PubMed Health⌕ Search

Biomedical subjects

Julien Carlier

Publications and source records attributed to Julien Carlier.

2 recordsLinked to original sources

Integrated microfabricated systems including a purification module and an on-chip nano electrospray ionization interface for biological analysis.

We report here on an integrated microfabricated device dedicated to the preparation of biological samples prior to their on-line analysis by electrospray ionization-mass spectrometry (ESI-MS). This microfluidic device is fabricated using the negative photoresist SU-8 by microtechnology techniques. The device includes a chromatographic module plus an ESI interface for MS. The chromatographic module is dedicated to sample purification and is based on a polymer monolithic phase which includes hydrophobic moieties. The ESI interface is integrated onto the chip and is based on a capillary slot. We present here the integration of these different modules onto a single system that is fabricated via a SU-8-based microtechnology route. We present also their testing for the purification of peptide samples. This started with a partial integration step with the combination of at least two of the modules (microsystem + monolith; microsystem + nib) and their test before the fabrication and testing of fully integrated microsystems.

Microscopy, Electron, Scanning↗

Monoliths for microfluidic devices in proteomics.

We report here on the preparation of monolithic capillary columns in view to their integration in a microsystem for on-chip sample preparation before their on-line analysis by electrospray and mass spectrometry (ESI-MS). These monolithic columns are based on polymer materials and consist of reverse phases for peptide separation and/or desalting. They were prepared using lauryl methacrylate (LMA), ethylene dimethacrylate (EDMA) as well as a suitable porogenic mixture composed of cyclohexanol and ethylene glycol. The resulting stationary phases present thus a C12-functionality. The LMA-based columns were first prepared in a capillary format using capillary tubing of 75 microm i.d. and tested in nanoLC-MS experiments for the separation of a commercial Cytochrome C digest composed of 12 peptidic fragments whose isoelectric point values and hydrophobic character cover a wide range. The LMA-based columns were capable of separating the peptidic fragments and their performances were seen to be similar as those of standard commercial columns dedicated to proteomic purposes with calculated separation efficiencies up to 145 x 10(3) plates/m. Monolithic LMA-based phases were then successfully polymerized in microchannels fabricated using the negative photoresist SU-8. After the polymerization, the systems were seen to withstand the pressures applied during the nanoLC-MS separation tests that were carried out in the same conditions as for the monolithic capillary columns. The pressure drop during these tests of the in-microchannel monoliths was as high as 50 bar; however, the separation was not as good as for a capillary format which could be accounted for by the monolith dimensions.

Amino Acid Sequence↗