Publications and source records attributed to Jules M van den Bosch.

3 recordsLinked to original sources

Diffusing capacity for nitric oxide: reference values and dependence on alveolar volume.

Nitric oxide (NO) has a much stronger affinity for hemoglobin than carbon monoxide (CO); therefore, the DL(NO) (diffusing capacity for NO) is less influenced by changes in capillary blood volume than the DL(CO) (diffusing capacity for CO), and represents the true membrane diffusing capacity. We measured the combined single breath DL(NO)/DL(CO) in 124 healthy subjects, and generated reference equations for the DL(NO) and K(NO). In a subset of 21 subjects the measurements were performed on different inspiratory levels. The reference equation for DL(NO) in females is 53.47*H(height)0.077*A(age)-48.28(RSD5.22) and for males 59.84*H-0.25*A-44.20(RSD6.39). Reference equations for K(NO) in females is -2.03*H-0.025*A+11.52(RSD0.48) and for males -0.15*H-0.045*A+9.47(RSD0.65). The K(CO) (DL(CO)/V(A)) increases when V(A) (alveolar volume) decreases, probably due to an increase of blood volume per unit lung volume. The DL(NO) was much stronger related to the V(A), the K(NO) was almost independent of V(A). Because of the relative independence of the K(NO) on V(A), the K(NO) appears to be a much better index for the diffusion capacity per unit lung volume (transfer coefficient) than the K(CO).

Adult↗

The mucin-1 568 adenosine to guanine polymorphism influences serum Krebs von den Lungen-6 levels.

Krebs von den Lungen (KL)-6 offers a new perspective as a disease marker in pulmonary diseases. The aim of this study was to analyze whether serum KL-6 levels are dependent on the functional adenosine to guanine mucin-1 (MUC1) gene polymorphism at nucleotide position 568 in a well-characterized white population. Polymorphisms were determined in 327 healthy, white individuals and 74 patients with sarcoidosis, using a PCR-sequence-specific primer assay. The serum KL-6 levels were measured by ELISA. Significant differences between serum KL-6 levels of healthy subjects who were grouped according to MUC1 568 genotype were observed (P<0.0001) (mean+/-SEM): AA (195.2+/-9.9 U/ml; 95% confidence interval [CI], 175.7-214.8), AG (246.0+/-8.6 U/ml; 95% CI, 229.0-263.1), and GG (302.6+/-11.8 U/ml; 95%CI, 279.3-326.0). In the patients with sarcoidosis, the results were (mean+/-SD): AA (550.1+/-411.7; 95% CI, 380.2-720.1), AG (716.3+/-452.4; 95% CI, 547.4-885.2), GG (1,151.0+/-1122; 95% CI, 610.1-1692.0); P=0.02. Comparison of the KL-6 levels in which the 568 genotype was ignored rendered 6 out of 74 (7.5%) misclassifications of "elevated" versus "normal" KL-6 levels or vice versa. In conclusion, the MUC1 568 A to G polymorphism may be of interest for diagnostic purposes because our study delivered in vivo evidence that it contributes to interindividual variations in KL-6 levels.

Adenosine↗

Validation of a new method to measure hydrogen peroxide in exhaled breath condensate.

Inflammatory processes in the lung can or will elicit oxidative stress. The degree of oxidative stress can be determined by measuring hydrogen peroxide (H(2)O(2)) concentration in exhaled breath condensate (EBC) but the methods to measure H(2)O(2) are all rather time consuming and only reliable and/or accurate in the hand of skilled technicians in a dedicated laboratory. We tested a new commercial device (Ecocheck), developed to offer a less time-consuming method to measure H(2)O(2). We validated this new method according the NCCLS EP10-A2 protocol. The validation shows that the imprecision in the low range is high (28.4%) and declines with higher concentrations of H(2)O(2) (up to 6.6%). The Ecocheck is "an easy to use" measuring device for routine measurements getting quick results without the need for skilled technicians to determine H(2)O(2) concentrations.

Adult↗