PubMed Health⌕ Search

Biomedical subjects

K Ariniemi

Publications and source records attributed to K Ariniemi.

5 recordsLinked to original sources

Detection and assay of cis- and trans-isomers of 4-methylaminorex in urine, plasma and tissue samples.

The 4-methylaminorex (4-MAX) is an amphetamine-related psychostimulant drug that has appeared on the clandestine market with a street name of "U4Euh". This compound exists as four stereoisomers, trans-4R,5R, trans-4S,5S, cis-4R,5S and cis-4S,5R, of which the cis forms have been classified as Schedule I substances in the US. The increasing variety of designer drugs has highlighted the importance of detection, identification, and quantitative measurement of these drugs, including 4-MAX, in biological samples. In the present study, the isomers of 4-MAX were detected in urine of rats treated with the drugs by some but not all of the on-site immunoassays tested, mainly as amphetamine or methamphetamine. To facilitate identification of 4-MAX by laboratories specialized in drug analysis, the electron-ionization mass spectrum and TLC data for underivatized 4-MAX using a routine laboratory drug-screening procedure is provided. In addition, a GC/MS method is described for the quantitative determination of cis- and trans-4-MAX as tert-butyldimethylsilyl-derivatives in plasma, urine and tissue.

Animals↗

Oxalic acid stabilizes dopamine, serotonin, and their metabolites in automated liquid chromatography with electrochemical detection.

Use of antioxidative agents is required in automated LC assay of microdialysis samples, due to rapid degradation of the monoamine neurotransmitters and their metabolites. Addition of oxalic acid prevented degradation of dopamine, serotonin, 3,4-dihydroxyphenylacetic acid, homovanillic acid and 5-hydroxyindoleacetic acid efficiently: after a 24-h incubation at room temperature the decreases in peak heights were less than 10%. The long-term stability of the analytes, however, was still enhanced when acetic acid and L-cysteine were included in the solution. Using this antioxidative solution, the monoamine neurotransmitters and their metabolites could be determined with an automated LC assay even at room temperature.

Automation↗

GCD quantitation of opiates as propionyl derivatives in blood.

We describe a method using a gas chromatograph with electron ionization detection (GCD) for the simultaneous determination of morphine, codeine, 6-monoacetylmorphine, ethylmorphine, and dihydrocodeine in blood. The method employs propionic anhydride in the presence of triethylamine to propionylate free hydroxyl groups of the opiates in blood. The quantitation is achieved by using GCD with selected ion monitoring of the two most characteristic ions for each analyte. The quantitation limit was 0.01 mg/L and the linearity was 0.01-10 mg/L for dihydrocodeine, ethylmorphine, and 6-monoacetylmorphine. For the other investigated opiates, the quantitation limit was 0.025 mg/L and linearity was 0.025-10 mg/L. The intraday relative standard deviation (RSD) varied from 7.2 to 10% at the 0.5 mg/L level, and the day-to-day RSDs varied from 7.5 to 11% at the 0.85 mg/L level.

Anhydrides↗

Validated method for the quantitation of quercetin from human plasma using high-performance liquid chromatography with electrochemical detection.

A validated method for the quantitation of trace levels of quercetin from human plasma to be used in pharmacokinetic and biomarker studies is presented. Quercetin conjugates were hydrolysed enzymatically, plasma proteins were removed using a Bond Elut C18 extraction column and additional interferences were removed by extracting them into a toluene-dichloromethane mixture. The HPLC system consisted of an Inertsil ODS-3 column (250 x 4.0 mm) and a mobile phase with 59% methanol in phosphate buffer (pH 2.4). High selectivity and a low quantitation limit (0.63 microg/l) were achieved by using electrochemical detection at a low potential. The method has excellent reproducibility: R.S.D. values of peak-heights were 2% and 7.9%, respectively, for within-day and between-day precision. The method was applied to a small scale study of quercetin pharmacokinetics and quercetin was shown to be absorbed from a 20 mg dose. No free quercetin was detected in plasma and no evidence of significant amounts of quercetin glycosides in plasma was found.

Chromatography, High Pressure Liquid↗

Comprehensive drug screening in blood for detecting abused drugs or drugs potentially hazardous for traffic safety.

A comprehensive drug screening procedure for detecting drugs in the blood samples of car drivers suspected of driving under the influence of drugs, is presented. Amphetamines, cannabinoids, opioids, cocaine and benzodiazepines were screened by an immunological EMIT ETS system after acetone precipitation. Gas chromatographic methods were used to screen and quantitate basic, neutral and acidic drugs. The free amino groups of basic drugs were derivatized with heptafluorobutyric anhydride. Analysis was performed by a dual channel gas chromatograph combined with a nitrogen phosphorus and an electron capture detector. Phenyltrimethylammonium hydroxide was used as a methylathing agent for acidic substances before analysis with a gas chromatograph connected to a nitrogen phosphorus detector. A gas chromatograph/mass spectrometry was used as a common confirmation method. Tetrahydrocannabinol was quantitated after bis(trimethylsilyl)trifluoroacetamide derivatization, opiates after pentafluoropropionic anhydride derivatization and benzoylecgonine after pentafluoropropionic anhydride and pentafluoropropanol derivatization. Excluding benzodiazepines, which were confirmed with a gas chromatograph connected to a nitrogen phosphorus and an electron capture detector, the other basic drugs as well as the acidic drugs were confirmed after the same derivatization procedures as in the screening methods. Alcohols were quantitated in triplicate by gas chromatography using three different kinds of columns. Although urine is the most important specimen for screening abused drugs, it has only limited use in forensic toxicology. The described system is most useful for analyzing a wide range of substances, including illicit drugs, benzodiazepines, barbiturates, antidepressants and phenothiazenes in forensic samples when urine is not available.

Accidents, Traffic↗