PubMed Health⌕ Search

Biomedical subjects

Juergen Zanow

Publications and source records attributed to Juergen Zanow.

3 recordsLinked to original sources

Flow reduction in high-flow arteriovenous access using intraoperative flow monitoring.

PURPOSE: This study used intraoperative monitoring of the access flow to evaluate the results of flow reduction in the management of high-flow arteriovenous access-related symptoms of distal ischemia and cardiac insufficiency. METHODS: A retrospective study was conducted of 95 patients (78 with ischemia, 17 with cardiac failure) who underwent flow reduction between 1999 and 2005. A preoperatively measured access flow-volume rate > 800 mL/min for autogenous accesses (n = 77) and > 1200 mL/min for prosthetic accesses (n = 18) was the selection criterion for the use of a flow reduction procedure. Flow reduction was achieved using a spindle-like narrowing suture near the anastomosis and final placement of a polytetrafluoroethylene strip while a flow meter was used for intraoperatively measuring the access flow. The desired postoperative flow was 400 mL/min for autogenous and 600 mL/min for prosthetic accesses. RESULTS: The mean preoperative access flow was 1469 +/- 633 mL/min in patients with ischemia and 2084 +/- 463 mL/min in patients with cardiac failure, without significant differences between access types. The flow was reduced to 499 +/- 175 mL/min for autogenous accesses and to 676 +/- 47 mL/min for prosthetic accesses. The mean follow-up was 25 months (range, 1 to 73 months). Complete long-term relief of symptoms was observed in 86% of patients with ischemia and in 96% of patients with cardiac failure. Reconstruction significantly increased the digital-brachial index (0.41 +/- 0.12 vs 0.74 +/- 0.11; P < .05) and mean distal arterial pressure (47 +/- 17 mm Hg vs 79 +/- 21 mm Hg; P < .05) in patients with ischemia. Primary patency rates were significantly better for reconstructed autogenous accesses compared with rates of prosthetic accesses (91% +/- 4% vs 58% +/- 12% at 12 months; 81% +/- 6% vs 41% +/- 14% at 36 months; P < .001). The low patency of reconstructed prosthetic accesses is due to the high thrombosis risk of accesses that have a flow < 700 mL/min. CONCLUSIONS: Flow reduction using intraoperative access flow monitoring is an effective and durable technique allowing for the correction of distal ischemia and cardiac insufficiency in patients with a high-flow autogenous access. The desired postoperative access flow of 400 mL/min is not associated with an increased risk of thrombosis. Flow reduction of prosthetic access is as effective; however, a higher access flow than the desired 600 mL/min seems to be necessary to achieve an acceptable patency in prosthetic accesses.

Arteries↗

Arterioarterial prosthetic loop: a new approach for hemodialysis access.

OBJECTIVES: In this report we present a novel procedure that uses an arterioarterial prosthetic loop (AAPL) with the proximal axillary or the femoral artery as a vascular access for hemodialysis in patients who have inadequate vascular conditions for creating an arteriovenous fistula or graft. METHODS: Between April 1996 and September 2004, 34 patients received 36 AAPLs as vascular access, either as an axillary chest loop (n = 31) or as a femoral loop (n = 5). In this procedure the artery is ligated between the anastomoses to direct flow through the AAPL. Data from all patients undergoing the procedure were prospectively collected. RESULTS: The indication for an AAPL was the unsuitability of large deep veins in 64%, steal syndrome in 11%, the combination of only a suitable femoral vein and severe peripheral arterial disease in 22%, and congestive heart failure in 3%. All AAPLs were cannulated 18 +/- 4 days postoperatively. Mean follow-up was 31 months (range, 1 to 83). Primary patency was 73% and secondary patency was 96% at 1 year; these rates at 3 years were 54% and 87%, respectively. The rate of all interventions for the maintenance of AAPL function was 0.47 procedures per patient year. Four grafts were abandoned. More than 11,000 hemodialyses with proven efficiency were performed. CONCLUSIONS: The AAPL is an unusual but useful and easy-to-perform alternative procedure to create vascular access for hemodialysis. It can provide survival for strictly selected patients in whom conventional vascular access is not possible. The axillary chest AAPL is preferred.

Arteriovenous Shunt, Surgical↗

Computational fluid dynamics and vascular access.

Anastomotic intimal hyperplasia caused by unphysiological hemodynamics is generally accepted as a reason for dialysis access graft occlusion. Optimizing the venous anastomosis can improve the patency rate of arteriovenous grafts. The purpose of this study was to examine, evaluate, and characterize the local hemodynamics and, in particular, the wall shear stresses in conventional venous end-to-side anastomosis and in patch form anastomosis (Venaflo) by three-dimensional computational fluid dynamics (CFD). We investigated the conventional form of end-to-side anastomosis and a new patch form by numerical simulation of blood flow. The numerical simulation was done with a finite volume-based algorithm. The anastomotic forms were constructed with usual size and fixed walls. Subdividing the flow domain into multiple control volumes solved the fundamental equations. The boundary conditions were identical for both forms. The velocity profile of the patch form is better than that for the conventional form. The region of high static pressure caused by flow stagnation is reduced on the vein floor. The anastomotic wall shear stress is decreased. The results of this study strongly support patch form use to reduce the incidence of intimal hyperplasia and venous anastomotic stenoses.

Algorithms↗