Microtechnology: meet neurobiology.

The field of neuroscience has always been attractive to engineers. Neurons and their connections, like tiny circuit elements, process and transmit information in a dramatic way that is intimately curious to researchers in the computer science and engineering fields. Of particular interest has been the recent push in applying microtechnology to the field of neuroscience. This review is meant to provide an overview of some of the subtle nuances of the nervous system and outline recent advances in lab on a chip applications in neurobiology. It also aims to highlight some of the challenges the field faces in the hopes of encouraging new engineering researchers to collaborate with neurobiologists to help advance our basic understanding of the nervous system and create novel applications based on neuroengineering principles.

Animals↗

ECoG factors underlying multimodal control of a brain-computer interface.

Most current brain-computer interface (BCI) systems for humans use electroencephalographic activity recorded from the scalp, and may be limited in many ways. Electrocorticography (ECoG) is believed to be a minimally-invasive alternative to electroencephalogram (EEG) for BCI systems, yielding superior signal characteristics that could allow rapid user training and faster communication rates. In addition, our preliminary results suggest that brain regions other than the sensorimotor cortex, such as auditory cortex, may be trained to control a BCI system using similar methods as those used to train motor regions of the brain. This could prove to be vital for users who have neurological disease, head trauma, or other conditions precluding the use of sensorimotor cortex for BCI control.

Adult↗

Multi-site incorporation of bioactive matrices into MEMS-based neural probes.

Methods are presented to incorporate polymer-based bioactive matrices into micro-fabricated implantable microelectrode arrays. Using simple techniques, hydrogels infused with bioactive molecules are deposited within wells in the substrate of the device. This method allows local drug delivery without increasing the footprint of the device. In addition, each well can be loaded individually, allowing spatial and temporal control over diffusion gradients in the microenvironment of the implanted neural interface probe. In vivo testing verified the following: diffusion of the bioactive molecules, integration of the bioactive molecules with the intended neural target and concurrent extracellular recording using nearby electrodes. These results support the feasibility of using polymer gels to deliver bioactive molecules to the region close to microelectrode shanks. This technique for microdrug delivery may serve as a means to intervene with the initial phases of the neuroinflammatory tissue response to permanently implanted microelectrode arrays.

Animals↗

Visualization of the intact interface between neural tissue and implanted microelectrode arrays.

This research presents immunohistochemical strategies for assessing the interactions at the immediate interface between micro-scale implanted devices and the surrounding brain tissue during inflammatory astrogliotic reactions. This includes preparation, microscopy and analysis techniques for obtaining images of the intimate contact between neural cells and the surface of implantable micro-electromechanical systems (MEMS) devices. The ability to visualize the intact interface between an implant and the surrounding tissue allows researchers to examine tissue that is unchanged from its native implanted state. Conversely, current popular techniques involve removing the implant. This tends to cause damage to the tissue immediately surrounding the implant and can hinder one's ability to differentiate inflammatory responses to the implant versus physical damage occurring from removal of the implant from the tissue. Due to advances in microscopy and staining techniques, it is now possible to visualize the intact tissue-implant interface. This paper presents the development of imaging techniques for visualizing the intact interface between neural tissue and implanted devices. This is particularly important for understanding both the acute and chronic neuroinflammatory responses to devices intended for long-term use in a prosthetic system. Non-functional, unbonded devices were imaged in vitro and in vivo at different times post-implantation via a range of techniques. Using these techniques, detailed interactions could be seen between delicate cellular processes and the electrode surface, which would have been destroyed using conventional histology processes.

Animals↗

Access to trauma centers in the United States.

CONTEXT: Previous studies have reported that the number and distribution of trauma centers are uneven across states, suggesting large differences in access to trauma center care. OBJECTIVE: To estimate the proportion of US residents having access to trauma centers within 45 and 60 minutes. DESIGN AND SETTING: Cross-sectional study using data from 2 national databases as part of the Trauma Resource Allocation Model for Ambulances and Hospitals (TRAMAH) project. Trauma centers, base helipads, and block group population were counted for all 50 states and the District of Columbia as of January 2005. MAIN OUTCOME MEASURES: Percentages of national, regional, and state populations having access to all 703 level I, II, and III trauma centers in the United States by either ground ambulance or helicopter within 45 and 60 minutes. RESULTS: An estimated 69.2% and 84.1% of all US residents had access to a level I or II trauma center within 45 and 60 minutes, respectively. The 46.7 million Americans who had no access within an hour lived mostly in rural areas, whereas the 42.8 million Americans who had access to 20 or more level I or II trauma centers within an hour lived mostly in urban areas. Within 45 and 60 minutes, respectively, 26.7% and 27.7% of US residents had access to level I or II trauma centers by helicopter only and 1.9% and 3.1% of US residents had access to level I or II centers only from trauma centers or base helipads outside their home states. CONCLUSION: Selecting trauma centers based on geographic need, appropriately locating medical helicopter bases, and establishing formal agreements for sharing trauma care resources across states should be considered to improve access to trauma care in the United States.

Air Ambulances↗

Dynamic control of extracellular environment in in vitro neural recording systems.

A technique is presented for rapid fabrication of microfluidic channels on top of multichannel in vitro neural recording electrode arrays. The channels allow dynamic control of both stable and transient flow patterns over localized areas of the array, over biologically relevant timescales. A cellular model consisting of thermally sensitive dorsal root ganglion neurons was integrated into the devices. The device was used to demonstrate precise control of the extracellular microenvironment of individual cells on the array. Since the methods presented here are not specific to a particular cell type or neural recording system, the technique is amenable to a wide range of applications within the neuroscience field.

Animals↗

Integrated microelectrode array and microfluidics for temperature clamp of sensory neurons in culture.

A device for cell culture is presented that combines MEMS technology and liquid-phase photolithography to create a microfluidic chip that influences and records electrical cellular activity. A photopolymer channel network is formed on top of a multichannel microelectrode array. Preliminary results indicated successful local thermal control within microfluidic channels and control of lamina position over the electrode array. To demonstrate the biological application of such a device, adult dissociated dorsal root ganglion neurons with a subpopulation of thermally-sensitive cells are attached onto the electrode array. Using laminar flow, dynamic control of local temperature of the neural cells was achieved while maintaining a constant chemical culture medium. Recording the expected altered cellular activity confirms the success of the integrated device.

Action Potentials↗

Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex.

An important aspect of the development of cortical prostheses is the enhancement of suitable implantable microelectrode arrays for chronic neural recording. The objective of this study was to investigate the recording performance of silicon-substrate micromachined probes in terms of reliability and signal quality. These probes were found to consistently and reliably provide high-quality spike recordings over extended periods of time lasting up to 127 days. In a consecutive series of ten rodents involving 14 implanted probes, 13/14 (93%) of the devices remained functional throughout the assessment period. More than 90% of the probe sites consistently recorded spike activity with signal-to-noise ratios sufficient for amplitudes and waveform-based discrimination. Histological analysis of the tissue surrounding the probes generally indicated the development of a stable interface sufficient for sustained electrical contact. The results of this study demonstrate that these planar silicon probes are suitable for long-term recording in the cerebral cortex and provide an effective platform technology foundation for microscale intracortical neural interfaces for use in humans.

Action Potentials↗

Silicon-substrate intracortical microelectrode arrays for long-term recording of neuronal spike activity in cerebral cortex.

This study investigated the use of planar, silicon-substrate microelectrodes for chronic unit recording in the cerebral cortex. The 16-channel microelectrodes consisted of four penetrating shanks with four recording sites on each shank. The chronic electrode assembly included an integrated silicon ribbon cable and percutaneous connector. In a consecutive series of six rats, 5/6 (83%) of the implanted microelectrodes recorded neuronal spike activity for more than six weeks, with four of the implants (66%) remaining functional for more than 28 weeks. In each animal, more than 80% of the electrode sites recorded spike activity over sequential recording sessions during the postoperative time period. These results provide a performance baseline to support further electrode system development for intracortical neural implant systems for medical applications.

Action Potentials↗