PubMed Health⌕ Search

Biomedical subjects

Juliana V Rossi

Publications and source records attributed to Juliana V Rossi.

6 recordsLinked to original sources

Effect of oxygenated intraocular irrigation solutions on the electroretinogram after vitrectomy.

PURPOSE: To investigate the effect of oxygenated intraocular irrigating solutions on electroretinograms (ERGs) for postvitrectomy rabbits. METHODS: Eight groups of five rabbits each underwent pars plana vitrectomy on the right eye; the left eye of each rabbit served as control. The intraocular irrigating solutions were balanced salt solution (BSS), BSS-plus, BSS + oxygen (BSS + O2), BSS-plus + O2, and combinations of each with the addition of endoillumination (L). All animals were evaluated by single-flash scotopic electroretinography on the operated and nonoperated eyes before surgery and at 1 hour, 1 day, 1 week, and 1 month after surgery by an unmasked observer. The main outcome measures were dark-adapted b-wave amplitudes of operated eye/nonoperated eye ratios. The results for the different groups were compared by analysis of variance. RESULTS: Mean dark-adapted b-wave amplitudes of operated eye/nonoperated eye ratios +/- SD for BSS-plus and BSS-plus + O2 before surgery and 1 hour, 1 day, 1 week, and 1 month after surgery were 1.01 +/- 0.09, 0.50 +/- 0.11, 0.95 +/- 0.11, 0.97 +/- 0.11, and 0.99 +/- 0.08 and 0.98 +/- 0.08, 0.59 +/- 0.10, 0.92 +/- 0.06, 0.97 +/- 0.08, and 0.97 +/- 0.10, respectively. At both 1 hour and 1 day after surgery, rabbits treated with BSS-plus + O2 had an earlier b-wave return to baseline findings, but the differences were not statistically significant (P > 0.05). Mean dark-adapted b-wave amplitudes of operated eye/nonoperated eye ratios +/- SD for BSS and BSS + O2 before surgery and 1 hour, 1 day, 1 week, and 1 month after surgery were 1.02 +/- 0.10, 0.47 +/- 0.09, 0.77 +/- 0.07, 0.89 +/- 0.07, and 0.89 +/- 0.07 and 1.02 +/- 0.06, 0.62 +/- 0.16, 0.94 +/- 0.09, 0.97 +/- 0.08, and 0.96 +/- 0.06, respectively. One hour and 1 day after surgery, ERG readings for rabbits treated with BSS + O2 exhibited a statistically significantly earlier return of ERG voltage to baseline values compared with both BSS and BSS + L (P = 0.05 and P = 0.02, respectively). One day after surgery, rabbits treated with BSS alone had the lowest ERG ratios. One week and 1 month after surgery, for all solutions tested other than BSS, ERG values were within normal limits. CONCLUSION: The use of oxygenated solutions appears to affect ERG readings after pars plana vitrectomy. Further studies to evaluate the role of oxygenated solutions in different vitreoretinal surgical procedures are warranted.

Acetates↗

Fabrication, implantation, elution, and retrieval of a steroid-loaded polycaprolactone subretinal implant.

A subretinal drug delivery system was developed to overcome the limitations of current treatments for retinal disease. A rod-shaped implant was made by embedding the corticosteroid triamcinolone acetonide within a biodegradable polycaprolactone polymer matrix. The implant was fabricated by homogeneously mixing the polymer and drug in solvent. The mixture was then dried, melted, and extruded, and the prepared solid form was drawn into a filament. The rods were mechanically sectioned to a length of 2 mm with a diameter of up to 320 microm. The rods were successfully implanted into the subretinal space of six rabbits. No complications were observed during the 4-week follow-up period. Initial observations of the implantation and elution characteristics revealed that polycaprolactone is well tolerated by the retinal tissue and that the implant can elute steroid for a period of at least 4 weeks without eliciting inflammatory response or complications. In vitro drug elution rates of different polymer to drug ratios and geometries into a balanced salt solution/bovine serum albumin (1%) solution showed an early rapid-release phase and late first-order phase. Histology and device retrieval after implantation revealed minimal encapsulation and good preservation of cellular morphology during the follow-up period and a more fibrous polymer microstructure of the implant.

Absorbable Implants↗

Virtual vitreoretinal surgical simulator as a training tool.

OBJECTIVE: To demonstrate the feasibility and potential applicability of a virtual reality simulator for vitreoretinal surgery as a training and/or assessment tool. METHODS: The subjects of this study included medical students, ophthalmologic residents, and trained vitreoretinal surgeons. There were three study groups. Group I comprised 22 subjects who performed a navigation task. The time to complete the task was recorded. The relationship between the completion time, experience, and stereopsis was evaluated. Group II included 6 subjects who consecutively performed the navigation task to evaluate their learning curve. Group III included 16 subjects who performed the membrane peeling task. The number of retinal contacts and the completion time were recorded. The relationship between experience and stereopsis with the number of contacts and the completion time were evaluated. RESULTS: The average completion time in Group I for students, residents, and trained surgeons was 121.6, 92.5, and 70.6 seconds. There was a significant difference between students and trained surgeons (P = 0.004). In Group II, there was a significant decrease in the completion time with training (P = 0.001). In Group III, the average completion time for students, residents, and trained surgeons was 197, 144, and 118.2 seconds; the respective number of retinal contacts was 14, 8, and 3. There was a significant difference between students and residents (P = 0.05) and between residents and trained surgeons (P = 0.003) for the average completion time in Group III. There was a significant difference between students and trained surgeons (P = 0.003) for the number of contacts per average time and between students and residents (P = 0.05). There was a significant inverse correlation between stereopsis vision score and completion time in Group I and number of contacts per average time (P = 0.0004 and P = 0.01, respectively). CONCLUSIONS: This study demonstrates potential applications of a vitreoretinal surgical simulator as a training and skills assessment tool for novice, inexperienced, and trained surgeons. A simulator can be used to teach specific techniques and train surgeons.

Adult↗

Characteristics of visual loss by scanning laser ophthalmoscope microperimetry in eyes with subfoveal choroidal neovascularization secondary to age-related macular degeneration.

PURPOSE: To evaluate the effects of subfoveal choroidal neovascularization secondary to age-related macular degeneration on functional parameters obtained by scanning laser ophthalmoscope microperimetry. DESIGN: Retrospective observational case series and cross-sectional study. METHODS: At the Doheny Retina Institute and Wilmer Eye Institute a consecutive series of 179 eyes of 175 patients with subfoveal choroidal neovascularization secondary to age-related macular degeneration was studied. The onset of visual symptoms, best-corrected visual acuity, fluorescein angiography, evaluation of fundus microperimetry and fixation pattern using the Rodenstock scanning laser ophthalmoscope were obtained for each patient. The main outcome measures were central retinal sensitivity and fixation pattern (fixation location and fixation stability) in eyes with subfoveal choroidal neovascularization and their relationship to the length of disease, type and characteristics of choroidal neovascularization, and visual acuity. RESULTS: Of 179 eyes, 135 (75%) had central fixation, 27 (15%) had poor central fixation, and 17 (9%) had predominantly eccentric fixation. Seventy-six eyes (42%) had stable fixation, 70 eyes (39%) had relatively unstable fixation, and 33 eyes (18%) had unstable fixation. In 50 eyes (28%) a dense central scotoma was noted. Eighty-nine of 100 eyes (89%) with length of symptoms of less than 3 months had predominantly central fixation and 58 (58%) had stable fixation; 14 of 34 eyes (41%) with length of symptoms of more than 6 months had predominantly central fixation, and 5 eyes (15%) had stable fixation. In 15 eyes of patients who elected not to receive treatment, successive scanning laser ophthalmoscope microperimetry were obtained over time (follow-up of 18 months after onset of symptoms). Three months or less after the onset of symptoms, 13 eyes (87.7%) had predominantly central fixation and 9 eyes (60%) had stable fixation. More than 3 months and 6 months or less after the onset of symptoms, 10 eyes (66.7%) had predominantly central fixation and 7 eyes (46.7%) had stable fixation. This trend was further demonstrated in eyes more than 6 months after the onset of symptoms. CONCLUSIONS: We conclude that the sequence of events leading to visual function deterioration appears to involve an initial mild decrease in central retinal sensitivity and visual acuity followed by progressive fixation instability and, ultimately, development of an absolute central scotoma with totally eccentric fixation. Increased length of disease is associated with worse fixation pattern and retinal sensitivity deterioration as assessed by scanning laser ophthalmoscope microperimetry. A better understanding of the characteristics of visual loss assessed by fixation pattern evaluation and microperimetry in age-related macular degeneration may help optimize timing, patient selection, and treatment options in eyes with this condition.

Aged↗

Force comparison of air currents produced by a standard and modified infusion cannula.

OBJECTIVE: To develop and characterize an infusion cannula that reduces the intraocular jet forces created during fluid-air exchange. METHODS: A new infusion cannula was manufactured by adding a baffle 1.0 mm perpendicular to the distal opening of a 20-gauge infusion. The forces generated by the modified and standard cannulas were measured at a constant air infusion pressure of 50 mmHg by using a force sensor coupled to a schematic eye with eight radial positions from 0 degrees to 180 degrees along the circumference. Five different orientations relative to the baffle support of the modified cannula were evaluated at each position to assess the turbulent flow. RESULTS: The standard cannula produced a maximum force of 0.14 mmHg at 180 degrees from the sensor. The modified cannula generated a maximum pressure of 0.017 mmHg at 67.5 degrees from the sensor. Overall, the force from the modified cannula was an order of magnitude less than the standard infusion cannula (P < 0.01). CONCLUSIONS: The modifications of the new infusion cannula are passive with respect to its surgical performance. However, the additional baffle transforms laminar air currents into turbulent ones and allows dispersion of the jet forces, which should reduce barotrauma and desiccation of the retina during fluid-air exchange.

Biomechanical Phenomena↗

Angiographic characteristics in patients undergoing macular translocation for subfoveal choroidal neovascularization secondary to age-related macular degeneration.

PURPOSE: To review in a standardized fashion pre- and postoperative fluorescein angiographic characteristics in patients undergoing limited macular translocation (LMT) with scleral imbrication to treat subfoveal choroidal neovascularization (SFCNV) secondary to age-related macular degeneration (AMD). The current study was undertaken to assess any potential effects of the translocation procedure on altering the angiographic characteristics of SFCNV before laser photocoagulation. METHODS: A consecutive series of patients undergoing LMT for AMD was identified retrospectively. The pre- and postoperative fluorescein angiograms were reviewed in a masked fashion. Angiographic characteristics evaluated included pre- and postoperative lesion components, stability of lesion, and the amount of retinal translocation obtained. RESULTS: Eighty-eight patients (90 eyes) had angiograms of adequate quality to permit evaluation. Time between the preoperative and the prelaser angiogram ranged from 2 to 84 days (median 7.5 days). Neovascular complexes remained unchanged or decreased in size in 79% of patients. There was no statistically significant difference in lesion size between the pre- and postoperative periods (P = 0.34). Retinal movement ranged from 160 microm to 3,320 microm (median 960 microm), with 61% of cases undergoing effective translocation (i.e., the fovea was moved away from the neovascular complex). None of the lesion components or demographic factors evaluated affected the amount of translocation obtained. Larger lesions were more likely to remain subfoveal following translocation (P = 0.004). CONCLUSION: The size and lesion characteristics appear relatively stable following translocation. Amount of retinal movement is not associated with angiographic lesion characteristics. Only size was associated with achievement of desired translocation in the final model, with large lesions being less likely to achieve desired translocation. In our study group, the amount of retinal translocation was variable with 61% of cases undergoing effective translocation.

Adult↗