Assessment of LV systolic function in atrial fibrillation using an index of preceding cardiac cycles.

The clinical assessment of left ventricular (LV) systolic function during atrial fibrillation (AF) is unreliable and difficult because of beat-to-beat variability. We evaluated an index for the estimation of LV systolic function in AF that is based on the relationship between the preceding (R-R1) and prepreceding (R-R2) R-R intervals. LV Doppler stroke volume (SV), ejection fraction (EF), peak aortic flow rate (AoF) and the maximum value of the first derivative of the LV pressure curve (dP/dt(max)) were evaluated in 13 healthy open-chest dogs during triggered AF. All parameters showed a significantly strong positive linear relationship with the ratio of R-R1/R-R2 (r = 0.65, 0.74, 0.75, and 0.70 for SV, EF, AoF, and dP/dt(max), respectively). The calculated value of LV systolic parameters at R-R1/R-R2 = 1 in the linear regression line showed a good relationship and an agreement with the measured average value of the parameter over all cardiac cycles (SV, 12.1 vs. 12.8 ml; EF, 49.6 vs. 51.2%; AoF, 1.37 vs. 1.48 l/min; and dP/dt(max), 2,323 vs. 2,454 mmHg/s). Using the LV systolic parameters estimated at R-R1/R-R2 = 1 in the linear regression line allows the LV contractile function to be accurately and reproducibly evaluated during AF and obviates the less-reliable process of averaging multiple cardiac cycles.

Animals↗

New approach to biphasic waveforms for internal defibrillation: fully discharging capacitors.

INTRODUCTION: The use of two independent, fully discharging capacitors for each phase of a biphasic defibrillation waveform may lead to the design of a simpler, smaller, internal defibrillator. The goal of this study was to determine the optimal combination of capacitor sizes for such a waveform. METHODS AND RESULTS: Eight full-discharge (95/95% tilt), biphasic waveforms produced by several combinations of phase-1 capacitors (30, 60, and 90 microF) and phase-2 capacitors (1/3, 2/3, and 1.0 times the phase-1 capacitor) were tested and compared to a single-capacitor waveform (120 microF, 65/65% tilt) in a pig ventricular fibrillation model (n = 12, 23+/-2 kg). In the full-discharge waveforms, phase-2 peak voltage was equal to phase-1 peak voltage. Shocks were delivered between a right ventricular lead and a left pectoral can electrode. E50s and V50s were determined using a ten-step Bayesian process. Full-discharge waveforms with phase-2 capacitors of < or =40 microF had the same E50 (6.7+/-1.7 J to 7.3+/-3.9 J) as the single-capacitor truncated waveform (7.3+/-3.7 J), whereas waveforms with phase-2 capacitors of > or =60 microF had an extremely high E50 (14.5+/-10.8 J or greater, P < 0.05). Moreover, of the former set of energy-efficient waveforms, those with phase-1 capacitors of > or =60 microF additionally exhibited V50s that were equivalent to the V50 of the single-capacitor waveform (344+/-65 V to 407+/-50 V vs 339+/-83 V). CONCLUSION: Defibrillation efficacy can be maintained in a full-discharge, two-capacitor waveform with the proper choice of capacitors.

Animals↗

Virtual electrode-induced reexcitation: A mechanism of defibrillation.

Mechanisms of defibrillation remain poorly understood. Defibrillation success depends on the elimination of fibrillation without shock-induced arrhythmogenesis. We optically mapped selected epicardial regions of rabbit hearts (n=20) during shocks applied with the use of implantable defibrillator electrodes during the refractory period. Monophasic shocks resulted in virtual electrode polarization (VEP). Positive values of VEP resulted in a prolongation of the action potential duration, whereas negative polarization shortened the action potential duration, resulting in partial or complete recovery of the excitability. After a shock, new propagated wavefronts emerged at the boundary between the 2 regions and reexcited negatively polarized regions. Conduction velocity and maximum action potential upstroke rate of rise dV/dt (max) of shock-induced activation depended on the transmembrane potential at the end of the shock. Linear regression analysis showed that dV/dt(max) of postshock activation reached 50% of that of normal action potential at a V(m) value of -56.7+/-0.6 mV postshock voltage (n=9257). Less negative potentials resulted in slow conduction and blocks, whereas more negative potentials resulted in faster conduction. Although wavebreaks were produced in either condition, they degenerated into arrhythmias only when conduction was slow. Shock-induced VEP is essential in extinguishing fibrillation but can reinduce arrhythmias by producing excitable gaps. Reexcitation of these gaps through progressive increase in shock strength may provide the basis for the lower and upper limits of vulnerability. The former may correspond to the origination of slow wavefronts of reexcitation and phase singularities. The latter corresponds to fast conduction during which wavebreaks no longer produce sustained arrhythmias.

Animals↗

Fully discharging phases. A new approach to biphasic waveforms for external defibrillation.

BACKGROUND: Phase-2 voltage and maximum pulse width are dependent on phase-1 pulse characteristics in a single-capacitor biphasic waveform. The use of 2 separate output capacitors avoids these limitations and may allow waveforms with lower defibrillation thresholds. A previous report also suggested that the optimal tilt may be >70%. This study was designed to determine an optimal biphasic waveform by use of a combination of 2 separate and fully (95% tilt) discharging capacitors. METHODS AND RESULTS: We performed 2 external defibrillation studies in a pig ventricular fibrillation model. In group 1, 9 waveforms from a combination of 3 phase-1 capacitor values (30, 60, and 120 microF) and 3 phase-2 capacitor values (0=monophasic, 1/3, and 1.0 times the phase-1 capacitor) were tested. Biphasic waveforms with phase-2 capacitors of 1/3 times that of phase 1 provided the highest defibrillation efficacy (stored energy and voltage) compared with corresponding monophasic and biphasic waveforms with the same capacitors in both phases except for waveforms with a 30-microF phase-1 capacitor. In group 2, 10 biphasic waveforms from a combination of 2 phase-1 capacitor values (30 and 60 microF) and 5 phase-2 capacitor values (10, 20, 30, 40, and 50 microF) were tested. In this range, phase-2 capacitor size was more critical for the 30-microF phase-1 than for the 60-microF phase-1 capacitor. The optimal combinations of fully discharging capacitors for defibrillation were 60/20 and 60/30 microF. Conclusions-Phase-2 capacitor size plays an important role in reducing defibrillation energy in biphasic waveforms when 2 separate and fully discharging capacitors are used.

Animals↗

Autonomic modification of the atrioventricular node during atrial fibrillation: role in the slowing of ventricular rate.

BACKGROUND: Postganglionic vagal stimulation (PGVS) by short bursts of subthreshold current evokes release of acetylcholine from myocardial nerve terminals. PGVS applied to the atrioventricular node (AVN) slows nodal conduction. However, little is known about the ability of PGVS to control ventricular rate (VR) during atrial fibrillation (AF). METHODS AND RESULTS: To quantify the effects and establish the mechanism of PGVS on the AVN, AF was simulated by random high right atrial pacing in 11 atrial-AVN rabbit heart preparations. Microelectrode recordings of cellular action potentials (APs) were obtained from different AVN regions. Five intensities and 5 modes of PGVS delivery were evaluated. PGVS resulted in cellular hyperpolarization, along with depressed and highly heterogeneous intranodal conduction. Compact nodal AP exhibited decremental amplitude and dV/dt and multiple-hump components, and at high PGVS intensities, a high degree of concealed conduction resulted in a dramatic slowing of the VR. Progressive increase of PGVS intensity and/or rate of delivery showed a significant logarithmic correlation with a decrease in VR (P<0.001). Strong PGVS reduced the mean VR from 234 to 92 bpm (P<0.001). The PGVS effects on the cellular responses and VR during AF were fully reproduced in a model of direct acetylcholine injection into the compact AVN via micropipette. CONCLUSIONS: These studies confirmed that PGVS applied during AF could produce substantial VR slowing because of acetylcholine-induced depression of conduction in the AVN.

Animals↗

Atrioventricular nodal conduction during atrial fibrillation: role of atrial input modification.

BACKGROUND: Posteroseptal ablation of the atrioventricular node (AVN) has been proposed as a means to slow the ventricular rate during atrial fibrillation (AF). The suggested mechanism is elimination of the AVN "slow pathway." On the basis of the unpredictable success of the procedure, we hypothesize that, in fact, the slow pathway is preserved. Therefore, the slowing of the ventricular rate results from reduced bombardment of the AVN. METHODS AND RESULTS: In 8 rabbit heart atrial-AVN preparations, cooling of the posterior and/or the anterior AVN approaches revealed nonspecific effects on the slow and fast pathway portions of the AVN conduction curve. In 13 other preparations, simulated AF during posterior cooling (n=6) prolonged the His-His (H-H) intervals but did not reveal specific slow pathway injury. In the remaining 7 preparations, AF was applied before and after posteroseptal surgical cuts. During AF with posterior origin, the cuts resulted in longer mean H-H along with slowing of the AVN bombardment rate. However, there was no change in the minimum observed H-H, suggesting an intact slow pathway. During AF with anterior origin, the mean and the shortest H-H remained unchanged before and after the cuts in all preparations. This was associated with the maintenance of high-rate AVN bombardment. CONCLUSIONS: Posteroseptal ablation does not eliminate the slow pathway. Ventricular rate slowing can be obtained if the ablation procedure results in a posteroanterior intra-atrial block leading to a reduction of the rate of AV nodal bombardment.

Animals↗

Higher energy synchronized external direct current cardioversion for refractory atrial fibrillation.

OBJECTIVES: We sought to evaluate the safety and efficacy of higher energy synchronized cardioversion in patients with atrial fibrillation refractory to standard energy direct current (DC) cardioversion. BACKGROUND: Standard external electrical cardioversion fails to restore sinus rhythm in 5% to 30% of patients with atrial fibrillation. METHODS: Patients with atrial fibrillation who failed to achieve sinus rhythm after at least two attempts at standard external cardioversion with 360 J were included in the study. Two external defibrillators, each connected to its own pair of R-2 patches in the anteroposterior position, were used to deliver a synchronized total of 720 J. RESULTS: Fifty-five patients underwent cardioversion with 720 J. Mean weight was 117 +/- 23 kg (body mass index 48.3 +/- 4.1 kg/m2). Structural heart disease was present in 76% of patients. Mean left ventricular ejection fraction was 45 +/- 12%. Atrial fibrillation was present for over three months in 55% of the patients. Sinus rhythm was achieved in 46 (84%) of the 55 patients. No major complications were observed. No patient developed hemodynamic compromise and no documented cerebrovascular accident occurred within one month after cardioversion. Of the 46 successful cardioversions, 18 patients (39%) remained in sinus rhythm over a mean follow-up of 2.1 months. CONCLUSIONS: External higher energy cardioversion is effective in restoring sinus rhythm in patients with atrial fibrillation refractory to standard energy DC cardioversion. This method is safe and does not result in clinical evidence of myocardial impairment. It may be a useful alternative to internal cardioversion because it could be done within the same setting of the failed standard cardioversion and obviates the need to withhold protective anticoagulation for internal cardioversion.

Adult↗

External exponential biphasic versus monophasic shock waveform: efficacy in ventricular fibrillation of longer duration.

Ventricular fibrillation (VF) duration may be a factor in determining the defibrillation energy for successful defibrillation. Exponential biphasic waveforms have been shown to defibrillate with less energy than do monophasic waveforms when used for external defibrillation. However, it is unknown whether this advantage persists with longer VF duration. We tested the hypothesis that exponential biphasic waveforms have lower defibrillation energy as compared to exponential monophasic waveforms even with longer VF duration up to 1 minute. In a swine model of external defibrillation (n = 12, 35 +/- 6 kg), we determined the stored energy at 50% defibrillation success (E50) after both 10 seconds and 1 minute of VF duration. A single exponential monophasic (M) and two exponential biphasic (B1 and B2) waveforms were tested with the following characteristics: M (60 microF, 70% tilt), B1 (60/60 microF, 70% tilt/3 ms pulse width), and B2 (60/20 microF, 70% tilt/3 ms pulse width) where the ratio of the phase 2 leading edge voltage to that of phase 1 was 0.5 for B1 and 1.0 for B2. E50 was measured by a Bayesian technique with a total often defibrillation shocks in each waveform and VF duration randomly. The E50 (J) for M, B1, and B2 were 131 +/- 41, 57 +/- 18,* and 60 +/- 26* with 10 seconds of VF duration, respectively, and 114 +/- 62, 77 +/- 45,* and 72 +/- 53* with 1 minute of VF duration, respectively (*P < 0.05 vs M). There was no significant difference in the E50 between 10 seconds and 1 minute of VF durations for each waveform. We conclude that (1) the E50 does not significantly increase with lengthening VF durations up to 1 minute regardless of the shock waveform, and (2) external exponential biphasic shocks are more effective than monophasic waveforms even with longer VF durations.

Analysis of Variance↗

Effects of extracorporeal shock wave lithotripsy on tiered therapy implantable cardioverter defibrillators.

The effects of extracorporeal shock wave lithotripsy (ESWL) were tested on four advanced generation implantable cardioverter-defibrillators (ICDs) in vitro and in vivo in two patients. During in vitro testing, advancement of nonsustained episode counters occurred in one device, and a set screw and power source cell loosened in another, which was connected to an external power source. No arrhythmias occurred during in vivo procedures, but programmed parameters were reset and elective replacement indicated after one procedure. ESWL can be performed safely in selected patients with ICDs, but testing should be performed afterwards to confirm satisfactory function and component continuity.

Defibrillators, Implantable↗

Biventricular shocking leads improve defibrillation efficacy.

INTRODUCTION: A single lead active can configuration has been widely used in patients with life-threatening ventricular arrhythmias. Occasionally, however, such a defibrillation lead configuration may not achieve adequate defibrillation threshold (DFT). The purpose of this study was to determine whether addition of a left ventricular (LV) lead can improve defibrillation efficacy. METHODS AND RESULTS: Three transvenous defibrillation leads (8.3-French with a 5-cm long unipolar coil) were placed in the right ventricle (RV), LV, and superior vena cava (SVC), along with an active can (92 cm2) in the left subpectoral area. The DFT stored energy of seven combinations of these defibrillation leads were compared in a pig ventricular fibrillation model using a biphasic defibrillation waveform (125 microF, 6.5/3.5 msec). A biventricular leads active can configuration in which the RV and LV leads were of the same polarity reduced the DFT stored energy by approximately 35% when compared to a single RV lead active can configuration (9.6 +/- 3.0 J vs 15.0 +/- 7.2 J, respectively, P = 0.02). Moreover, adding a SVC lead further reduced the DFT energy (8.4 +/- 3.3 J). CONCLUSION: A biventricular leads active can configuration can significantly improve defibrillation efficacy as compared to a single lead active can configuration. In such a defibrillation lead configuration, the polarity of RV and LV leads should be the same.

Animals↗

Optimal small-capacitor biphasic waveform for external defibrillation: influence of phase-1 tilt and phase-2 voltage.

BACKGROUND: Biphasic waveforms have been reported to be more efficacious than monophasic waveforms for external defibrillation. This study examined the optimal phase-1 tilts and phase-2 leading-edge voltages with small capacitors (60 and 20 microF) for external defibrillation. We also assessed the ability of the "charge-burping" model to predict the optimal waveforms. METHODS AND RESULTS: Two groups of studies were performed. In group 1, 9 biphasic waveforms from a combination of 3 phase-1 tilt values (30%, 50%, and 70%) and 3 phase-2 leading-edge voltage values (0.5, 1.0, and 1.5 times the phase-1 leading-edge voltage, V1) were tested. Phase-2 pulse width was held constant at 3 ms in all waveforms. Two separate 60- microF capacitors were used in each phase. The energy value that would produce a 50% likelihood of successful defibrillation (E50) decreased with increasing phase-1 tilt and increased with increasing phase-2 leading-edge voltage except for the 30% phase-1 tilt waveforms. In group 2, 9 waveforms were identical to the waveforms in group 1, except for a 20- microF capacitor for phase 2. E50 decreased with increasing phase-1 tilt. Phase-2 leading-edge voltage of 1.0 to 1.5 V1 appeared to minimize E50 for phase-1 tilt of 50% and 70% but worsened E50 for phase-1 tilt of 30%. There was a significant correlation between E50 and residual membrane voltage at the end of phase 2, as calculated by the charge-burping model in both groups (group 1, R2=0.47, P<0.001; group 2, R2=0.42, P<0.001). CONCLUSIONS: The waveforms with 70% phase-1 tilt were more efficacious than those with 30% and 50%. The relationship of phase-2 leading-edge voltage to defibrillation efficacy depended on phase-2 capacitance. The charge-burping model predicted the optimal external biphasic waveform.

Animals↗

Effects of respiration phase on ventricular defibrillation threshold in a hot can electrode system.

The impedance of defibrillation pathways is an important determinant of ventricular defibrillation efficacy. The hypothesis in this study was that the respiration phase (end-inspiration versus end-expiration) may alter impedance and/or defibrillation efficacy in a "hot can" electrode system. Defibrillation threshold (DFT) parameters were evaluated at end-expiration and at end-inspiration phases in random order by a biphasic waveform in ten anesthetized pigs (body weight: 19.1 +/- 2.4 kg; heart weight: 97 +/- 10 g). Pigs were intubated with a cuffed endotracheal tube and ventilated through a Drager SAV respirator with tidal volume of 400-500 mL. A transvenous defibrillation lead (6 cm long, 6.5 Fr) was inserted into the right ventricular apex. A titanium can electrode (92-cm2 surface area) was placed in the left pectoral area. The right ventricular lead was the anode for the first phase and the cathode for the second phase. The DFT was determined by a "down-up down-up" protocol. Statistical analysis was performed with a Wilcoxon matched pair test. The median impedance at DFT for expiration and inspiration phases were 37.8 +/- 3.1 omega, and 39.3 +/- 3.6 omega, respectively (P = 0.02). The stored energy at DFT for expiration and inspiration phases were 5.7 +/- 1.9 J and 6.0 +/- 1.0 J, respectively (P = 0.594). Shocks delivered at end-inspiration exhibited a statistically significant increase in electrode impedance in a " hot can" electrode system. The finding that DFT energy was not significantly different at both respiration phases indicates that respiration phase does not significantly affect defibrillation energy requirements.

Animals↗

Additional lead improves defibrillation efficacy with an abdominal 'hot can' electrode system.

BACKGROUND: Although the left prepectoral site is preferred for "hot can" placement, this site is unavailable in some patients. We evaluated the influence of electrode location on defibrillation thresholds with alternative hot can and transvenous lead configurations. METHODS AND RESULTS: Three interrelated studies were performed. In group 1, the importance of hot can location was investigated by pairing a right ventricular lead to five different hot can placement sites in seven pigs. The defibrillation energies for right pectoral, left pectoral, left subaxillary, and right and left abdominal hot can sites were 20.3+/-2.7,* 15.9+/-3.8, 14.9+/-2.5, 32.0+/-3.4,* and 30.0+/-3.4 J,* respectively (*P<.005 versus left pectoral and left subaxillary sites). In group 2, the value of a three-electrode configuration with an abdominal hot can placement was investigated by adding a subclavian vein lead to the pectoral or abdominal hot can configurations in seven pigs. The defibrillation energies for left pectoral and abdominal sites were 18.6+/-4.2 and 29.0+/-5.8 J (P=.0001), respectively. The addition of a right or left subclavian vein lead with an abdominal hot can reduced the threshold to 19.3+/-4.2* or 18.8+/-3.2,* respectively (*P=.0001 versus abdominal site). In group 3, the contribution of the abdominal hot can electrode to the three-electrode configuration was tested by a comparison with two purely transvenous two-electrode configurations in six pigs. The defibrillation energy (19.9+/-3.2 J) for the abdominal hot can with a subclavian vein lead was lower than the transvenous lead configurations with a subclavian vein (29.0+/-2.5 J, P=.0001) or a superior vena cava lead (30.7+/-3.7 J, P=.0001). The right ventricular lead was the sole cathode during the first phase of the biphasic shock in all experiments. CONCLUSIONS: Defibrillation energy depends on the hot can placement site. The addition of a subclavian vein lead with an abdominal hot can improves defibrillation efficacy to the level of the pectoral placement and is better than a purely transvenous lead configuration.

Abdomen↗

Effects of polarity on defibrillation thresholds using a biphasic waveform in a hot can electrode system.

The polarity of a monophasic and biphasic shocks have been reported to influence DFTs in some studies. The purpose of this study was to evaluate the effect of the first phase polarity on the DFT of a biphasic shock utilizing a nonthoracotomy "hot can" electrode configuration which had a 90-microF capacitance. We tested the hypothesis that anodal first phase was more effective than cathodal ones for defibrillation using biphasic shocks in ten anesthetized pigs weighing 38.9 +/- 3.9 kg. The lead system consisted of a right ventricular catheter electrode with a surface area of 2.7 cm2 and a left pectoral "hot can" electrode with 92.9 cm2 surface area. DFT was determined using a repeated "down-up" technique. A shock was tested 10 seconds after initiation of ventricular fibrillation. The mean delivered energy at DFT was 11.2 +/- 1.7 J when using the right ventricular apex electrode as the cathode and 11.3 +/- 1.2 J (P = NS) when using it as the anode. The peak voltage at DFT was also not significantly different (529.0 +/- 41.3 and 531.8 +/- 28.6 V, respectively). We concluded that the first phase polarity of a biphasic shock used with a nonthroracotomy "hot can" electrode configuration did not affect DFT.

Animals↗

Sawtooth first phase biphasic defibrillation waveform: a comparison with standard waveform in clinical devices.

INTRODUCTION: A major limitation in a conventional truncated exponential waveform is the rapid drop in current that results in short duration of high current or longer duration with a lower average current. We hypothesized that increasing the first phase average current by boosting the decaying waveform prior to phase reversal may improve defibrillation efficacy. METHODS AND RESULTS: To better simulate a "rectangular" waveform during the first phase, a "sawtooth" defibrillation waveform was constructed using "parallel-series" switching of capacitances (each 30 microF) during the first phase. This permitted a boost in the voltage late in the first phase. This sawtooth biphasic waveform (sawtooth) was compared to two clinical waveforms: a 135-microF capacitance (control-1) and a 90-microF capacitance (control-2) waveform. Defibrillation threshold (DFT) parameters were evaluated in 13 anesthetized pig models using a system consisting of a transvenous right ventricular apex lead (anode) and a left pectoral "hot can" electrode (cathode) system. DFT was determined by a "down-up down-up" protocol. The stored energy for sawtooth, control-1, and control-2 was 10.5 +/- 2.8 J, 12.3 +/- 3.7 J*, and 12.2 +/- 2.8 J*, respectively (*P < or = 0.01 vs sawtooth). The average current of the first phase for sawtooth, control-1, and control-2 was 7.6 +/- 1.3 A, 4.7 +/- 0.9 A*, and 6.2 +/- 0.9 A*, respectively (*P = 0.0001 vs sawtooth). CONCLUSION: A sawtooth biphasic waveform utilizing a "parallel-series" switching system of smaller capacitors can improve defibrillation efficacy. A higher average current in the first phase generated by such a waveform may contribute to more efficient defibrillation by facilitating myocyte capture.

Animals↗

Optimized first phase tilt in "parallel-series" biphasic waveform.

INTRODUCTION: A biphasic defibrillation waveform can achieve a large second phase leading-edge voltage by a "parallel-series" switching system. Recently, such a system using two 30-microF capacitances demonstrated better defibrillation threshold than standard waveforms available in current implantable devices. However, the optimized tilt of such a "parallel-series" system had not been defined. METHODS AND RESULTS: Defibrillation thresholds were evaluated for five different biphasic "parallel-series" waveforms (60/15 microF) and a biphasic "parallel-parallel" waveform (60/60 microF) in 12 anesthetized pigs. The five "parallel-series" waveforms had first phase tilts of 40%, 50%, 60%, 70%, and 80% with second phase pulse width of 3 msec. The "parallel-parallel" waveform had first phase tilt of 50% with second phase pulse width of 3 msec. The defibrillation lead system comprised a left pectoral "hot can" electrode (cathode) and a right ventricular lead (anode). The stored energy at defibrillation threshold of the "parallel-series" waveform with first phase tilts of 40%, 50%, 60%, 70%, and 80% was 7.0 +/- 2.1, 6.1 +/- 2.8, 6.8 +/- 2.8, 7.2 +/- 2.9, and 8.4 +/- 3.1 J, respectively. The stored energy of the "parallel-series" waveform with a 50% first phase tilt was 16% less than the nonswitching "parallel-parallel" waveform (7.3 +/- 2.8 J, P = 0.006). CONCLUSIONS: A first phase tilt of 50% maximized defibrillation efficacy of biphasic waveforms implemented with a "parallel-series" switching system. This optimized "parallel-series" waveform was more efficient than the comparable "parallel-parallel" biphasic waveform having the same first phase capacitance and tilt.

Animals↗

Large change in voltage at phase reversal improves biphasic defibrillation thresholds. Parallel-series mode switching.

BACKGROUND: Multiple factors contribute to an improved defibrillation threshold of biphasic shocks. The leading-edge voltage of the second phase may be an important factor in reducing the defibrillation threshold. METHODS AND RESULTS: We tested two experimental biphasic waveforms with large voltage changes at phase reversal. The phase 2 leading-edge voltage was twice the phase 1 trailing-edge voltage. This large voltage change was achieved by switching two capacitors from parallel to series mode at phase reversal. Two capacitors were tested (60/15 microfarads [microF] and 90/22.5 microF) and compared with two control biphasic waveforms for which the phase 1 trailing-edge voltage equaled the phase 2 leading-edge voltage. The control waveforms were incorporated into clinical (135/135 microF) or investigational devices (90/90 microF). Defibrillation threshold parameters were evaluated in eight anesthetized pigs by use of a nonthoracotomy transvenous lead to a can electrode system. The stored energy at the defibrillation threshold (ion joules) was 8.2 +/- 1.5 for 60/15 microF (P < .01 versus 135/135 microF and 90/90 microF), 8.8 +/- 2.4 for 90/22.5 microF (P < .01 versus 135/135 microF and 90/90 microF), 12.5 +/- 3.4 for 135/135 microF, and 12.6 +/- 2.6 for 90/90 microF. CONCLUSIONS: The biphasic waveform with large voltage changes at phase reversal caused by parallel-series mode switching appeared to improve the ventricular defibrillation threshold in a pig model compared with a currently available biphasic waveform. The 60/15-microF capacitor performed as well as the 90/ 22.5-microF capacitor in the experimental waveform. Thus, smaller capacitors may allow reduction in device size without sacrificing defibrillation threshold energy requirements.

Animals↗