PubMed Health⌕ Search

Biomedical subjects

Julie A Lapos

Publications and source records attributed to Julie A Lapos.

3 recordsLinked to original sources

Rapid serial analysis of multiple oligonucleotide samples on a microchip using optically-gated injection.

Optically-gated injection of fluorescently-labeled DNA has been accomplished for the first time. Rapid, serial analysis of oligonucleotide ladders has been shown on a microchip using this injection technique. Separations of five- and six-component samples have been completed in 60 s or less with a capability to carry out serial injections of these samples every 15 s. The technique has been shown to have better than five base resolution for small oligonucleotides and excellent reproducibility in migration times (< or = 0.75% RSD). Currently, the limit of detection for the system is 0.23 microM. Additionally, multiple unique samples of DNA have been consecutively analyzed in a single separation lane using optical gating. Six consecutive injections of three different samples have been achieved with no sample carryover and a total analysis time of approximately 10 min. These results show the potential of optical gating as an alternative injection technique for high-throughput DNA applications, such as genotyping and monitoring dynamic processes.

Fluorescent Dyes↗

Parallel analysis with optically gated sample introduction on a multichannel microchip.

As an alternative to the T-type injection on microchips, optically gated sample introduction previously has been demonstrated to provide fast, serial, and reproducible injections on a single-channel microchip. Here, the ability to perform high throughput, multichannel analysis with optically gated sample introduction is described using a voice coil actuator. The microchip is fixed on a stage, which moves back and forth via the voice coil actuator, scanning two laser beams across the channels on the microchip. For parallel analysis on a multichannel microchip, both the gating beam and the probe beam are scanned at 10 Hz to perform multiple injections and parallel detection. Simultaneous, fast separations of 4-choloro-7-nitrobenzofurazan (NBD)-labeled amino acids are demonstrated in multiple channels on a microchip. Serial separations of different samples in multiple channels are also reported. Optically gated sample introduction on multiple, parallel channels shows the potential for high-speed, high-throughput separations that are easily automated by using a single electronic shutter.

4-Chloro-7-nitrobenzofurazan↗

Dual fluorescence and electrochemical detection on an electrophoresis microchip.

Simultaneous amperometric and fluorescence detection in a microfabricated electrophoresis chip is reported. Detection limits of 448 nM and 1.52, 16, and 28 microM have been achieved for dopamine, catechol, NBD-arginine, and NBD-phenylalanine, respectively. These two orthogonal detection schemes allow analysis of a wider spectrum of compounds per separation, leading to higher throughput and enabling resolution of two neutral analytes, NBD-arginine and catechol. In addition, insight into the detection and separation mechanisms is realized. Differences in migration time and peak widths between the two detectors are compared, providing a better understanding of detector alignment. A common problem encountered in electrophoresis is run-to-run migration time irreproducibility for certain samples. This novel microchip dual detection system has been utilized to reduce this irreproducibility. An unknown sample is monitored with one detector while a standard (i.e., ladder) is added to the sample and monitored simultaneously with the other detector. This dual detection method is demonstrated to normalize unknown peak mobilities in a cerebral spinal fluid sample.

4-Chloro-7-nitrobenzofurazan↗