PubMed Health⌕ Search

Biomedical subjects

Julio E. Pérez

Publications and source records attributed to Julio E. Pérez.

2 recordsLinked to original sources

Online Quantification of Left Ventricular Function: Correlation with Various Imaging Modalities.

The need for more objectively quantifiable evaluation of the left ventricular function, obtainable on line with echocardiography, was fulfilled through modifications of integrated backscatter imaging to permit real-time differentiation of the endocardium and the blood pool area in every image frame. Operator-guided study of individual cardiac chambers permitted instantaneous measurement of chamber areas in either the systole or diastole, with resulting physiologically meaningful recordings that relate to cardiac function. Validation studies by various approaches suggest that the methodology is clinically relevant, and further improvements in design will sharpen its applicability in the future.

Journal Article↗

Estimation of Left Ventricular Ejection Fraction by Semiautomated Edge Detection.

Left ventricular (LV) volume and ejection fraction estimation from two-dimensional echocardiograms requires off-line analysis and time-consuming manual tracing. LV volumes may be estimated on-line with a semiautomated edge detection echocardiographic system [also known as acoustic quantification (AQ)], but there are few data that compare volumes obtained from the AQ method with volumes derived from off-line manual tracing of conventional two-dimensional echocardiograms. Echocardiograms were performed in 48 patients at two medical centers. LV volumes were measured from the apical view with the method of discs and area-length formulae and from the parasternal short-axis view with the modified ellipsoid model. Based on the criterion of >/=75% endocardial visualization, 25 (52%) of the short-axis views and 14 (29%) of the apical views were analyzed by a single investigator. End-diastolic and end-systolic LV volumes derived on line with the AQ system showed a very strong linear association with off-line, manually traced volumes (r = 0.96-0.99). Correlations for ejection fraction also were strong (r = 0.90-0.96). End-diastolic and end-systolic LV volumes, measured from the apical views, were underestimated by the AQ method. However, because the error was in the same direction, ejection fractions measured with the AQ system and by manual tracing of conventional echocardiograms were similar. Estimation of ejection fraction using a semiautomated edge detection echocardiographic system is a promising method for noninvasive evaluation of systolic function in carefully selected patients.

Journal Article↗