaplasia and dysplasia in Barrett's esophagus calculated for the A1 evaluation ranged -- investigator dependently -- from 54.9% to 80.7% and for A2 from 42.2% to 81.5%. The inter- and intra-observer variability for the evaluation procedure A1 and A2 was high (all kappa values <0.4). In particular, the inexperienced investigators demonstrated high intra-observer variability and low sensitivity in comparison with the experienced investigators. CONCLUSIONS: The diagnosis of Barrett's mucosa using enhanced magnification endoscopy after acetic acid instillation is associated with a high level of interobserver variability. One reason is a frequent mismatch between cardiac mucosa and non-dysplastic Barrett's mucosa.

Adult↗

The complementary Erlangen active simulator for interventional endoscopy training is superior to solely clinical education in endoscopic hemostasis--the French training project: a prospective trial.

BACKGROUND: The Erlangen Active Simulator for Interventional Endoscopy (EASIE) using ex-vivo porcine organs was introduced in 1997. The present study should analyze whether repeated EASIE simulator training in endoscopic hemostasis led to superior performance compared with a traditionally educated group. The results were compared with a similar project in New York. METHODS: Thirty-five French GI fellows were enrolled. Baseline skills evaluation was performed in four disciplines (manual skills, injection/coagulation, clip application and variceal ligation) using the compactEASIE-simulator equipped with an upper gastrointestinal organ package for bleeding simulation. The same, translated evaluation forms (from the prior New York project) were used. Subsequently, fellows were randomized into group A (n=17, only clinical education) and group B (n=18, additional three simulator trainings). Group B was trained the next day and after 4 and 7 months by experts of the French Society of Gastrointestinal Endoscopy. Both groups performed routine and emergency endoscopies at their home hospitals during the study period. Both groups were re-evaluated blindly after 9 months. RESULTS: The learning curve for group B showed a significant improvement in all disciplines (P<0.004) whereas group A improved significantly in only two of four disciplines at blinded final evaluation (manual skills P=0.02, injection/coagulation P=0.013). The direct comparison of groups B and A at blinded final evaluation showed significantly superior ratings for group B in all disciplines (P<0.006) and significantly shorter performance times in two disciplines (P=0.016 each). The comparison with the similar 'New York project' revealed that preexisting differences in skills were adjusted by the training. CONCLUSION: Complementary trainings (three workshops in 7 months) in endoscopic hemostasis using the compactEASIE improved skills compared with a solely clinical education. The results of the 'New York project' were confirmed and benefits were independent from the medical educational system.

Animals↗

Training with the compactEASIE biologic endoscopy simulator significantly improves hemostatic technical skill of gastroenterology fellows: a randomized controlled comparison with clinical endoscopy training alone.

BACKGROUND: The Erlangen Active Simulator for Interventional Endoscopy (EASIE) was introduced in 1997 for interventional endoscopy training. compactEASIE developed in 1998 is a modified, light-weight version of the original model. Objective evidence of the benefits of training with these models is limited. A randomized controlled study, therefore, was conducted to compare the effects of intensive 7-month, hands-on training in hemostatic techniques by using the compactEASIE model (in addition to clinical endoscopic training) vs. pure clinical training in endoscopic hemostatic methods. METHODS: Thirty-seven fellows in gastroenterology in New York City area training programs were enrolled. Baseline skills were assessed on the simulator for the following techniques: manual skills, injection and electrocoagulation, hemoclip application, and variceal ligation. Twenty-eight fellows were then randomized into two comparable groups. Those randomized to Group A received purely clinical training in endoscopic hemostatic techniques at their hospitals. Those in Group B, in addition, were trained by experienced tutors in 3 full-day hemostasis workshops over 7 months. Both groups underwent a final evaluation on the compactEASIE simulator conducted by their tutors and additional evaluators who were blinded to the method of training. Initial and final evaluation scores were compared for each group and between groups. Outcomes of actual clinical hemostatic procedures performed during the study period also were analyzed. RESULTS: Ten of 14 fellows randomized to Group A (standard training) and 13 of 14 in Group B (intensive training) returned for the final evaluation. For Group B, scores for all techniques were significantly improved. In Group A, a significant improvement was noted for variceal ligation alone. CONCLUSIONS: compactEASIE simulator training (3 sessions over 7 months), together with clinical endoscopic training resulted in objective improvement in the performance by fellows of all 4 endoscopic hemostatic techniques, whereas significant improvement was noted for variceal ligation alone for fellows who had standard clinical training. In clinical practice, fellows who had intensive simulator/clinical training had a significantly higher success rate and a nonsignificant reduction in the frequency of occurrence of complications.

Animals↗