PubMed Health⌕ Search

Biomedical subjects

K A Frankel

Publications and source records attributed to K A Frankel.

At least 19 recordsLinked to original sources

Elevated picture completion scores: a possible indicator of hypervigilance in maltreated preschoolers.

OBJECTIVE: The Picture Completion subtest of the Wechsler Preschool and Primary Scales of Intelligence-Revised (WPPSI-R) measures visual alertness and the ability to differentiate essential from nonessential details. In children who are hypervigilant as a result of maltreatment, these skills may be over-functioning. It was hypothesized that the Picture Completion subtest scores of these children would be significantly elevated in comparison to their other nonverbal scores and their overall intellectual functioning. METHOD: Fourteen children from a therapeutic day treatment preschool program for maltreated children were administered the WPPSI-R. Standardized discrepancy scores between Picture Completion scores and Performance mean scores (PC-Performance Discrepancy) and the mean of all subscale scores (PC-Overall IQ Discrepancy) were formed and then analyzed. RESULTS: The abused preschoolers scored significantly lower than the population mean on four of the five WPPSI-R Performance subscales. Only on Picture Completion did they score significantly higher. Average PC-Performance Discrepancy and PC-Overall IQ Discrepancy scores were greater than one, indicating that the mean difference of children's Picture Completion score from either their Performance mean score or all of their mean scores was more than one standard deviation. CONCLUSION: Elevated Picture Completion score may serve as a marker for hypervigilance and/or PTSD in children with histories of maltreatment.

Arousal↗

Microsurgical resection of incompletely obliterated intracranial arteriovenous malformations following stereotactic radiosurgery.

Radiosurgery is effective in obliterating small arteriovenous malformations (AVMs), but less successful in thrombosing larger AVMs. This study reviewed patients who underwent surgical resection of their large AVMs following failed radiosurgical obliteration. AVMs from 36 patients (aged 7 to 64 years, mean 29.9) were surgically resected 1 to 11 years after radiosurgery. Initial AVM volumes were 0.7 to 117 cm3 (mean 21.6 cm3), and radiosurgical doses ranged from 4.6 to 45 Gray equivalent (GyE) (mean 21.1 GyE). Thirty AVMs (83%) were located in eloquent tissue. Venous drainage was deep (14), superficial (13), or both (9). Spetzler grades were II (2), III (12), IV (18), and V (4). Nine patients suffered rehemorrhage after radiosurgery but prior to surgery, while three patients developed radiation necrosis. Twenty-seven patients underwent endovascular embolization prior to surgery. During microsurgical resection, the AVMs were found to be significantly less vascular and more easily resected, compared to AVMs in patients who had not received radiosurgery. Histology showed endothelial proliferation with hyaline and mineralization in vessel walls. Partial or complete thrombosis of some AVM vessels, and evidence of vessel and brain necrosis were noted in many cases. Clinical outcome was excellent or good in 34 cases, with two patients dying of rebleeding from residual AVM. Five patients were neurologically worse following microsurgical resection. Final outcome was largely related to the pretreatment grade. Radiosurgery several years prior to surgical resection appears useful in treating unusually large and complex AVMs.

Adolescent↗

Heavy fragment production cross sections from 1.05 GeV/nucleon 56Fe in C, Al, Cu, Pb, and CH2 targets.

We have obtained charge-changing cross sections and partial cross sections for fragmentation of 1.05 GeV/nucleon Fe projectiles incident on H, C, Al, Cu, and Pb nuclei. The energy region covered by this experiment is critical for an understanding of galactic cosmic ray propagation and space radiation biophysics. Surviving primary beam particles and fragments with charges from 12 to 25 produced within a forward cone of half-angle 61 mrad were detected using a silicon detector telescope to identify their charge and the cross sections were calculated after correction of the measured yields for finite target thickness effects. The cross sections are compared to model calculations and to previous measurements. Cross sections for the production of fragments with even-numbered nuclear charges are seen to be enhanced in almost all cases.

Aluminum↗

Computed tomography slice-by-slice target-volume delineation for stereotactic proton irradiation of large intracranial arteriovenous malformations: an iterative approach using angiography, computed tomography, and magnetic resonance imaging.

PURPOSE: Target-volume delineation for stereotactic irradiation is problematic for large and irregularly shaped arteriovenous malformations (AVMs). The purpose of this report is to quantify modifications in the target volume that result from iterative treatment planning that incorporates multimodality imaging data. METHODS AND MATERIALS: Stereotactic neuroimaging procedures were performed for 20 consecutive patients with AVM volumes > 10 cm3. Angiographically defined extrema were transformed into computed tomography (CT) space. The resulting target contours were then modified by a multidisciplinary treatment planning team after iterative review of angiographic, CT, and magnetic resonance imaging (MRI) data. Volumes of interest and dose-volume histograms for proton irradiation were calculated before and after iterative target delineation. RESULTS: Initial (angiographically defined) target volumes ranged from 15.3 to 96.1 cm3 (mean, 43.6 cm3). Final (iteratively defined) target volumes ranged from 10.7 to 114.0 cm3 (mean, 38.4 cm3). The volume of presumed normal tissue excluded by iterative planning ranged from 2.6 to 47.0 cm3 (mean, 15.5 cm3). Initially untargeted AVM, most commonly obscured by embolization material, was identified in all cases (range, 0.3 to 57.8 cm3; mean, 10.3 cm3). Corresponding dose-volume histograms demonstrated marked differences regarding lesion coverage and sparing of normal tissue structures. CONCLUSIONS: Iterative target-volume delineation resulted in significant modifications from initial, angiographically defined target volumes. Substantial amounts of apparently normal tissue were excluded from the final target, and additional abnormal vascular structures were identified for incorporation. We conclude that an iterative multimodality approach to target-volume delineation may improve the overall results for stereotactic irradiation of large and complex AVMs.

Humans↗

Depressed mothers: they don't always look as bad as they feel.

OBJECTIVE: The relationship of maternal depression to self-report and observational data was investigated in a sample of depressed (n = 30) and nondepressed women (n = 32) and their 3-year-old children. Depression characteristics (diagnostic subtype/remission status) were related to maternal self-report and mother-child interactions. METHOD: Mothers completed standardized questionnaires and the dyad was observed in the laboratory. Observations were rated for maternal behavior and child attachment. RESULTS: There were no differences between depressed and nondepressed groups on observational measures; depressed mothers' self-report was consistently more negative. Within the depressed group, women with more severe/chronic depression showed behavioral differences but were no different from less depressed women on self-report measures. Women in remission improved for self-report, but not for observational data. CONCLUSIONS: The consequences of maternal depression vary depending on type of depression, severity, chronicity, current mood status, and on how the impact of depression is measured.

Adult↗

A modular solid state detector for measuring high energy heavy ion fragmentation near the beam axis.

A multi-element solid state detector has been designed to measure fluences of fragments produced near the beam axis by high energy heavy ion beams in thick targets. The detector is compact and modular, so as to be readily reconfigured according to the range of fragment charges and energies to be measured. Preamplifier gain settings and detector calibrations are adjustable remotely under computer control. We describe the central detector, its associated detectors and electronics, triggering scheme, data acquisition and particle identification techniques, illustrated by data taken with 600 MeV/u 56Fe beams and thick polyethylene targets at the LBL Bevalac. The applications of this work to space radiation protection are discussed.

Algorithms↗

High-dose single-fraction brain irradiation: MRI, cerebral blood flow, electrophysiological, and histological studies.

Radiation-induced alterations in cerebrovascular and metabolic function form the basis for the radiosurgical treatment of selected intracranial vascular malformations and tumors in human patients. However, the underlying mechanisms, temporal progression, and modifying factors involved in the radiosurgical obliteration of these intracranial lesions as well as the risks of delayed radiation injury to surrounding normal brain remain poorly understood. In this report, the rabbit brain was used as an animal model to examine the effects of high-dose single-fraction X-irradiation on magnetic resonance imaging (MRI) appearance, neurophysiologic function, and histological integrity. At approximately 10 weeks following left-hemisphere irradiation with 60 Gy (225 kVp) X rays, MRI studies showed radiation-induced changes including blood-brain barrier (BBB) perturbations in the white matter regions and the hippocampus. Significant reductions in regional cerebral blood flow (rCBF) ratios were found in the hippocampus and certain regions of the cortex in irradiated animals. However, no changes in somatosensory evoked potentials (SEP) were observed. Histological studies demonstrated telangiectatic vessels, spreading edema in the white matter, and focal regions of necrosis and hemorrhage in the irradiated cortices and hippocampi. These results demonstrate that the irradiated rabbit brain may be used as an experimental model to correlate the spatiotemporal pattern of functional changes with radiologic and histological changes in delayed radiation injury.

Animals↗

Early melanoma.

Explore the source record for details and available documents.

Epidermis↗

Radiation physics for particle beam radiosurgery.

For the particles and energies considered suitable for radiosurgery, with increasing particle charge, the Bragg peak height reaches a maximum with helium and then decreases, the Bragg peak width narrows, the distal fall-off steepens, and the exit dose increases (Table 1). The helium-ion beam is superior to a proton beam because of the higher peak-plateau ratio, more rapid dose fall-off, and smaller beam deflection, and it suffers only in the modest exit dose. Comparison of the therapeutically useful parameters of these beams is complicated by the change in beam quality (LET) with depth. Considerations of RBE values, which change with the ion species and with depth of penetration, may alter the relative rankings based on one or more of these beam characterization values. For all these beams, the RBE increases with increasing LET. The effect for protons is small and occurs just at the end of range of the particles. Effective isodose distributions based on modeled beams have been reported for helium, carbon, and neon ions. These distributions include the effects of a varying RBE with changes in the beam quality (as measured by a dose-weighted LET) and the change in dose fraction size with depth (the dose per fraction is a function of the depth of penetration). These calculations suggest that the optimal charged-particle beam for radiosurgery might be carbon. Heavy charged-particle beams can produce dose distributions superior to those obtainable with photon or electron beams. In clinical trials, these dose distributions have proved to be useful for the treatment of human diseases, including neoplasia and life-threatening intracranial disorders.(ABSTRACT TRUNCATED AT 250 WORDS)

Brain Neoplasms↗

Charged-particle radiosurgery for intracranial vascular malformations.

Heavy charged-particle radiation has unique physical characteristics that offer several advantages over photons and protons for stereotactic radiosurgery of intracranial AVMs. These include improved dose distributions with depth in tissue, small angle of lateral scattering, and sharp distal fall-off of dose in the Bragg ionization peak. Under multi-institutionally approved clinical trials, we have used stereotactic helium-ion Bragg peak radiosurgery to treat approximately 400 patients with symptomatic, surgically inaccessible vascular malformations at the UCB-LBL 184-in synchrocyclotron and bevatron. Treatment planning for stereotactic heavy charged-particle radiosurgery for intracranial vascular disorders integrates anatomic and physical information from the stereotactic cerebral angiogram and stereotactic CT and MR imaging scans for each patient, using computerized treatment-planning calculations for optimal isodose contour distribution. The shape of an intracranial AVM is associated strongly with its treatability and potential clinical outcome. In this respect, heavy charged-particle radiosurgery has distinct advantages over other radiosurgical methods; the unique physical properties allow the shaping of individual beams to encompass the contours of large and complexly shaped AVMs, while sparing important adjacent neural structures. We have had a long-term dose-searching clinical protocol in collaboration with SUMC and UCSF and have followed up over 300 patients for more than 2 years. Initially, treatment doses ranged from 45 GyE to 35 GyE. Currently, total doses up to 25 GyE are delivered to treatment volumes ranging from 0.1 cm3 to 70 cm3. This represents a relatively homogeneous dose distribution, with the 90% isodose surface contoured to the periphery of the lesion; there is considerable protection of normal adjacent brain tissues, and most of the brain receives no radiation exposure. Dose selection depends on the volume, shape, and location of the AVM and several other factors, including the volume of normal brain that must be traversed by the plateau portion of the charged-particle beam. The first 230 patients have been evaluated clinically to the end of 1989. Using the clinical grading of Drake, about 90% of the patients had an excellent or good neurologic grade, about 5% had a poor grade, and about 5% had progression of disease and died, or died as a result of unrelated intercurrent illness. Neuroradiologic follow-up to the end of 1989 indicated the following rates of complete angiographic obliteration 3 years after treatment: 90% to 95% for AVM treatment volumes less than 4 cm3, 90% to 95% for volumes 4 to 14 cm3, and 60% to 70% for volumes greater than 14 cm3.(ABSTRACT TRUNCATED AT 400 WORDS)

Adult↗

MRI and PET of delayed heavy-ion radiation injury in the rabbit brain.

Magnetic resonance imaging (MRI) and positron emission tomography (PET) techniques were used to obtain in vivo scans of delayed (30 GyE helium ion, 230 MeV/u) radiation injury in rabbit brain. T2-weighted (T2W) MRI scans demonstrated alterations that were restricted primarily to the white matter tracts and the deep perithalamic and thalamic regions. Quantitative measurements of T2 and T1 values demonstrated wide variations in absolute values. However, paired comparisons in hemibrain-irradiated rabbits revealed significant increases in T2 (p less than 0.001) and T1 (p less than 0.01) in irradiated versus unirradiated brain. Gadolinium DTPA (GdDTPA) enhanced MRI and 82Rubidium (82Rb) PET detected focal regions of blood-brain barrier (BBB) disruption restricted to the deep white matter and thalamic regions. Sequential GdDTPA enhanced MRI scans showed the spreading of the tracer from the initial site of contrast enhancement. 18Fluorodeoxyglucose (18FDG) PET studies demonstrated the markedly depressed metabolic profiles of irradiated brain. Histological findings of tissue edema and necrosis correlated well with the in vivo imaging abnormalities. These initial studies demonstrate that the irradiated rabbit brain is a suitable animal model for examining the delayed effects of radiation injury in the brain.

Animals↗

Image correlation of MRI and CT in treatment planning for radiosurgery of intracranial vascular malformations.

Magnetic resonance imaging (MRI) has been incorporated with stereotactic cerebral angiography and computed tomography (CT) in the treatment planning process of heavy ion radiosurgery of intracranial arteriovenous malformations (AVM's). Correlation of the images of the AVM and normal tissue on each of these neuroradiological imaging modalities is achieved by means of fiducial markers. The computerized transfer of angiographic information to the CT images regarding the size, shape, and location of the abnormal vasculature has been described in an earlier report. A separate computer program calculates a fit between individual fiducial markers on the CT and MR images that enables the transfer of contours between the two imaging modalities. The MR images aid in the determination of the 3-dimensional shape of the AVM, adding to the information derived from the two angiographic projections. Currently, MRI cannot replace cerebral angiography in delineating the entire arterial phase of the AVM. Magnetic resonance imaging is invaluable in the treatment planning of angiographically-occult AVM's, determining the location, size, and shape of the volume to be treated. Correlation of the CT and MRI images allows for the transfer of CT-calculated isodose contours to the MRI images to aid in the determination of optimal treatment plans.

Adolescent↗