Publications and source records attributed to Jun Okamoto.

8 recordsLinked to original sources

Navigator-echo-based MR provides high-resolution images and precise volumetry of swine livers without breath holding or injection of contrast media.

The accurate calculation of hepatic volume by computed tomography (CT) or magnetic resonance (MR) is complicated by the need for breath holding and the injection of contrast media. These are often contraindicated in patients with liver failure, and we examined the ability of unenhanced 3-dimensional (3-D) navigator-echo-based MR (NE-MR) to accurately image livers and measure volumes without breath holding compared to unenhanced (plain) or gadolinium-diethylene triamine pentaacetic acid enhanced MR (Gd-MR) in miniature swine (n = 8). Without breath holding, diaphragm movement monitoring with NE-MR reduced motion artifacts in hepatic images compared with the other modalities. Without the injection of contrast media, the signal-to-noise ratios of the images obtained using NE-MR were significantly higher than those from plain MR; Gd-MR was superior to NE-MR, however (79.5 +/- 7.5 vs. 63.2 +/- 6.0 or 97.8 +/- 8.1, respectively; P < 0.01 for each). Overall, NE-MR produced improved high-resolution liver images. Consequently, liver volumes calculated based on NE-MR images were more highly correlated with actual liver weights compared to plain or Gd-MR in the whole livers (n = 8; r = 0.937 vs. 0.835 or 0.904, respectively). Also, NE-MR demonstrated significantly strong correlation between actual weights and volumetry-calculated volumes in regenerative livers 7 days after massive hepatectomy (n = 10, r = 0.989, P < 0.01). In conclusion, our results indicate that without breath holding or the injection of contrast media, 3-D NE-MR can provide both high-resolution liver images and precise hepatic volumes in patients with liver failure due to liver surgery (massive hepatectomy and living donor liver transplantation) or fulminant hepatic failure.

Animals↗

Evaluation of the relationship between the viscoelastic stress and strain of fetal rat skin as a guide for designing the structure and dynamic performance of a manipulator for fetal surgery.

PURPOSE: To design an endoscopic manipulator for fetal surgery. The viscoelastic properties of fetal skin were estimated from both the viewpoint of mechanical structure and data collection for controlling the device. METHODS: The skin of fetal Wistar rat (19.5 days old) was set on a rheometer and the relationship between stress and strain was examined. Morphological damage was assessed histologically. RESULTS: The stress-strain curve was nonlinear and sigmoidal throughout the process. The skin fracture point was estimated to be over 4 kPa. After multiple challenges of low-level loading under 150 Pa, the curve showed no detectable change due to mechanical fatigue. Histologically, the basement membrane was not damaged even at the fracture point; however, severe damage to the dermis was observed. CONCLUSION: The viscoelastic properties of the fetal rat skin were mainly caused by the dermis and the value of the shear stress that causes skin fracture was estimated to be 4 kPa. To design a robotic stabilizer, limit of mechanical loading was thus tentatively set at 400 Pa, with a 1/10 fracture point.

Animals↗

Cardiac functional analysis by free-breath real-time cine CMR with a spatiotemporal filtering method, TSENSE: comparison with breath-hold cine CMR.

The aim of this study was to assess the accuracy of cardiac functional values obtained from free-breathing real-time cine CMR with the temporal sensitivity encoding (TSENSE) technique by comparing them with values obtained from conventional cine CMR. For the real-time cine CMR, two protocols were employed, one with good temporal resolution and one with good spatial resolution. The functional values obtained from the high temporal resolution real-time cine CMR agreed and correlated well with those of cine CMR. On the other hand, statistically significant but clinically slight overestimation of ESV (p < .05) and underestimation of EF (p < .01) were observed with the other protocol. Real-time cine CMR with TSENSE can provide acceptable cardiac functional values.

Aged↗

Alteration of brain type N-glycans in neurological mutant mouse brain.

We have previously detected two brain-specific and development-dependent N-glycans [H. Shimizu, K. Ochiai, K. Ikenaka, K. Mikoshiba, and S. Hase (1993) J. Biochem. 114, 334-338]. In the present study we attempted to analyze specific N-glycans detected in neurological mutant mice. N-glycans in cerebrum and cerebellum obtained from 3-week-old neurological mutant mice (jimpy, staggerer, and shiverer) were compared with those obtained from normal mice. N-glycans liberated from the cerebrum and cerebellum by hydrazinolysis-N-acetylation were pyridylaminated, and pyridylamino derivatives of N-glycans thus obtained were separated into neutral and five acidic fractions by anion exchange chromatography. PA-N-glycans in each fraction were compared with those obtained from normal mice by reversed-phase HPLC, and the following results were obtained. The ratio of the two brain-type N-glycans, Manalpha1-3(GlcNAcbeta1-2Manalpha1-6)(GlcNAcbeta1-4)Manbeta1-4GlcNAcbeta1-4(Fucalpha1-6)GlcNAc (BA-1) to GlcNAcbetaManalpha1-3(GlcNAcbeta1-2Manalpha1-6)(GlcNAcbeta1-4)Manbeta1-4GlcNAcbeta1-4(Fuca1-6)GlcNAc (BA-2), was higher in staggerer mice than other mutant mice and normal mice. Sia-Gal-BA-2, triantennary N-glycans, and bisected biantennary N-glycans were found in the cerebellum of shiverer and staggerer mice but not in normal or jimpy mice. High-mannose type N-glycans were not altered in mutant mice brains. The amounts of disialylbiantennary N-glycans and disialylfucosylbiantennary N-glycans were lower in jimpy mouse cerebellum than in normal mouse cerebellum, but were higher in shiverer mouse. Some alterations of N-glycans specific to mutations were successfully identified, suggesting that expression of component(s) of the N-glycan biosynthetic pathway was specifically affected in neurological mutations.

Animals↗

Activation of the primary and association auditory cortex by the transition of sound intensity: a new method for functional examination of the auditory cortex in humans.

During functional MRI image acquisition, the scanning equipment generates substantial auditory noise, the effects of which are usually ignored. To investigate the neural activity in response to the transition of noise, we measured cerebral responses to short silent periods (1 and 5 s) during which the slice readout gradients were switched off. In all 15 normal volunteers, the 1 s silence bilaterally activated the primary and association auditory cortex. Subtraction of the response to the 1 s silent period from that to the 5 s silent period revealed the activation related to the onset (transition of sound from OFF to ON) event, indicating that the 1 s response is offset (transition of sound from ON to OFF) related. The complex response of the auditory cortex to the transition of the noise should be considered in designing functional MRI with auditory tasks.

Acoustic Stimulation↗

Stepping stone sampling for retrieving artifact-free electroencephalogram during functional magnetic resonance imaging.

Ballistocardiogram and imaging artifacts cause major interference with simultaneous electroencephalogram (EEG) and functional magnetic resonance imaging (fMRI) recording. In particular, the large amplitude of the imaging artifact precludes easy retrieval of EEG signals during fMRI scanning. Recording with 20,000-Hz digitization rate combined with 3000-Hz low-pass filter revealed the real waveform of the imaging artifact, in which it was elucidated that each artifact peak precisely corresponded to each gradient component and actually had differential waveforms of the original gradient pulses. Based on this finding, to retrieve EEG signal during fMRI acquisition, a blip-type echo planar sequence was modified so that EEG sampling might be performed at every 1000 micros (digitization rate 1000 Hz) exclusively in the period in which the artifact resided around the baseline level. This method, called "stepping stone sampling," substantially attenuated the amplitude of the imaging artifact. The remnant of the artifact was subtracted from the averaged artifact waveform. In human studies, alpha activity was successfully retrieved by inspection, and its attenuation/augmentation was observed during eyes open/closed periods. Fast Fourier transform analysis further revealed that even from DC up to 120 Hz, retrieved EEG data during scanning had very similar power distributions to the data retrieved during no scanning, implying the availability of the high-frequency band of the retrieved EEG signals, including even the gamma band.

Adult↗

Measurement of in vivo local shear modulus using MR elastography multiple-phase patchwork offsets.

Magnetic resonance elastography (MRE) is a method that can visualize the propagating and standing shear waves in an object being measured. The quantitative value of a shear modulus can be calculated by estimating the local shear wavelength. Low-frequency mechanical motion must be used for soft, tissue-like objects because a propagating shear wave rapidly attenuates at a higher frequency. Moreover, a propagating shear wave is distorted by reflections from the boundaries of objects. However, the distortions are minimal around the wave front of the propagating shear wave. Therefore, we can avoid the effect of reflection on a region of interest (ROI) by adjusting the duration of mechanical vibrations. Thus, the ROI is often shorter than the propagating shear wavelength. In the MRE sequence, a motion-sensitizing gradient (MSG) is synchronized with mechanical cyclic motion. MRE images with multiple initial phase offsets can be generated with increasing delays between the MSG and mechanical vibrations. This paper proposes a method for measuring the local shear wavelength using MRE multiple initial phase patchwork offsets that can be used when the size of the object being measured is shorter than the local wavelength. To confirm the reliability of the proposed method, computer simulations, a simulated tissue study and in vitro and in vivo studies were performed.

Algorithms↗

[Single breath-hold three-dimensional MR coronary angiography with true FISP].

Single breath-hold MR coronary angiography with three-dimensional (3D) true FISP was performed in 6 volunteers. Every scan was performed in a single breath-hold, and no contrast material was used. The length of visualized vessels was 12.2 +/- 1.2 cm for the RCA and 6.6 +/- 1.1 cm for the LAD. The signal-to-noise ratio and contrast-to-noise ratio were 22.8 +/- 6.8 and 17.5 +/- 7.1, respectively. MR coronary angiography with 3D true FISP has the potential to obtain good coronary angiograms for the screening of coronary artery disease.

Adult↗