PubMed Health⌕ Search

Biomedical subjects

K A Wick

Publications and source records attributed to K A Wick.

7 recordsLinked to original sources

Evaluation of conventional press-and-breathe metered-dose inhaler technique in 501 patients.

Conventional press-and-breathe metered dose inhalers (MDIs) are widely prescribed but are often difficult for many patients to properly use. A total of 501 patients from different medical specialties were enrolled in this study, which evaluated how the patients used their MDIs. Using a conservative method (minimum number of errors) of determining errors, we found that 388 (77.5%) of the patients made at least one error when demonstrating how they use their MDI for two observers. Using a liberal (maximum number of errors) method of analysis, we found that 447 (89.2%) of the patients made at least one error. There was no difference in errors made stratified by patient gender, patient age, or the medical specialty that treated the patient's pulmonary disease. The two most common errors made by patients were failure to breathe out to functional residual capacity before actuation (225 by minimum method, 280 by maximum method) and not actuating the canister at the start of inhalation (207 by minimum method, 323 by maximum method). Of the patients with improper timing of actuation, the majority (121 patients by minimum method and 187 patients by maximum method) actuated the canister early. In this large patient sample, regardless of which medical specialty provided the treatment, the majority of the patients evaluated had less than optimal MDI technique. Routine assessment of MDI technique should be instituted as standard practice care.

Adolescent↗

Kinetics of absorption of a new once-a-day formulation of theophylline in the presence and absence of food.

Two three-way crossover studies were done to characterize the drug release characteristics of Monospan (3M Pharmaceuticals, St. Paul, MN) capsules, a new once-a-day theophylline formulation. In the first study, 22 healthy males received single 450-mg doses of Monospan in the presence and absence of a high-fat breakfast; the same dose of Somophyllin (Fisons, Rochester, NY) immediate-release liquid was given to fasted subjects as a reference. The second study involved 29 healthy males given a single dose of 900 mg of Monospan in the presence and absence of the same high-fat meal; Theo-24 (G. D. Searle and Co., Skokie, IL) capsules were given to fasted subjects as a reference. The results of both studies showed that food did not affect the absorption of theophylline from Monospan; peak concentration, to and area under the serum concentration-time curve were all unchanged. The absorption rates were similar with both strengths and dietary conditions and showed that theophylline was absorbed slowly from Monospan at a constant rate (approximately 3.2%/h) over 24 h. Absorption continued past 24 h, and the extent of absorption from Monospan compared with that from each reference averaged 88% or higher. A good correlation (r > 0.980) was observed for Monospan between the amount absorbed in vivo and the amount released in the in vitro dissolution test, a result that demonstrates the precise rate control of Monospan. We conclude that Monospan is a suitable once-a-day formulation that can be taken without regard to food.

Absorption↗

Comparative absorption of atropine from a metered-dose inhaler and an intramuscular injection.

The inhalation of atropine sulfate from a pressurized metered-dose inhaler was investigated in a nonrandomized four-period rising-dose study. Eight healthy, nonsmoking subjects received 1.7, 3.4, and 5.2 mg of atropine sulfate by inhalation and 1.67 mg of atropine free base (equivalent to 2 mg of atropine sulfate) by intramuscular (i.m.) injection. Serum atropine sulfate concentrations were measured over a 24-h period by gas chromatography/mass spectrometry. Mean serum concentrations increased nonproportionally as the inhaled dose increased. Mean peak concentrations were 4.9, 6.1, and 7.9 ng/ml for the inhaled doses and 8.4 ng/ml for the i.m. dose. Typical anticholinergic effects were seen after all doses.

Absorption↗

Pharmacokinetic properties of sustained-release theophylline (Theolair-SR) in relation to timing of doses after low-fat meals.

Pharmacodynamic and pharmacokinetic properties of sustained-release anyhdrous theophylline (Theolair-SR) were similar when doses were given either immediately after or two hours after low-fat meals in children with moderate asthma requiring daily theophylline maintenance. Asthma and pulmonary function values were maintained and approached values for healthy subjects during both treatment regimens.

Adolescent↗

Performance of a new transdermal nitroglycerin adhesive patch formulation.

This two-period crossover study in 24 healthy men compared the transdermal absorption of nitroglycerin from a new 20-cm2 nitroglycerin adhesive transdermal patch applied for a single 24-hour period (q24hr) with that from one inch of 2% nitroglycerin ointment applied over a 50-cm2 area every eight hours (q8hr) during a single 24-hour period. The observed differences in pharmacokinetic parameters were expected, based on product design (q24hr vs q8hr) and surface area (20 cm2 vs 50 cm2); however, when corrected for surface area, the mean plasma AUC ratios indicated that the patch delivered about 1.5 times more drug than the ointment. The patch delivery of nitroglycerin was confirmed by patch residual results, which indicated nitroglycerin was released at a rate of 0.75 mg/cm2/24 hrs. The patch exhibited good skin adhesion throughout the 24-hour application period.

Administration, Cutaneous↗

Drug release rates from four sizes of a new transdermal nitroglycerin adhesive patch.

This study was conducted to determine the amount of nitroglycerin released from transdermal nitroglycerin patches of four different sizes: 3.3 cm2, 6.7 cm2, 13.3 cm2, and 20 cm2. Thirty healthy men received a single 24-hour application of each patch size according to a randomized, open-label, four-period crossover design. A 24-hour interval separated each treatment period. The total amount of nitroglycerin released by the four patches was proportional to size. All four patch sizes released nitroglycerin at a comparable rate. The mean overall 24-hour release rate of 0.76 mg/cm2 was similar to the release rate of 0.75 mg/cm2/24 hr observed in a previous study. Adverse experiences common to nitroglycerin administration were reported for all patch sizes, with headache, light-headedness, and nausea reported most frequently.

Administration, Cutaneous↗

Adhesion-to-skin performance of a new transdermal nitroglycerin adhesive patch.

Six men and six women participated in a study designed to compare adhesion-to-skin measurements of three transdermal nitroglycerin patch formulations (Minitran, Transderm-Nitro 5, and Nitro-Dur II) with an occlusive surgical tape control. After 24 hours of wear, Minitran was found to be superior to the other three products in skin adhesion. The force required to remove Minitran was significantly higher than that required to remove the other products. Maintaining good skin contact over the entire application period is essential for consistent drug delivery. Improved skin contact can increase transdermal drug delivery. This increase in delivery of nitroglycerin may result in the development of smaller patches rated to deliver the same quantity of nitroglycerin over a 24-hour period.

Adhesiveness↗