PubMed Health⌕ Search

Biomedical subjects

Juhani T Soini

Publications and source records attributed to Juhani T Soini.

8 recordsLinked to original sources

Theoretical assessments of errors in rapid immunoassays-how critical is the exact timing and reagent concentrations?

The reliability of rapid immunoassay is a concern due to an incomplete incubation to a non-equilibrium state and is susceptible to different error factors causing variance. The most critical point in the process should be found in order to improve the accuracy, and reproducibility of immunoassays, and enhance the system robustness. In this paper, the behavior of rapid assays is predicted by simulations using mechanistic assay model, based on antibody-analyte binding reaction kinetics. This antibody-analyte binding reaction kinetics model was constructed for a generic three-component (immunometric) assay and the parameters were chosen to be those of a known surface binding assay. The effects of the exact incubation timing and the initial reagent concentrations were studied focusing on the early phase of incubation, the non-equilibrium state. The magnitudes of errors in the input parameters were estimated using knowledge from practical immunoassays. According to simulations, inaccurate incubation timing adds error in the results at very short incubation times, especially in low analyte concentrations. The inaccurate reagent concentrations increase variance at short incubation times, as well. The error decreases rapidly after the first few minutes of incubation.

Antigen-Antibody Complex↗

Robust estimation of bioaffinity assay fluorescence signals.

In this paper, the challenging problem of robust mean-signal estimation of a single-step microparticle bioaffinity assay is investigated. For this purpose, a density estimation-based robust algorithm (DER) was developed. The DER algorithm was comparatively evaluated with four other parameter estimation methods (mean value, median filtering, least square estimation, Welsch robust m-estimator). Two important questions were raised and investigated: 1) Which of the five methods can robustly estimate the mean bioaffinity signal? and 2) How many microparticles need to be measured in order to obtain an accurate estimate of the mean signal value? To answer the questions, bootstrap and coefficient of variation (CV) analyses were performed. In the CV analysis, the DER algorithm gave the best results: The CV ranged from 0.8% to 4.9% when the number of microparticles used for the mean signal estimation varied from 800 to 30. In the bootstrap analysis of the standard error, the DER algorithm had the smallest variance. As a conclusion, it can be underlined that: 1) of all methods tested, the DER algorithm gave the most consistent and reproducible results according to the bootstrap and CV analysis; 2) using the DER algorithm accurate estimates could be calculated based on 80-100 particles, corresponding to a typical assay measurement time of 1 min; and 3) the investigated bioaffinity signals contained a large number of outliers (observations that severely deviate from the majority of data) and therefore robust techniques were necessary for the mean signal estimation tasks.

Algorithms↗

Two-photon excitation in fluorescence polarization receptor-ligand binding assay.

Fluorescence polarization is one of the most commonly used homogeneous assay principles in drug discovery for screening of potential lead compounds. In this article, the fluorescence polarization technique is combined with 2-photon excitation of fluorescence. Theoretically, the use of 2-photon excitation of fluorescence increases the volumetric sensitivity and polarization contrast of fluorescence polarization assays. The work in this report demonstrates these predictions for an estrogen receptor ligand binding assay.

Fluorescence Polarization↗

New separation-free assay technique for SNPs using two-photon excitation fluorometry.

A new separation-free method for detection of single nucleotide polymorphisms (SNPs) is described. The method is based on the single base extension principle, fluorescently labeled dideoxy nucleotides and two-photon fluorescence excitation technology, known as ArcDia trade mark TPX technology. In this assay technique, template-directed single base extension is carried out for primers which have been immobilized on polymer microparticles. Depending on the sequence of the template DNA, the primers are extended either with a labeled or with a non-labeled nucleotide. The genotype of the sample is determined on the basis of two-photon excited fluorescence of individual microparticles. The effect of various assay condition parameters on the performance of the assay method is studied. The performance of the new assay method is demonstrated by genotyping the SNPs of human individuals using double-stranded PCR amplicons as samples. The results show that the new SNP assay method provides sensitivity and reliability comparable to the state-of-the-art SNaPshot trade mark assay method. Applicability of the new method in routine laboratory use is discussed with respect to alternative assay techniques.

DNA Primers↗

Fluorescent nanoparticles as labels for immunometric assay of C-reactive protein using two-photon excitation assay technology.

We describe the use of fluorophore-doped nanoparticles as reporters in a recently developed ArcDia TPX bioaffinity assay technique. The ArcDia TPX technique is based on the use of polymer microspheres as solid-phase reaction carrier, fluorescent bioaffinity reagents, and detection of two-photon excited fluorescence. This new assay technique enables multiplexed, separation-free bioaffinity assays from microvolumes with high sensitivity. As a model analyte we chose C-reactive protein (CRP). The assay of CRP was optimized for assessment of CRP baseline levels using a nanoparticulate fluorescent reporter, 75 nm in diameter, and the assay performance was compared to that of CRP assay based on a molecular reporter of the same fluorophore core. The results show that using fluorescent nanoparticles as the reporter provides two orders of magnitude better sensitivity (87 fM) than using the molecular label, while no difference between precision profiles of the different assay types was found. The new assay method was applied for assessment of baseline levels of CRP in sera of apparently healthy individuals.

Antibodies, Monoclonal↗

Detection methods of microsphere based single-step bioaffinity and in vitro diagnostics assays.

Microspheres provide a solid phase substrate for bioaffinity binding similar to the walls of traditional test tubes and the wells of microtiter plates. The coated microsphere concentrates analyte molecules in the reaction volume on its surface. When the bioaffinity binding reaction has reached an equilibrium, the local concentration of the analyte in close proximity of the microsphere is orders of magnitude higher than the concentration of the analyte in the total reaction volume. The preparation and quality control of microspheres coated with bioactive material is less costly and labour intensive when compared to test tube or microwell plate coating procedures. In addition, the cost for logistics and transportation of microsphere reagents is lower than that of coated tubes or plates. Moreover, microspheres can be easily used in miniaturised assay formats and several different detection schemes can be employed in the measurement of microsphere-based assays. Several different types of microspheres are commercially available. The microspheres can be manufactured in different sizes from many materials, such as polystyrene, acrylate, and glass. The surface of the microspheres can be activated to enable covalent binding of biomolecules. Further, the microspheres may contain internal fluorochrome or magnetic material, for identification or separation purposes. In this paper we review different assay formats for single-step measurement of bioaffinity assays employing microspheres. The term single-step is used to describe assays where all reagents and the sample are mixed, incubated and measured without separate washing steps.

Antibodies↗

Performance evaluation of the phosphorescent porphyrin label: solid-phase immunoassay of alpha-fetoprotein.

Phosphorescent conjugates of antibodies, neutravidin, and biotin (pentylamine derivative) were synthesized using previously described monofunctional labeling reagent of platinum(II) coproporphyrin-I with isothiocyanate reactive group (PtCP-NCS). These conjugates, which can be considered as standard reagents for a range of bioanalytical applications, were evaluated in solid-phase immunoassay schemes with the clinical analyte a-fetoprotein (AFP). A custom-designed time-resolved phosphorescence plate reader based on a compact and low-cost 532-nm laser and optimized for measurement of porphyrin labels was used. Using optimized tracers, instrumentation and assay protocols, subpicomolar detection limits were obtained both for PtCP label in solution and for AFP in solid-phase immunoassay. This sensitivity is comparable with standard time-resolved fluorescence immunoassays with lanthanide labels. The performance of metalloporphyrin labels, instrumentation, and solid-phase immunoassays as an alternative to the established detection platforms is discussed.

Biotin↗

Two-photon excitation fluorometric measurement of homogeneous microparticle immunoassay for C-reactive protein.

Recent developments in infrared laser technology have enabled the design of a compact instrumentation for two-photon excitation microparticle fluorometry (TPX). The microparticles can be used in immunoassays as the antibody-coated solid phase to capture an antigen and then detect it with a fluorescently labeled tracer antibody. Unlike most other methods, TPX technology allows low-volume, homogeneous immunoassays with real-time measurements of assay particles in the presence of a moderate excess of fluorescent tracer. In this study, the TPX assay system was used for the reagent characterization and the measurement of C-reactive protein (CRP) in diluted plasma samples, targeting the assay range useful in infectious disease diagnosis. The pentameric structure of the CRP permitted the optimization of an assay with the lowest detectable concentration of 1 microg/L (7.5 pM) by using a single monoclonal antibody both for capture and as the tracer. With a 1:200 predilution of samples, the measurement range of the assay was 1-150 mg/L, but an additional 1:10 dilution was required for higher concentrations. The TPX method showed a good correlation with the reference result obtained in a routine hospital laboratory, demonstrating the feasibility of the technology for immunodiagnostic applications.

Antibodies, Monoclonal↗