PubMed Health⌕ Search

Biomedical subjects

Junichi Doi

Publications and source records attributed to Junichi Doi.

3 recordsLinked to original sources

Effect of fluoride-releasing liner on demineralized dentin.

OBJECTIVE: The aim of this study was to evaluate the remineralization of residual demineralized dentin underneath restorations by fluoride-releasing liners in vitro. METHOD AND MATERIALS: Two glass-ionomer cement liners, Lining Cement (GC) and RK-141A (GC), and two light-cured resin liners with and without 5 wt% NaF were used in this study. The resin liners were made by mixing TEGDMA and bis-GMA. Class 5 cavities were prepared on extracted human premolars. Demineralized dentin was promoted by using a bacterial caries induction system at the cavity floor. Cavities were restored with a resin composite following application of each liner. Specimens were then stored for 4 weeks at 37 degrees C and 100% humidity. After storage, the specimens were cut through the restorations, and axial sections of about 80-microm thickness were prepared. Contact microradiographs were taken, and the radiopacity of the demineralized dentin layer underneath the liner was analyzed. RESULTS: The ratios of radiopacity of demineralized dentin under the fluoride-releasing liners were significantly higher than those under the resin liner without fluoride release. Although the amounts of fluoride release from the glass-ionomer cement liners were lower than that from the resin liner with fluoride release, there were no significant differences in the ratios of radiopacity in demineralized dentin layers among the 3 liners with fluoride release. CONCLUSION: Although the fluoride released from liners can enhance remineralization of demineralized dentin, the amount of fluoride release does not affect the ratio of radiopacity in the remineralized dentin.

Bisphenol A-Glycidyl Methacrylate↗

Bonding to root caries by a self-etching adhesive system containing MDPB.

PURPOSE: To evaluate the bonding of an experimental antibacterial fluoride-releasing adhesive system (ABF) to normal and carious dentin in human teeth with Class V root caries. METHODS: Mesiodistal sectioning removed the buccal enamel, superficial dentin and much of the carious dentin in 21 extracted human bicuspids with root surface caries. The surfaces of normal coronal and root dentin, and caries-affected and caries-infected dentin were ground with wet 600-grit SiC paper to create a standardized smear layer. Tooth surfaces were treated with the ABF according to manufacturer's instructions, and then covered with excess resin composite. After immersion in 37 degrees C water for 24 hours, the restored teeth were horizontally sectioned into serial slabs that were trimmed into hourglass shapes to isolate the bonded area to the test substrates, and then their bond strengths were measured by the microtensile bond test, and the interfaces examined by SEM and TEM. The bond strengths were statistically compared with ANOVA and Fisher's PLSD (P < 0.05). RESULTS: The bond strengths of ABF to caries-affected and caries-infected dentin were significantly lower than those to normal coronal and root dentin. SEM micrographs revealed that the hybrid layers in caries-affected and caries-infected dentin were more porous compared to the hybrid layer in normal coronal and root dentin. TEM micrographs showed that bacteria that had invaded the dentin were embedded in this adhesive monomer in caries-infected dentin. CLINICAL SIGNIFICANCE: Although the bond strength of ABF adhesive system to root carious dentin is lower than that of normal dentin, the antibacterial and fluoride-releasing properties of ABF may contribute to prevent caries progression and inhibit secondary caries.

Acid Etching, Dental↗

Resin adhesion to carious dentin.

PURPOSE: To investigate the microtensile bond strength (microTBS) of a self-etching priming adhesive system to normal, caries-affected and caries-infected dentin, and to observe the ultrastructure of the resin-dentin interface by transmission electron microscopy (TEM). MATERIALS AND METHODS: Twelve extracted human molar teeth with deep occlusal caries were stained with caries detector solution and ground flat occlusally. The red-stained soft dentin was classified as caries-infected. The surrounding discolored dentin was classified as caries-affected dentin. The surrounding normal dentin served as a control. The entire flat surface was bonded with Clearfil Liner Bond 2V (CV) and covered with resin composite to form a composite crown 5 mm high. One day later the specimens were serially sectioned vertically into multiple slabs 0.8 mm thick. Under microscopic observation, the specimens were divided into normal or caries-infected or caries-affected dentin. These regions were isolated by cutting away the remaining dentin to form hour-glass shapes with the smallest surface area at the test site. After measuring the areas, the specimens were fixed to a microtensile tester and pulled under tension to failure. Additional slabs that were not used for bond strength tests were processed for TEM. Bond strength data were analyzed by Kruskal-Wallis one-way ANOVA and Student-Newman-Keuls multiple comparisons. RESULTS: The microTBS of CV to normal, caries-affected and caries-infected dentin were 45 +/- 10 MPa, 30 +/- 10 MPa, 10 +/- 5 MPa, respectively. TEM images showed that CV formed thin hybrid layers that were less than 1 microm thick in normal dentin, but that were between 6-8 microm thick in caries-affected dentin. Bacteria were only sparsely observed in the dentin tubules of bonded caries-affected dentin. However, in caries-infected dentin, an unusual interface was seen in which carious bacteria within disorganized non-banded collagen fibrils could be seen embedded by the adhesive. The hybrid layer in caries-infected dentin was found to be 30-60 microm thick.

Acid Etching, Dental↗