PubMed Health⌕ Search

Biomedical subjects

Juozas Kulys

Publications and source records attributed to Juozas Kulys.

4 recordsLinked to original sources

Laccase-catalysed iodide oxidation in presence of methyl syringate.

The kinetics of potassium triiodide (KI(3)) formation during fungal laccase action was investigated in presence of methyl syringate (MS). The recombinant forms of Polyporus pinsitus (rPpL), Myceliophthora thermophila (rMtL), Coprinus cinereus (rCcL), and Rhizoctonia solani (rRsL) laccases were used. The triiodide formation rate reached 6.1, 5.5, 6.0, and 2.1 microM/min at saturated rPpL, rCcL, rRsL, and rMtL concentration, respectively, in acetate buffer solution pH 5.5 and in presence of 10 microM of MS and 1 mM of potassium iodide. The triiodide formation rate increased if pH decreased from 6.5 to 4.5. The scheme of laccase-catalysed iodide oxidation includes stadium of MS interaction with oxidized laccase with concomitant production of MS(ox). The reaction of MS(ox) with iodide produced triiodide. The turnover number of MS was 93 and 44 at pH 5.5 for rPpL and rMtL, respectively. The scheme also contained a stadium of reversible reduction of laccase active centre with the mediator explaining the different saturation rate of triiodide production. The fitting kinetic data revealed that the reversibility of the reaction increased for laccases containing lower redox potential of copper type I.

Ascomycota↗

Synergistic substrates determination with biosensors.

High sensitive biosensors for heterocyclic compounds determination were built using oxidases-catalyzed hexacyanoferrate(III) reduction in the presence of these compounds. As oxidases Aspergillus niger glucose oxidase and recombinant Microdochium nivale carbohydrate oxidase were used. The biosensors were build using graphite electrodes and entrapped solution of the oxidases. The sensitivity of the biosensors achieves 5.2-14.5 microA microM-1 cm-2. The detection limit of some heterocyclic compounds was 0.2 microM. The sensitivity of biosensors was 300-10,000 times larger in comparison to hexacyanoferrate(III). To background the scheme of biosensors action kinetics of synergistic substrates oxidation was investigated in homogenous solution. The measurements showed that the rate of the reduction of low reactive substrate (hexacyanoferrate(III)) increased due to synergistic action of high reactive substrates (oxidized heterocyclic compounds). The modeling revealed the limiting step of the process. The increase of hexacyanoferrate(III) reduction rate is determined by the rate of reduced enzymes interaction with oxidized heterocyclic compound. The oxidation of heterocyclic compounds (mediators) with hexacyanoferrate(III) does not limit the process. The analysis of macrokinetics of biosensors action showed that synergistic effect may be realized and high biosensors sensitivity may be achieved if diffusion module of the enzyme reaction with the oxidized mediator and of a cross reaction is larger than 0.5. The calculated relative sensitivity is about three times higher in comparison to experimentally determined that may be caused by the limited stability of oxidized heterocyclic compounds and/or some external diffusion limitation of substrates.

Aspergillus niger↗

Modelling amperometric enzyme electrode with substrate cyclic conversion.

A mathematical model of amperometric enzyme electrodes in which chemical amplification by cyclic substrate conversion takes place in a single enzyme membrane has been developed. The model is based on non-stationary diffusion equations containing a non-linear term related to Michaelis-Menten kinetic of the enzymatic reaction. The digital simulation was carried out using the finite difference technique. The influence of the substrate concentration, the maximal enzymatic rate as well as the membrane thickness on the biosensor response was investigated. The numerical experiments demonstrate significant (up to dozens of times) gain in biosensor sensitivity at low concentrations of substrate when the biosensor response is under diffusion control.

Biosensing Techniques↗

Amperometric biosensors based on recombinant laccases for phenols determination.

Graphite (GE) or printed graphite electrode (PGE) based biosensors containing recombinant fungal laccase Polyporus pinsitus (rPpL), and Myceliophthora thermophila (rMtL) were developed. The enzymes were immobilized using bovine serum albumin and glutaraldehyde. At pH 5.5 and -0.1 V, the calibration graphs of GE based biosensors were hyperbolic if pyrocatechol was used. The concentration of substrate that results in 50% of steady-state response (EC(50)) was 0.7 mM and sensitivity (S) was 3.8 mA/M. The sensitivity increased up to 4 A/M if larger amount of rPpL was used. The sensitivity of biosensors changed little during 9 days of exploitation, but decreased at longer time. The PGE based biosensors were mounted into the flow-through cell and calibrated under kinetic regime. EC(50) of the biosensors containing rPpL varied from 0.6 to 4.0 mM and sensitivity varied from 0.11 to 1.9 mA/M. The response of biosensor containing thermostable laccase rMtL was less, but response saturated at larger pyrocatechol concentration. The sensitivity changed little during 6 days. Both type of biosensors responded also to 1-naphthol, o-phenylenediamine, guaiacol, o-anizidine, benzidine. The experiments demonstrate recombinant laccases application to biosensor engineering and their use to phenol and related compound determination under steady-state and flow-through regimes.

Adsorption↗