Urinary tract abnormalities in children with acute focal bacterial nephritis.

OBJECTIVE: To review the presentation, methods of diagnosis, and incidence of concomitant urological abnormalities in children with acute focal bacterial nephritis (AFBN, also known as lobar nephronia, a severe nonliquefactive infection involving one or more renal lobules). PATIENTS AND METHODS: Sixteen children (age range 6 months to 9 years) diagnosed with AFBN over a 5-year period were retrospectively reviewed. Their age, gender, presenting symptoms, presence of urinary tract abnormalities, radiological imaging and treatment were assessed. RESULTS: All 16 children received intensive intravenous and oral antibiotics. Ten required intervention for predisposing conditions including vesico-ureteric reflux (four), bladder diverticulum (one), renal and peri-rectal abscess (two), ureteric or bladder calculi (two), and renal mass (one). In addition, three children had reflux not requiring surgery; one had multiple renal calyceal diverticula, one had Hinman syndrome and one had leukaemia. CONCLUSION: Acute focal bacterial nephritis is being diagnosed with increasing frequency through increasing awareness and advances in imaging modalities. Active urological evaluation is warranted because of the high incidence of urinary tract abnormalities. In addition to antibiotics, intervention was needed in most children in this series.

Acute Disease↗

Breast imaging trends in Wisconsin.

UNLABELLED: This survey was performed to determine what breast imaging services are being offered in Wisconsin and compare this information to a similar survey performed in 1997 looking for any developing trends. METHODS: A survey of participants at the University of Wisconsin Mammography Update Continuing Education Conference of 1999 was performed. Of the 135 questionnaires distributed, 68 were returned fully completed and 2 partially completed. RESULTS: The majority of sites were located in Wisconsin with 59 diagnostic facilities and 57 screening facilities surveyed (some participants were involved with more than one facility). Overall there has been a marked increase in the number of sites having some type of women's imaging center and there has been an increase in the volume and type of breast interventions performed by medical imagers. CONCLUSION: Breast imaging and breast interventions are increasing rapidly with increased involvement of the medical imager in the diagnosis and management of breast disease.

Adult↗

Radiology faculty evaluation: bi-institutional implementation of an experimental appraisal instrument.

RATIONALE AND OBJECTIVES: The authors evaluated the reliability and validity of an experimental radiology faculty appraisal instrument. MATERIALS AND METHODS: Residents from the University of Wisconsin (UW) and Indiana University (IU) were asked to use a previously developed behaviorally based, 53-item experimental faculty appraisal instrument. Twenty UW residents evaluated 29 UW faculty members and 37 IU residents evaluated 31 IU faculty members by using the experimental instrument. Residents also evaluated faculty by using their institution's existing appraisal instrument. RESULTS: Correlations between existing and experimental forms were .69 and .87 for UW and IU, respectively. Existing form reliabilities were .89 and .94 and experimental form reliabilities were .98 and .98 for UW and IU, respectively. Experimental form length was reduced to 30 items by eliminating the questions that correlated the least with section scores. Reliabilities of scores on the shortened form were .97 and .98 and correlated .65 and .88 with scores on the longer form for UW and IU, respectively. CONCLUSION: Ratings obtained with the existing forms correlated substantially with the experimental form, attesting to the experimental form's validity. Shortening the experimental form had a minimal effect on the reliability and validity of the data obtained. The behavior-based form was used to rate behaviors that residents believed discriminated between effective and ineffective instructors, enabling an objective and relevant assessment to be made.

Adult↗

Mammography facility trends across Wisconsin.

This paper summarizes the survey results obtained from the University of Wisconsin Mammography Update CME conference. This survey queried participants regarding the breast imaging services they offer. From 147 questionnaires distributed, 110 were returned. The majority of sites were in Wisconsin and were hospital based (57%). Thirty three percent were in clinic settings and 11 percent were "other" settings-clinics specializing in women's health and breast imaging. The survey addressed coordinated breast physical examinations, prior mammographic studies, self-referral, communication of mammographic results, patient call-backs for additional studies, breast compression, breast implants, scheduling, definitions of screening and diagnostic mammograms, presence of an on-site radiologist, and time allotted for the examinations. This survey attempted to gather useful information about the trends and practices of multiple diverse mammography facilities across Wisconsin and in surrounding states.

Breast Neoplasms↗

Development of a radiology faculty appraisal instrument by using critical incident interviewing.

RATIONALE AND OBJECTIVES: To develop a valid and reliable radiology faculty appraisal instrument based on scientific methods. MATERIALS AND METHODS: Fifteen radiology residents participated in critical incident interviewing. During a 1-hour interview, a resident was asked to describe five incidents each of effective and ineffective faculty behavior. Two investigators independently listened to the tape-recorded interviews, and two different investigators sorted the incidents into broad categories. A faculty appraisal instrument was developed by listing similar incidents under broad categories. A five-point rating scale was applied to each item. Content validity was assessed by resident and faculty critique of the appraisal instrument. RESULTS: A total of 168 incidents of faculty behavior were generated. The frequency with which similar incidents were reported was recorded. The most common behaviors reported were related to staff expertise and teaching. Interjudge reliability was good, as determined by computing K indices of agreement (overall K = 0.59). There was good agreement regarding instrument content validity among residents but not among faculty. CONCLUSION: Residents supported the use of the new appraisal instrument, but further tests of validity and reliability and faculty acceptance of the instrument will determine its usefulness as a tool for monitoring faculty teaching performance and making decisions regarding faculty promotion.

Faculty, Medical↗

Conventional color Doppler velocity sonography versus color Doppler energy sonography for the diagnosis of acute experimental torsion of the spermatic cord.

OBJECTIVE: We compared color Doppler velocity sonography and color Doppler energy sonography for the diagnosis of spermatic cord torsion in a canine model and determined the degree of torsion necessary to acutely halt testicular blood flow. MATERIALS AND METHODS: Spermatic cord torsion was created in five dogs by exposing and rotating the ipsilateral testis 0 degree, 180 degrees, 270 degrees, 360 degrees, 450 degrees, and 540 degrees. Detorsion followed. The testicles were scanned at each torsion stop using both color Doppler velocity sonography and color Doppler energy sonography. Doppler parameters were optimized (by phantom and test scans) and maintained at a tolerable noise level throughout the experiment. Readers who were unaware of the degree of torsion compared flow in the rotated and contralateral control testes. RESULTS: Flow became undetectable by color Doppler velocity sonography and color Doppler energy sonography at 450 degrees in four of five cases and at 540 degrees in one of five cases. We found no significant difference between the velocity and the energy techniques for detecting this absence of flow (p > .05, Wilcoxon test). We found a significant difference in degree of flow for both techniques when comparing controls and all degrees of torsion combined (p < .006, Mann-Whitney test), but significance was achieved at lesser degrees of torsion with the velocity technique than with the energy technique (180 degrees and 360 degrees, respectively, Wilcoxon test). CONCLUSION: Color Doppler energy sonography was not significantly more sensitive than color Doppler velocity sonography for the diagnosis of spermatic cord torsion in this model. Complete occlusion of arterial inflow occurred at 450-540 degrees of torsion.

Animals↗

Advantages and disadvantages of three-dimensional computed tomography intraoperative localization for functional endoscopic sinus surgery.

Intraoperative three-dimensional computed tomography (3-D-CT) localization has been available for use during functional endoscopic sinus surgery (FESS) for several years, although relatively few otolaryngologists operate in conjunction with this technology. Proponents of intraoperative localization believe that operating with stereotaxis enhances surgical precision and reduces complications. A 1-year review was conducted at the University of Pennsylvania from January 1994 through January 1995. During this period 5% of sinus operations were performed in conjunction with intraoperative localization. The advantages and disadvantages of using intraoperative localization were evaluated for each case. Also examined were type and indication for surgery, anesthesia used, added time, and cost. Overall, intraoperative localization was found to be helpful when anatomy was distorted or obscured. However, selecting patients who may have benefited from localization was often not possible using preoperative data. Ideally, localization should be available for all FESS. Criteria are outlined which will need to be met prior to localization becoming a significant aspect of FESS.

Adult↗

Utility of axillary views in postmastectomy patients.

This study was performed to determine the utility of routine axillary radiography in postmastectomy patients. The records of 185 postmastectomy patients who had undergone axillary radiography were retrospectively reviewed. Of 499 views obtained, only 10 (2%) were reported as abnormal. Only one of the 10 patients with abnormal studies had a demonstrated recurrence that corresponded to the mammographic finding. This patient also had positive physical examination results at that time. Eight of the 185 patients developed local recurrences, four of which were in the axilla of the affected side. These four cases were all detected at physical examination; two patients underwent relatively concurrent axillary radiography. One of these two patients with abnormal physical examination results had a positive axillary view obtained in the same month. The other of these two patients with abnormal physical examination results had a negative axillary view obtained 3 months earlier. The authors conclude that routine axillary radiography is not useful in postmastectomy patients.

Axilla↗

Spectral and color Doppler artifacts.

Artifacts in spectral and color Doppler imaging can be confusing and lead to misinterpretation of flow information. The authors review these artifacts by considering three main causes: inappropriate equipment settings, anatomic factors, and physical and technical limitations of the modality. Incorrect gain, wall-filter, or velocity scale settings can cause loss of clinically important information or distortion of the tracing. Reflection of the Doppler signal from highly reflective surfaces can create a color Doppler mirror image. Vascular motion can introduce artifactual variation in velocity as the sample volume passes through different velocities in a laminar flow state. Unintentional motion can cause a generalized Doppler shift. Increasing the angle of Doppler interrogation degrades the quality of the tracing and gives the impression of spectral broadening. As angulation approaches 90 degrees, directional ambiguity can occur, suggesting bidirectional flow. Grating and side lobes can interrogate areas unrelated to the sample volume and introduce extraneous Doppler information to the apparent area of interrogation. Recognition of these artifacts is essential to proper interpretation of Doppler information and rendering a correct diagnosis.

Artifacts↗