Estimation-induced correlations of the Zernike coefficients of the eye aberration.

The statistical properties of the estimated eye aberrations differ in general from the actual ones owing to the cross coupling and aliasing generated in the estimation process. In particular, the estimated Zernike aberration coefficients may show fictitious correlations that are not present in the incoming wavefronts. This fact should be taken into account when analyzing estimated aberration datasets, searching for correlations related to physiological eye features. We give an analytical model for this effect and evaluate its magnitude for a particular example, assuming that the true aberration statistics follows a Kolmogorov power law.

Journal Article↗

Translational and rotational pupil tracking by use of wavefront aberration data and image registration techniques.

We present a methodology with which to evaluate translations and rotations of wavefront aberration measurements of systems in which the exit pupil suffers displacements and rotations with respect to the reference frame of the measuring device. We propose to use image registration techniques to account for rotations, translations, and scale changes of the pupil. We present a proof of principle, using an artificial eye in addition to computer simulations. The method is software based and requires no additional hardware.

Algorithms↗

Direct transformation of Zernike eye aberration coefficients between scaled, rotated, and/or displaced pupils.

In eye aberrometry it is often necessary to transform the aberration coefficients in order to express them in a scaled, rotated, and/or displaced pupil. This is usually done by applying to the original coefficients vector a set of matrices accounting for each elementary transformation. We describe an equivalent algebraic approach that allows us to perform this conversion in a single step and in a straightforward way. This approach can be applied to any particular definition, normalization, and ordering of the Zernike polynomials, and can handle a wide range of pupil transformations, including, but not restricted to, anisotropic scalings. It may also be used to transform the aberration coefficients between different polynomial basis sets.

Computer Simulation↗

A new calibration set of phase plates for ocular aberrometers.

PURPOSE: To manufacture and test a set of phase plates for the calibration of ocular aberrometers and apply it to the calibration of an ocular laser ray tracing aberrometer. METHODS: The set of phase plates is made by a greyscale single-mask photosculpture in photoresist method. Each plate induces a given amount of a particular aberration (Zernike) mode. The set contains two subsets: 1) pure Zernike modes to test the accuracy among different orders (from 3rd to 7th, approximately 0.3 to 0.4 microm); and 2) plates having different amounts of the same mode, 3rd order coma ranging from 0.11 to 0.47 microm. After manufacturing, the plates were tested twice, as a crosscheck, measuring the aberration pattern of each plate with a Mach-Zehnder interferometer and a single-pass Hartmann-Shack wavefront sensor. The set was then applied to the calibration of an ocular double-pass laser ray tracing aberrometer. RESULTS: Close agreement was found between the three types of measurement. The maximum difference between Hartmann-Shack and laser ray tracing measurements was 0.032 microm (ie, approximately lambda/20, half of the typical measuring error in human eyes). This permitted detection of a small bias in the ocular laser ray tracing aberrometer. CONCLUSIONS: The calibration set may be a powerful tool for the assessment of accuracy and reliability in ocular aberrometry. It discovered a small bias, which is almost impossible to detect when working with human eyes or trial lenses. This type of calibration tool is especially important in clinical environments.

Calibration↗

Influence of thresholding on centroid statistics: full analytical description.

The centroid method is a common procedure for subpixel location that is applied to a large number of optical sensors. In practice, it is always accompanied by thresholding algorithms used to eliminate undesirable background that may decrease precision. We present a full analytical description of the interaction between centroiding and thresholding applied over an intensity distribution corrupted by additive Gaussian noise. An in depth analysis of the most outstanding statistical properties of this relation (mean and variance) is also presented by means of simulated and experimental data. This work provides fundamental concepts to the designers of sensors that are based on centroid measurements to allow them to use thresholding correctly before centroid computation.

Journal Article↗

Least-squares modal estimation of wrapped phases: application to phase unwrapping.

Phase unwrapping continues to be an important step in those techniques that obtain the phase from Fourier transforms. We propose a fast two-dimensional phase-unwrapping algorithm that has been specially designed to be used as part of an iterative algorithm. It can be used also as a final step of a phase retrieval process with other unwrapping techniques. The algorithm consists of a modal least-squares estimation of the wrapped phase by using as inputs to the linear estimation the derivative of the wrapped phase. A theoretical description of the method, simulations, and experimental validations are presented.

Journal Article↗