Management of Budd-Chiari syndrome by hepatic vein stenting after extended right hepatectomy.

Massive splenomegaly and ascites production with hypoproteinemia and hypocoagulability was observed in a 15-year-old boy after extended right hepatectomy for hepatocellular carcinoma (HCC). Angiography disclosed a kinking of the left hepatic vein immediately before the junction with the inferior vena cava. Ascites disappeared completely, and laboratory values normalized after placement of a 3-cm long balloon expandable stent. The current case shows that Budd-Chiari syndrome caused by hepatic outflow obstruction after major hepatic surgery can be managed effectively by percutaneous stent placement.

Adolescent↗

[The value of different spiral CT phases in the detection of liver metastases].

PURPOSE: To assess the value of the non-contrast phase (NCP), hepatic-arterial phase (HAP) and portal-venous phases (PVP) for the detection of liver metastases by spiral CT. METHODS: In order to detect liver metastases, 119 patients (58 women, 61 men; mean age: 62 years) underwent triphasic spiral CT (8 mm collimation, 12 mm table increment/rotation, 7 mm reconstruction increment). NCP, HAP (20 s delay) and PVP (70 s delay) scans were acquired (contrast medium injection rate: 4 ml/s). CT analysis comprised independent evaluation of the three scan series for detection and conspicuity of liver metastases (conspicuity score: 0 = not visible, 1 = barely visible, 2 = clearly visible, 3 = distinctly visible). RESULTS: In 83 of the 119 patients, 478 liver metastases were detected (110 hypervascular and 368 hypovascular lesions). 285 (60 %) metastases were detected on NCP scans. Significantly more lesions were seen on HAP (n = 375, 78 %) and on PVP (n = 428, 90 %). No lesion was detected on NCP studies alone. For all detected metastases, mean conspicuity was 1.2 +/- 0.4 on NCP, 1.8 +/- 0.8 on HAP and 2.2 +/- 0.8 PVP. Hypervascular lesions were best seen on HAP with a conspicuity score of 2.0 +/- 0.8 versus 1.3 +/- 0.5 on NCP and 1.5 +/- 0.8 on PVP. Hypovascular lesions reached the highest conspicuity on PVP with 2.4 +/- 0.8 versus 1.2 +/- 0.4 on NCP and 1.7 +/- 0.7 on HAP. CONCLUSION: For detection of liver metastases with spiral CT, contrast series seem to be sufficient. For tumors likely to seed hypervascular metastases, HAP scans should be applied in addition to the PVP.

Adult↗

[Pelvic artery embolization in gynecological bleeding].

The most common reasons for gynecological bleeding are pregnancy-related disorders, fibroids of the uterus, and gynecological malignancies. Transarterial embolization is an effective treatment modality for gynecological bleeding regardless of its etiology. Depending on the underlying disease, a different technique of embolization is applied. In postpartal bleeding a temporary effect of embolization is desired, therefore gelatin sponge is used as embolizing agent. In fibroids and malignant tumors the effect should permanent, therefore PVA particles are used. Regardless the etiology, the technical and clinical success of transarterial embolization is at least 90 %. In nearly every patient a post-embolization syndrome can be observed, represented by local pain and fever. This post-embolization syndrome usually does not last longer than 3 days. If embolization is performed with meticulous attention to angiographic technique and handling of embolic material, ischemic damage of adjacent organs is rarely observed. Transarterial embolization should be an integrative modality in the treatment of gynecological bleeding.

Angiography↗

Complications in endoluminal repair of abdominal aortic aneurysms.

In this review the technical and systemic complications occurring during endoluminal repair of abdominal aortic aneurysms are summarized. According to the data in the literature the technical success-rate of the endoluminal procedure should be >90% and the overall complication-rate <10%. It should be differentiated between complications which have an adverse effect on the outcome of the procedure, and technical problems, which complicate the procedure but do not affect the outcome. The majority of the technical problems can be solved endoluminally. The 30-day mortality rate should be in the same range as elective open surgical repair. One major factor influencing the immediate results is the experience of the interventional team.

Aortic Aneurysm, Abdominal↗

Placement of Hemobahn stent-grafts in femoropopliteal arteries: early experience and midterm results in 18 patients.

PURPOSE: To determine the outcome of a new polytetrafluoroethylene (PTFE)-covered stent-graft in the treatment of occlusive lesions of the femoropopliteal arteries. MATERIALS AND METHODS: Eighteen patients with intermittent claudication (Fontaine stages IIb-IV; Rutherford classes I/2-III/5) and occlusive lesions of the superficial femoral and/or popliteal artery were treated with use of a new PTFE-covered stent-graft (Hemobahn). Indication for stent-graft insertion was an unsatisfactory result after balloon dilation. RESULTS: Successful stent-graft placement was achieved in 17 patients (94%). In one patient, additional insertion of a Palmaz stent was necessary because of a stent-graft wrinkle. Mean ankle-brachial index increased from 0.72 +/- 0.15 preoperatively to 0.94 +/- 0.17 postoperatively (P =.028). Fifteen patients (83%) experienced an initial improvement of at least one clinical stage. Primary patency was 61% +/- 11% at 3 months and 49% +/- 12% at 6 months. Stent-graft occlusion was observed in 13 patients (72%). In four patients, the stent-graft was reopened percutaneously by balloon angioplasty (n = 2) and/or rotational thrombectomy (n = 2). Therefore, the secondary patency rate was 67% +/- 11% at 3 months and 61% +/- 11% at 6 months. Patency rates proved to be significantly lower for stent-grafts longer than 10 cm (P =.03). Intimal hyperplasia at the proximal or distal end of the stent-graft was observed in seven patients (39%). Complications such as access site hematoma (n = 3), distal thromboembolism (n = 2), and abscess formation around the stent-graft (n = 1) were observed. CONCLUSION: Despite excellent initial angiographic results, the patency rate in lesions treated with the Hemobahn stent-graft in this small study was unsatisfactory. Use of stent-grafts longer than 10 cm and the occurrence of intimal hyperplasia proved to be major factors in the reduction of long-term patency rates.

Aged↗

Endovascular stent-graft repair of acute thoracic aortic dissection--early clinical experiences.

BACKGROUND: Standard treatment of acute thoracic aortic dissection type B is the medical therapy used for most patients, according to Stanford. Surgical therapy involves a high mortality rate and is reserved for patients with complicated dissections. We report from four patients with acute thoracic aortic dissection, treated endoluminally by stent-graft implantation. METHODS: Four patients with complicated acute thoracic aortic dissections type B were treated endoluminally by transfemoral stent-graft implantation. Preoperative evaluation was performed with spiral-computed tomography and calibrated aortography. The Talent stent-graft system (Metronic) was used in all patients. RESULTS: The primary entry tear could be sealed successfully and complete thrombosis of the false thoracic aortic lumen was obtained in all cases. In one patient, transposition of the left subclavian artery was performed, in two patients the stent-grafts had to be placed across the origin of the left subclavian artery. No severe intra- or postoperative complications occurred. CONCLUSION: Endoluminal treatment of acute thoracic aortic dissection seems to be a less invasive and effective therapy. Long-term results for this method are necessary.

Acute Disease↗

Intentional left subclavian artery occlusion by thoracic aortic stent-grafts without surgical transposition.

PURPOSE: To report the consequences of endoluminal deployment of stent-grafts in the thoracic aorta with intentional occlusion of the left subclavian artery. CASE REPORTS: Three patients with an aortic type-B dissection and 1 with a thoracic aneurysm were treated endoluminally with Talent stent-grafts implanted over the ostium of the left subclavian artery without prior surgical subclavian-carotid transposition. The primary intimal tears were sealed and the degenerative aneurysm excluded; blood pressure in the left arm was significantly diminished immediately after the stent-graft was released, but adequate collateral retrograde perfusion via the left vertebral artery was apparent in all patients. No neurological deficit and no symptoms of left arm ischemia were observed in a follow-up that ranged from 14 to 20 months. CONCLUSIONS: Our limited experience shows that occlusion of the left subclavian artery with a stent-graft is well tolerated. If ischemic symptoms occur, a transposition procedure can be performed on an elective basis.

Aged↗

[Transposition of the subclavian artery with endovascular stent graft implantation for therapy of acute type B aortic dissection].

We report about a patient with a thoracic aneurysm caused by an acute type-B dissection. Due to the concomitant affections the risk of surgery was distinctly increased, the reconstruction was performed endo vascular by stentgraft implantation (Talent, World Medical Systems, Sunrise FL) after transposition of the left subclavian artery to create a sufficient neck for the proximal stent placement. Endoluminal treatment seems to be a promising, less invasive alternative method in the treatment of acute aortic dissections.

Acute Disease↗

Endovascular stentgraft infection--a life-threatening complication.

The implantation of covered stents or stentgrafts has increased greatly in the last few years for the endovascular reconstruction of arterial aneurysms. We report of three patients experiencing severe septic complications after stentgraft implantation. Endovascular stentgraft infection is a serious complication with high morbidity and mortality. General antibiotic prophylaxis seems to be indicated when implanting stentgrafts.

Aged↗

[Treatment of malignant and benign biliary obstructions with metal stents].

The palliative treatment of malignant biliary tract obstructions using a metal stent is now an established procedure in clinical practice. An endoscopic, transpapillary approach is the first choice for implantation of the stent. If it is not possible to insert the stent in this way, which is often the case with high obstructions, a percutaneous approach is chosen. It appears to be beneficial to use a metal stent with a fine-meshed net such as, for example, the Wall stent. Metal stents have a higher patency rate than plastic stents so that the primary choice of a metal stent is justified. Coated stents have not yet shown any major advantages. In cases of stent occlusion, the coaxial implantation of a plastic stent seems to be the most efficient. In cases of benign biliary tract stenoses, a metal stent should only be implanted after a careful evaluation of all possible surgical modalities and exploitation of balloon dilatation and long-term splinting methods.

Aged↗

Cerebrospinal fluid drainage to reverse paraplegia after endovascular thoracic aortic aneurysm repair.

PURPOSE: To report a case of endovascular descending thoracic aortic aneurysm (TAA) repair in which delayed-onset paraplegia was reversed using cerebrospinal fluid (CSF) drainage. METHODS AND RESULTS: A 74-year-old patient with a 6.0-cm TAA underwent endovascular stent-graft repair that involved overlapping placement of 3 Talent devices to cover the 31-cm-long defect. Twelve hours later, a neurological deficit occurred manifesting as left leg paralysis with paresis on the right. After urgent intrathecal catheter placement and drainage of cerebrospinal fluid for 48 hours, the neurological deficit resolved. The patient's clinical condition was normal and endoluminal exclusion of the TAA remained secure at 8-month follow-up. CONCLUSIONS: This case demonstrates the potential therapeutic role for CSF drainage to reduce the complications of spinal cord injury after endovascular thoracic aneurysm repair.

Aged↗

Endoluminal treatment of infrarenal aortic aneurysms: clinical experience with the Talent stent-graft system.

PURPOSE: To evaluate the safety and efficacy of the Talent stent-graft (TSG) system in the endoluminal treatment of infrarenal abdominal aortic aneurysms (AAAs). PATIENTS AND METHODS: Endoluminal treatment of an AAA was attempted in 30 men with a mean age of 70.5 years (range, 51-83 years). Seven patients had AAAs suitable for treatment with a tube graft. In the other patients, treatment with a bifurcated TSG was planned. All procedures were performed as a combined surgical-radiologic procedure in an angiographic room. RESULTS: Primary technical success was achieved in 25 of 30 patients (83%). Technical failures were due to misplacement of the TSG (n = 2) with proximal leakage as a consequence, inability to gain access via the iliac arteries (n = 1), and a distal leakage (n = 2). Secondary interventions (n = 2) and spontaneous thrombosis of a distal leak (n = 1) increased the secondary technical success rate to 93% (28 of 30). Two procedures were converted to open surgery (conversion rate = 6%). One patient died during the first 30 days after uncomplicated stent-graft insertion because of myocardial infarction (30-day mortality = 5%). No complications occurred during a mean follow-up of 15.4 months (range, 6-19 months). The maximum diameter of the AAA decreased in eight patients and remained unchanged in the remaining patients. No increase in diameter was observed. No late endoleak or migration of the TSG was observed. CONCLUSION: The TSG-system revealed satisfactory initial and early follow-up results. Treatment of AAAs with this stent-graft system is feasible. The technical success rate in carefully selected patients should be 90% or more. However, long-term observations are necessary to determine if the encouraging early results of this type of therapy can be preserved during long-term follow-up.

Aged↗

Aortoduodenal fistula: a late complication of intraluminal exclusion of an infrarenal aortic aneurysm.

During recent years, considerable clinical experience has been gained with endoluminal stent-graft procedures. Several studies have shown promising results up to a period of 4.5 years. However, long-term follow-up studies are still limited. Late endoleaks caused by stent-graft migration, disconnection of single components in modular stent-grafts, and limb thrombosis have been observed as long-term complications. We report a case in which a migrated and kinked bifurcated stent-graft caused an aortoduodenal fistula 20 months after stent-graft insertion. To our knowledge, such a complication has not been reported before.

Aorta, Abdominal↗

[Endoluminal therapy of infrarenal aortic aneurysms with the Talent system--initial experiences with a new endoprosthesis].

PURPOSE: To report the early clinical experience with the Talent stent-graft system in the treatment of infrarenal aortic aneurysms. MATERIALS AND METHODS: The study group comprised 15 males aged from 51-79 years. A bifurcated Talent stent-graft was implanted in 9 patients with type B or C aneurysms, a tube graft in 6 patients with a type A aneurysm. The stent-grafts were introduced via a surgical femoral cut-down, for a bifurcated graft a bilateral surgical access was needed. All procedures were performed as teamwork by radiologists and vascular surgeons under general anaesthesia in the angiography suite. RESULTS: Primary and secondary technical successes were 80 and 86%, respectively. Technical failures were due to access site problems (n = 1; elective open repair), malpositioning of the prosthesis (n = 1; immediate conversion to open surgery), and primary distal leakage (n = 1; elective occlusion by means of distal stent-graft extension). One patient died 15 days after an uneventful stent-graft insertion (30-day mortality 6%). No complications were observed during a mean follow-up period of 7.8 months. The aneurysmal diameter decreased in 6 patients and remained unchanged in the others. CONCLUSIONS: The Talent system revealed satisfactory early results which are comparable to competitive stent-graft systems. An advantage of this stent-graft device is the availability in a wide range of dimensions. A major disadvantage is the large introducer system (french size 22-27).

Aged↗

Treatment of malignant biliary obstruction with polyurethane-covered Wallstents.

OBJECTIVE: This study was undertaken to determine the safety, efficacy, and performance of polyurethane-covered Wallstents in the treatment of malignant biliary obstruction. SUBJECTS AND METHODS: This pilot study included 30 patients with malignant biliary obstruction. Palliative decompression of the obstructed bile duct was attempted with a polyurethane-covered Wallstent that is a prototype. Patients with hilar obstructions were excluded. All stents were inserted percutaneously. Kaplan-Meier analysis was used to determine stent patency. RESULTS: Effective biliary decompression was achieved in all patients initially. No acute stent-related complications occurred. The 30-day mortality rate was 20%. During follow-up, 11 stent occlusions occurred; therefore, the occlusion rate was 37%. The patency rates after 1, 3, 6, and 12 months were 96%, 69%, 47%, and 31%, respectively. Tumor growth through the stent covering that was proven both histologically and by biopsy observed in two patients, causing stent occlusion in one of them. Other reasons for stent occlusion were distal tumor ingrowth (n = 1) and biopsy-proven granulation tissue inside the stent (n = 2). Otherwise, the reasons for stent occlusion remained unclear. CONCLUSION: This prototype of a covered stent did not provide better results than did conventional uncovered stents in patients with malignant biliary obstruction. The covering did not effectively prevent tumor ingrowth in at least two patients. The stent also seems prone to premature occlusion.

Aged↗

Value of echo-enhanced Doppler sonography in evaluation of transjugular intrahepatic portosystemic shunts.

OBJECTIVE: The value of echo-enhanced color and power Doppler sonography in the evaluation of transjugular intrahepatic portosystemic shunts (TIPS) was assessed and compared with that of unenhanced Doppler sonography and portal angiography. SUBJECTS AND METHODS: In a prospective randomized trial, 31 shunts in 30 patients underwent unenhanced conventional color and power Doppler sonography and portal venography including pressure measurements. The patients were allocated to either echo-enhanced conventional color Doppler sonography or echo-enhanced power Doppler sonography. For echo enhancement, a galactose-based suspension was administered IV. Shunt stenoses, if present, were quantified by percentage of stenosis and correlated with angiography, which was the gold standard. The diagnostic confidence of unenhanced and echo-enhanced Doppler sonography was assessed using a visual analog scale. RESULTS: In the diagnosis of shunt occlusion, echo-enhanced Doppler sonography yielded a sensitivity and a specificity of 100% and 100%, respectively, compared with 100% and 89%, respectively, for unenhanced Doppler sonography. Our evaluation of hemodynamically significant stenoses (portosystemic gradient > or = 15 mm Hg) found echo-enhanced Doppler sonography to be superior to unenhanced Doppler sonography (sensitivity and specificity of 82% and 83%, respectively, compared with 64% and 80%, respectively). In the detection of a shunt stenosis based on morphologic criteria only, echo-enhanced Doppler sonography yielded a sensitivity and a specificity of 78% and 100%, respectively, compared with 47% and 50%, respectively, for unenhanced Doppler sonography. Power Doppler imaging did not improve diagnostic accuracy but did increase diagnostic confidence for unenhanced Doppler sonography compared with conventional color Doppler sonography. The diagnostic confidence for sonographic evaluation of TIPS was significantly (p < .001) increased and the variability of hemodynamic measurements was markedly decreased with echo-enhanced sonography. CONCLUSION: Echo-enhanced Doppler sonography provides images of TIPS like those of angiography and allows morphologic assessment of the shunts, complementary to the essential pulsed Doppler waveform analysis that would be performed in a more guided manner. Also, echo-enhanced Doppler sonography significantly increases the sensitivity and specificity in the diagnosis of shunt dysfunction. The high diagnostic confidence and the diminished variability of spectral Doppler measurements may improve acceptance of sonographic evaluation of TIPS. Echo-enhanced Doppler sonography is safe and effective and may reduce the instances in which TIPS sonographic surveillance is nondiagnostic, in which case angiographic assessment is required.

Adult↗