PubMed Health⌕ Search

Biomedical subjects

K Andersen

Publications and source records attributed to K Andersen.

At least 145 records · Page 8Linked to original sources

Treatment of clavicular fractures. Figure-of-eight bandage versus a simple sling.

Seventy-nine out-patients with midclavicular fractures were included in a prospective, randomized trial comparing treatment with a figure-of-eight bandage and a simple sling. Sixty-one patients completed the study and were reevaluated clinically and radiographically after 3 months. We found that treatment with a simple sling caused less discomfort and perhaps fewer complications than with the figure-of-eight bandage. The functional and cosmetic results of the two methods of treatment were identical and alignment of the healed fractures was unchanged from the initial displacement.

Adolescent↗

Brain microvascular function during cardiopulmonary bypass.

Emboli in the brain microvasculature may inhibit brain activity during cardiopulmonary bypass. Such hypothetical blockade, if confirmed, may be responsible for the reduction of cerebral metabolic rate for glucose observed in animals subjected to cardiopulmonary bypass. In previous studies of cerebral blood flow during bypass, brain microcirculation was not evaluated. In the present study in animals (pigs), reduction of the number of perfused capillaries was estimated by measurements of the capillary diffusion capacity for hydrophilic tracers of low permeability. Capillary diffusion capacity, cerebral blood flow, and cerebral metabolic rate for glucose were measured simultaneously by the integral method, different tracers being used with different circulation times. In eight animals subjected to normothermic cardiopulmonary bypass, and seven subjected to hypothermic bypass, cerebral blood flow, cerebral metabolic rate for glucose, and capillary diffusion capacity decreased significantly: cerebral blood flow from 63 to 43 ml/100 gm/min in normothermia and to 34 ml/100 gm/min in hypothermia and cerebral metabolic rate for glucose from 43.0 to 23.0 mumol/100 gm/min in normothermia and to 14.1 mumol/100 gm/min in hypothermia. The capillary diffusion capacity declined markedly from 0.15 to 0.03 ml/100 gm/min in normothermia but only to 0.08 ml/100 gm/min in hypothermia. We conclude that the decrease of cerebral metabolic rate for glucose during normothermic cardiopulmonary bypass is caused by interruption of blood flow through a part of the capillary bed, possibly by microemboli, and that cerebral blood flow is an inadequate indicator of capillary blood flow. Further studies must clarify why normal microvascular function appears to be preserved during hypothermic cardiopulmonary bypass.

Animals↗

Detection of glass foreign bodies by radiography.

During a 14-month period patients with suspected glass foreign bodies were radiographically examined before removal of the glass. In 25 out of 26 patients the glass foreign bodies were detected. In 9 patients the glass foreign bodies had been overlooked on previous visits to doctors or hospitals, where the examination had been limited to inspection and sometimes probing of the wound. Almost all glass foreign bodies can be detected radiographically. With high-resolution or mammographic techniques even minute splinters may show up.

Adult↗

Left main or proximal left anterior descending coronary artery disease: detection by echocardiographic evaluation of interventricular septal function during exercise.

Forty patients with coronary artery disease were studied prospectively to investigate whether stenosis of the left main (LMCA) or left anterior descending coronary artery, proximal to the first septal branch (proximal LAD), could be detected by M-mode echocardiography during exertion. The interventricular septum was visualized in 30 of the patients during bicycle exercise in the semisupine position, all with simultaneous occurrence of electrocardiographic evidence of myocardial ischaemia. Fifteen of these had LMCA or proximal LAD stenosis. Systolic motion and thickening of the septum decreased significantly from rest to peak exercise in patients with LMCA or proximal LAD disease while it increased in those without. The results suggest that M-mode echocardiography during exercise in patients with coronary artery disease might identify those with LMCA or proximal LAD stenosis.

Adult↗

Brain oedema and blood-brain barrier permeability in pulsatile and nonpulsatile cardiopulmonary bypass.

In pigs subjected to pulsatile or nonpulsatile cardiopulmonary bypass (CPB) at normothermia for 3 hours, evaluation was made of water content in brain tissue (specific gravity measurements), blood-brain permeability to serum proteins (immunocytochemical demonstration of extravasated proteins, using peroxidase-antiperoxidase technique) and histopathology (paraffin sections). The specific gravity in parietal cortex was higher after pulsatile than after nonpulsatile CPB or in control pigs, the change corresponding to a 6.3% water increase. The tissue water content was unchanged in the internal capsule, basal ganglia and nucleus accumbens after CPB. The vascular permeability to serum proteins was unchanged after nonpulsatile CPB, but after pulsatile CPB minute foci of extravasated serum proteins appeared. All the animals showed dark neurons in cortical and subcortical regions, but these could have been artefacts in immersion-fixed tissue. There were no other signs of ischaemic tissue damage. The study indicated that cortical oedema may follow pulsatile CPB, the cause being altered permeability of the blood-brain barrier to serum proteins.

Animals↗

Dislocation of the superior tibiofibular joint.

Derangements of the superior tibiofibular joint are divided into anterolateral, posteromedial and superior dislocations and chronic instability. Two cases of anterolateral dislocation, both needing open reduction, are presented together with a case of posteromedial dislocation.

Adolescent↗

Pulsatile flow during cardiopulmonary bypass. Evaluation of a new pulsatile pump.

Pulsatile cardiopulmonary bypass (CPB) has been suggested to be superior to nonpulsatile CPB. This report concerns a newly developed pulsatile pump for clinical use. It is designed as a positive displacement pump, with blood allowed to collect in a valved cavity from which it is ejected by the reciprocating action of a piston. Using a uniform procedure of anaesthesia and surgery, 14 pigs were subjected to CPB at 37 degrees C for 3 hours. The pulsatile pump was used in seven pigs and a conventional roller pump in the other seven. The wave-form of the pulse during pulsatile CPB was similar to that recorded in the pigs before bypass. The values for rate of pressure change with respect to time (dp/dt) obtained in the aorta were close to the pre-CPB values. No difference was found between the two groups with respect to platelet count or haemolysis. The investigated pulsatile device appeared to be reliable and easy to handle, and the pulsation it produced closely resembled the physiologic pulse-wave form.

Animals↗