PubMed Health⌕ Search

Biomedical subjects

Jyh-Myng Zen

Publications and source records attributed to Jyh-Myng Zen.

15 recordsLinked to original sources

Fast differentiation of meats from fifteen animal species by liquid chromatography with electrochemical detection using copper nanoparticle plated electrodes.

A simple, rapid and reliable method based on high-performance liquid chromatography with electrochemical detection was developed to routinely differentiate among meat products from fifteen food animal species. Samples from cattle, pigs, goats, deer, horses, chickens, ducks, ostriches, salmon, cod, shrimp, crabs, scallops, bullfrogs and alligators each exhibited unique electrochemical profiles. Species-specific markers exhibited reproducible peak retention times with coefficients of variation less then 6% across different runs, body regions and subjects. The method requires no derivatization or extraction steps and may be applicable to fresh or cooked meats. Incubation of fresh beef, pork or chicken at room temperature for 24h or repeated freezing and thawing changed the intensity but not the pattern of species-specific peaks. In conclusion, this method appears suitable for rapid differentiation of meats from various food animal species and demonstrates the utility of electrochemical detection to supplement existing immunochemical and molecular biological methods. The possibility of using this method to detect adulteration and degradative changes of meat proteins is discussed.

Animals↗

Disposable electrochemical sensor for determination of nitroaromatic compounds by a single-run approach.

Environmental and security applications have generated major demands for effective field-deployable tools for detecting nitroaromatic compounds, such as chloramphenicol (an antibiotic), parathion (an organophosphate nerve agent), and TNT (2,4,6-trinitrotoluene, an explosive) in a fast, simple, sensitive, reliable, and cost-effective manner. We report here a single-run approach for such a purpose. The reduction potential of different nitroaromatic compounds was found to systematically shift with the substituent group at an electrochemically preanodized screen-printed carbon electrode. The preanodization treatment makes the peak sharp and hence provides a precise way to identify the substituent effect on nitroaromatic compounds. By using potential shifts as analytical characteristics of nitroaromatic compounds, a suitable internal standard can be chosen based on the criteria of well-separated peak potential and rarely found in the real sample of interest. Simply by measuring the ratio of peak currents between analytes of interest and internal standard, the analysis can be done in a single-run measurement. Both the matrix effect and the variation of electrode during the preparation process can be canceled out in this approach and thus allows for a high-precision analysis. Just by placing a 20-microL drop on a single-use amperometric sensor strip incorporating a three-electrode configuration is enough for rapid and sensitive detection of nitroaromatic compounds by square-wave voltammetry. For example, the linear detection range can be up to 100 microM with a detection limit of 0.42 microM (S/N = 3) in the detection of chloramphenicol. This approach was successfully demonstrated in real sample analysis to verify the applicability of the method. The promising performances open new possibilities for rapid determination of nitroaromatic compounds in environmental and biological samples.

Calibration↗

An electrochemical cell coupled with disposable screen-printed electrodes for use in flow injection analysis.

An electrochemical cell coupled with disposable screen-printed electrodes (SPEs) that is specifically designed for use in flow injection analysis (FIA) is described in this study. The cell is made of foldable polyoxymethylene (acetal) thick platelets with the bottom portion consisting of a cavity track to drag the SPEs in position and the top portion having predrilled T-like holes to arrange the Ag/AgCl reference electrode and stainless steel inlet & outlet. An "O ring" is suitably fixed on the top of the working electrode to form a thin-layer space where the electrochemical reaction can take place. Hydrodynamic characterization was validated by using a benchmark hexacyanoferrate redox couple. The results of practical analysis of glucose in human plasma clearly demonstrate the characteristics and applicability of the proposed wall-jet electrochemical cell in FIA.

Blood Glucose↗

Precise blood lead analysis using a combined internal standard and standard addition approach with disposable screen-printed electrodes.

We report here a highly accurate and efficient method for blood lead analysis (BLA) through the use of a disposable electrode. A new type of mercury-plated preanodized screen-printed carbon electrode, together with a thallium(III) internal standard, simplifies calibration and gives easily quantifiable signals for accurate BLA. A preanodization procedure improves the preconcentration ability of the working electrode through the effect of lead (Pb) complexing with an electrogenerated surface functional group, mainly >C=O. Under optimized conditions, the ratio of the anodic stripping peak currents of Pb and Tl (i.e., i(Pb)/i(Tl)) is linear against [Pb] in the window of 1-300 ppb with a correlation coefficient and detection limit (signal-to-noise ratio=3) of 0.999 and 0.23 ppb, respectively. This approach was used to analyze blood samples (n=55) from workers at a local battery factory. The results are consistent with those obtained from graphite furnace atomic absorption spectroscopy and confirm the applicability of the proposed method.

Carbon↗

A new fabrication process for a microchip electrophoresis device integrated with a three-electrode electrochemical detector.

We report here a novel and simple process for the fabrication of a poly(methyl methacrylate) (PMMA)-based microchip electrophoresis device, integrated with a screen-printed three-electrode electrochemical detector that does not require a replicate mold. In this approach, a photoresist layer constitutes both an adhesion layer and side walls of 50 mum wide and 50 mum tall microfluidic channels on a screen-printed three-electrode PMMA substrate. Openings were drilled for buffer reservoirs on an additional piece of PMMA, then the final device was bonded in a PMMA/photoresist/PMMA sandwich configuration. This process is inexpensive, less time-consuming, and simpler compared with traditional fabrication methods. The combination of this PMMA-based microchip fabrication together with screen-printed electrode technology holds great promise for the mass production of a single-use micrototal analytical system. Successful determination of uric acid and L-ascorbic acid with the presented system validates its utility. In combination with a suitable electrochemical detector, this device holds much promise for the determination of other analytes in various biological samples for medical and clinical diagnosis.

Ascorbic Acid↗

Amino acid analysis using disposable copper nanoparticle plated electrodes.

A disposable copper nanoparticle-plated screen-printed carbon electrode (designated as Cun-SPE(100-nm)) provides a new material for the determination of native amino acids. All 20 underivatized amino acids can be sensitively determined at 0.0 V vs. Ag/AgCl in pH 8 phosphate buffer solution. The precisely controlled copper nanoparticles can boost up the CuIIO/CuI2O redox signal on the working surface without any prior pretreatment procedure. The formation of a reversible 1:1 CuIIO-amino acid complex on the Cun-SPE(100-nm) was proposed to play a key role in the reaction mechanism. Stable detection responses were obtained for all amino acids by flow injection analysis with detection limits (S/N = 3) that lie in the range of 24 nM-2.7 microM. Selected amino acids from six representative chemical natures were separated by HPLC and detected at the Cun-SPE(100-nm) with promising results.

Amino Acids↗

Voltammetric peak separation of dopamine from uric acid in the presence of ascorbic acid at greater than ambient solution temperatures.

Peak overlap in voltammetry poses challenges for the quantitative analysis of electroactive species. Dopamine and uric acid are typically challenging to determine voltammetrically because of their very similar oxidation peak potentials. We report preliminary results of the use of a screen-printed carbon electrode for the determination of dopamine and uric acid in an electrolyte solution maintained above ambient temperatures. Higher temperatures resulted in dramatic shifting of the dopamine oxidation peak toward lower potentials, while the uric acid peak was essentially stationary. Ascorbic acid, an interference in voltammetric uric acid determinations, is effectively suppressed at higher temperatures. This resulted in a greater peak separation of dopamine from uric acid at higher temperatures, which is desirable for better peak integration. In addition, greater current responses for both species were recorded at higher temperatures. The cause for such an increase in peak current is unraveled using ac impedance measurements. Presented are preliminary results for determining dopamine and uric acid at temperatures higher than ambient. Much improved voltammetric peak separation and sensitivity is obtained at these higher temperatures compared to ambient.

Ascorbic Acid↗

Photoelectrocatalytic oxidation of o-phenols on copper-plated screen-printed electrodes.

A novel and sensitive detection method based on photoelectrocatalytic oxidation of o-diphenols was demonstrated on a copper-plated screen-printed carbon electrode (designated CuSPE) in pH 8 phosphate buffer solution. The o-diphenols can be detected amperometrically through electrochemical oxidation at a low applied potential of -0.1 V versus Ag/AgCl, where the CuSPE is much less subject to interfering reactions. The mechanism that induces good selectivity of the CuSPE is explained in terms of the formation of a cyclic five-member complex intermediate (Cu(II)-o-quinolate). A prototype homemade flow through cell design is described for incorporating the photoelectrode and light source. Electrode irradiation results in a large increase in anodic current. The oxidative photocurrents produced by irradiation increase with light intensity presumably because of the formation of semiconductor Cu(2)O. The principle used in this study has an opportunity to extend into various research applications.

Journal Article↗

Flow injection analysis of an ultratrace amount of arsenite using a Prussian blue-modified screen-printed electrode.

We report here a new electrochemical method for the selective detection of ultratrace amount of arsenite (AsO(2)(-), As(3+)) using a Prussian blue-modified screen-printed electrode (designated as PBSPE) by flow injection analysis (FIA) in 0.1 M, pH 4 KCl/HCl carrier solution. The Prussian yellow/Prussian blue redox couple of the PBSPE was found to mediate the As(3+) oxidation. Various factors influencing the determination of As(3+) were thoroughly investigated in this study. Under the optimized FIA conditions, a linear calibration plot in the range of 50 nM-300 microM with a detection limit (S/N = 3) of 25 nM (i.e., 64.9 pg in 20-microL loop) was observed at an operation potential of +0.6 V vs Ag/AgCl. The sensitivity was good enough to detect arsenite at levels lower than the current EPA standard. This modified electrode showed good resistance to interference from common ions, especially Cl(-), which is generally considered as a major interference in the determination of As(3+) by ICPMS. The practical utility of the PBSPE to detect As(3+) was demonstrated in "blackfoot" disease endemic village groundwater from the southwestern coast area of Taiwan (Pei-Men).

Journal Article↗

A glucose biosensor employing a stable artificial peroxidase based on ruthenium purple anchored cinder.

Iron-enriched industrial waste cinder (CFe*) has been recycled for efficient and stable anchoring of Ru(CN)6(4-) to the formation of a hybrid ruthenium purple complex. The cinder/ruthenium purple hybrid-modified carbon paste electrode (designated as CPE/CFe*-RP) was worked out for hydrodynamic analysis of H2O2 at a low detecting potential of 0.0 V versus Ag/AgCl in pH 7 ammonium buffer solution. The highly active, selective, and stable electrocatalytic system with a function similar to peroxidase enzyme shows a linear calibration curve up to 0.8 mM H2O2 at a rotation rate of 3600 rpm with slope and detection limit (S/N = 3) of 0.11 microA/microM and 33 nM, respectively. Interference by direct electrochemical oxidation of easily oxidizable substances can be prevented as a result of the low detecting potential of the working system. A glucose biosensor was further constructed by coating with glucose oxidase and Tosflex on the CPE/CFe*-RP (denoted as CPE/CFe*-RP/GOx/Ts). The proposed CPE/CFe*-RP/GOx/Ts with a two-layer configuration, that is, enzyme and protecting layers, exhibits good operational performance in terms of response time, linearity, detection limit, and lifetime.

Aspergillus niger↗

Photoelectrochemical oxygen sensor using copper-plated screen-printed carbon electrodes.

We report here an efficient photocatalytic amperometric sensor for the determination of dissolved oxygen (DO) in phosphate buffer solution using a disposable copper-plated screen-printed carbon electrode (CuSPE). The photoelectrochemical activity toward DO of the CuSPE was related to the formation of a p-type semiconductor Cu(I)2O. The solution pH and biased potential (E(bias)) were systematically optimized as pH 8 PBS and -0.7 V vs Ag/AgCl, respectively. Under optimized conditions, the calibration plot was linear in the range of 1-8 ppm with sensitivity and regression coefficient of 23.51 (microA cm2)(-1) ppm(-1) and 0.9982, respectively. The reproducibility of the system was good with seven successive measurements of DO yielding a RSD value of 1.87%. Real sample assays for groundwater and tap water were also consistent with those measured by a commercial DO meter. The principle used in DO measurement has an opportunity to extend into various research fields.

Carbon↗

Selective detection of o-diphenols on copper-plated screen-printed electrodes.

Selective detection of o-diphenols (e.g., catechol, dopamine, and pyrogallol) in the presence of simple phenols, m- and p- derivative diphenols, and ascorbic acid has been demonstrated on copper-plated screen-printed electrodes (CuSPEs) in pH 7.4 phosphate buffer solution. The CuSPE showed an unusual catalytic response at -0.05 V versus Ag/AgCl selectively to o-diphenolic compounds. The o-diphenols can thus be determined amperometrically through direct electrochemical oxidation in low potentials (approximately 0 V), where the CuSPE is much less subject to interfering reactions. Such a catalytic phenomenon cannot be observed on conventional Pt and glassy carbon electrodes. The selective mechanism is explained in terms of the formation of cyclic five-member complex intermediate (Cu(II)-o-quinolate). Most important of all, the common drawbacks of electrode fouling through polymerization were completely overcome in this system.

Ascorbic Acid↗