Effect of systolic flow rate on the prediction of effective prosthetic valve orifice area.

The Gorlin equation for the hemodynamic assessment of valve area is commonly used in cardiac catheterization laboratories. A study was performed to test the prediction capabilities of the Gorlin formula as well as the Aaslid and Gabbay formula for the effective orifice area of prosthetic heart valves. Pressure gradient, flow, and valve opening area measurements were performed on four 27 mm valve prostheses (two mechanical bileaflet designs, St. Jude and Edwards-Duromedics, an Edwards pericardial tissue valve, and a trileaflet polyurethane valve) each mounted in the aortic position of an in vitro pulse duplicator. With the known valve orifice area, a different discharge coefficient was computed for each of the four valves and three orifice area formulas. After some theoretical considerations, it was proposed that the discharge coefficient would be a function of the flow rate through the valve. All discharge coefficients were observed to increase with increasing systolic flow rate. An empirical relationship of discharge coefficient as a linear function of systolic flow rate was determined through a regression analysis, with a different relationship for each valve and each orifice area formula. Using this relationship in the orifice area formulas improved the accuracy of the prediction of the effective orifice area with all three formulas performing equally well.

Blood Flow Velocity↗

Effect of prosthetic mitral valve geometry and orientation on flow dynamics in a model human left ventricle.

Pulsatile flow dynamics through bileaflet (St Jude and Duromedics), tilting disc (Bjork-Shiley and Omniscience), caged ball (Starr-Edwards), pericardial (Edwards) and porcine (Carpentier-Edwards) mitral valves in a model human left ventricle (LV) were studied. The model human ventricle, obtained from an in situ diastolic casting, was incorporated into a mock circulatory system. Measurements were made at various heart rates and flow rates. These included the transvalvular pressure drop and regurgitation in percent and cm3 beat-1. The effect of valve geometry and the orientation of the valve with respect to the valve annulus was analyzed using a flow visualization technique. Qualitative flow visualization study indicates certain preferred orientations for the tilting disc and bileaflet valve prostheses in order to obtain a smooth washout of flow in the LV chamber.

Heart↗

Experimental fluid dynamics of aortic stenosis in a model of the human aorta.

Aortic stenosis has been modelled in an in vitro, pulsatile mock circulatory system (MCS) using a porcine valvular prosthesis, and studied with a laser Doppler anemometer (LDA). The MCS incorporated an acrylic model of the human aorta made from a cadaveric casting in situ. A Carpentier-Edwards aortic valve prosthesis was placed in the MCS after being rendered stenotic by suturing of the valve cusps. Flow velocity profiles across the lumen of the aorta in the presence of aortic stenosis were determined using LDA at two preselected sites in the ascending aorta, and at one preselected site in the brachiocephalic artery. Results indicate that a strong systolic jet bordered by transient vortices with intensely reversed flows is produced distal to severely stenotic aortic valves, becoming less intense with a lesser degree of stenosis. Peak fluid velocities in the systolic jet were determined by LDA at distances of 2.6 and 5.6 cm from the valve inlet for a mean flow rate of 5.2 l min-1. Peak systolic pressure gradients and peak turbulent axial stresses were also determined and found to increase dramatically with stenosis. Furthermore, increasing degrees of stenosis also resulted in more severely disturbed flows in the brachiocephalic artery. Peak fluid velocities and their associated turbulent axial stresses in the systolic jets produced by aortic valvular stenosis are remarkably sensitive to even small changes in the calculated valve orifice areas, and can therefore be very useful in assessing the severity and progression of valvular disease. In addition, increasing degrees of aortic stenosis cause more turbulence to be transported into the brachiocephalic artery.

Aorta↗

In vitro comparison of velocity profiles and turbulent shear distal to polyurethane trileaflet and pericardial prosthetic valves.

A comparative study of flow dynamics past biomer trileaflet valves and a pericardial bioprosthetic valve under steady and physiological pulsatile flow conditions in vitro is reported in this paper. The velocity profiles and the turbulent shear stresses distal to the valves were measured using laser Doppler anemometry. The authors' results showed that the velocity profiles distal to the trileaflet valves were similar to that measured distal to the pericardial valve. Higher magnitudes of absolute turbulent shear stresses were measured distal to the synthetic valves in comparison to the pericardial valves. However, when the stresses were nondimensionalized with respect to the orifice diameter at the inlet aspect, the stresses were comparable for all of the three valves. With design modifications to increase the orifice diameter at the inlet aspect of the polyurethane valves, the turbulent stresses distal to the valves can be minimized. Such in vitro studies on the flow dynamics past the polyurethane valves can provide information towards design changes to improve the performance characteristics of these valves. Polyurethane valves with flow characteristics comparable to the pericardial valves can be manufactured relatively inexpensively compared to mechanical or tissue valve prosthesis. Hence, the synthetic valves may be a viable alternative for short-term use in total artificial heart devices as a bridge to transplant.

Bioprosthesis↗

An in vitro comparative study of St. Jude Medical and Edwards-Duromedics bileaflet valves using laser anemometry.

An in vitro comparative study of St. Jude (SJ) and Edwards-Duromedics (DM) Bileaflet valves was performed under steady and physiological pulsatile flow conditions in an axisymmetric chamber using Laser Doppler Anemometry (LDA). LDA measurements were conducted in two different orientations; in the first orientation, the LDA traverse was perpendicular and, in the second orientation, parallel to the tilt axis of the leaflets. The axial velocities were measured in both orientations at two different locations distal to the valves. The velocity profiles at peak systole show the presence of stronger vortex in the sinus region for flow past SJ valve in the first orientation compared to the DM valve. Velocity profile distal to the SJ valve in second orientation was relatively flat where as for the DM valve, a jet-like flow was present. The differences found in the velocity profiles between the two valves can be attributed to the differences in geometry with thicker leaflets, smaller angle of leaflets opening and the presence of the leaflet curvature for the DM valve. The results obtained in this study do not show any fluid dynamic advantages due to the curved leaflet geometry of the DM valve.

Biomechanical Phenomena↗

An in vitro experimental comparison of Edwards-Duromedics and St Jude bileaflet heart valve prostheses.

An in vitro comparison of the hydrodynamic characteristics of the Edwards-Duromedics (DM) and St Jude (SJ) bi-leaflet aortic valve prostheses is presented. Aortic valves 27 mm in diameter were mounted in a pulse duplicator simulating physiological pulsatile flow using a glycerol solution as the blood analogue fluid. Mean trans-valvular pressure difference (TPD) in systole, the per cent regurgitation (PCR) and the projected valve orifice area (VOA) were compared at a range of flow rates and heart rates to reflect the functioning of the valve under resting as well as exercise conditions. Our results showed that the TDP for DM (0.99 +/- 0.28 kPa) valve was slightly larger than the SJ (0.81 +/- 0.19 kPa) valve (mean difference of 0.18 +/- 0.26 kPa, P less than 0.05). However, the PCR for the DM (13.6 +/- 7.8) valve was smaller than the SJ (17.9 +/- 9.0) valve (mean difference of 4.3 +/- 4.2%, P less than 0.01). Moreover, VOA for the DM (2.51 +/- 0.10 cm2) valve was smaller than the SJ (3.13 +/- 0.04 cm2) valve (mean difference of 0.63 +/- 0.10 cm3, P less than 0.001).

Aortic Valve↗

Detection, localization, and quantitation of bioprosthetic mitral valve regurgitation. An in vitro two-dimensional color-Doppler flow-mapping study.

The usefulness of two-dimensional color-Doppler flow-imaging (2D Doppler) in the detection, localization, and quantitation of bioprosthetic mitral valve regurgitation is uncertain. Mitral bioprostheses, before and after the creation of transvalvular (n = 33), paravalvular (n = 17), or combined (n = 23) defects, were mounted in a pulsed duplication system (flow rates, 2.5-6.5 l/min; pulse rate, 70 beats/min). An Aloka 880 2D Doppler system (Japan) was used to image the regurgitant jets in the simulated left atrial chamber, analogous to images obtained with transesophageal echocardiography. Jet area was corrected to an estimate of stroke volume: 2D Doppler measurements were divided by [(valve effective orifice area) X (continuous-wave Doppler-determined mean diastolic filling velocity)]/pulse rate. Regurgitant fraction and regurgitant volume were measured by an electromagnetic flow probe. 2D Doppler correctly identified the presence and location of paravalvular regurgitation. In transvalvular and combined transvalvular-paravalvular defects, there were six incorrect interpretations, all having transvalvular regurgitant volumes less than 4 ml/beat. In the presence of transvalvular regurgitation, jet area, length, and width correlated linearly with regurgitant volume (r = 0.82, 0.80, and 0.68, respectively; p less than 0.0001) and regurgitant fraction (r = 0.62, 0.61, and 0.45, respectively; p less than 0.001). Correlations with regurgitant fraction were improved when 2D Doppler measurements were corrected for stroke volume (r = 0.78, 0.79, and 0.67, respectively; p less than 0.0001). Mitral bioprostheses with transvalvular defects were also studied at varying flow rates (3.2-7.5 l/min) and pulse rates (70, 90, and 110 beats/min). The correlation between jet area and regurgitant volume was improved with a second-order polynomial regression (r = 0.93, p less than 0.0001). Our conclusions are that 1) in this in vitro model analogous to transesophageal imaging, 2D Doppler accurately detects and localizes bioprosthetic mitral valve regurgitation; 2) in transvalvular bioprosthetic mitral valve regurgitation, 2D Doppler measurement of jet area has a curvilinear relation with regurgitant volume, and correlation with regurgitant fraction is improved with correction for stroke volume; and 3) in paravalvular bioprosthetic mitral valve regurgitation, correlations between 2D Doppler measurements and regurgitant volumes are weaker, possibly because of jet eccentricity.

Animals↗

Finite element analysis of myocardial diastolic function using three-dimensional echocardiographic reconstructions: application of a new method for study of acute ischemia in dogs.

The effect of acute myocardial ischemia on the myocardial elastic modulus has been a matter of controversy. To evaluate this question, diastolic elastic modulus was assessed by finite element analysis of left ventricular geometry using three-dimensional echocardiographic reconstructions and right and left ventricular pressure recordings. Elastic properties were estimated before and after coronary occlusion in 6 open-chest dogs. Elastic modulus values were derived by means of a computer program that determined the global elastic modulus that best predicted the diastolic changes in left ventricular geometry. In the finite element analysis after coronary occlusion, two analyses were performed: one utilizing the control elastic modulus for all segments of the left ventricle and one in which ischemic (dyskinetic) segments were assigned a higher elastic modulus. Results showed that the control elastic modulus was a poor predictor of diastolic left ventricular expansion after coronary occlusion. The finite element analysis in which the ischemic segments were assigned a higher elastic modulus better predicted ischemic diastolic wall motion patterns. Error values (difference between predicted and actual left ventricular segmental diastolic motion) were: control, 1.9 +/- 0.3 mm (mean +/- SD), ischemia, 2.9 +/- 0.5 mm, and 2.2 +/- 0.4 mm using the stiffer elastic modulus for ischemic segments. Error values were significantly higher (p less than 0.05) under ischemic conditions when the control elastic modulus was uniformly applied compared with control and ischemia with dyskinetic segments assigned a higher elastic modulus. From these data, it is concluded that the myocardial diastolic elastic modulus is increased by ischemia and that this approach may allow clinical assessment of intrinsic muscle stiffness.

Animals↗

Effect of wedging on the flow characteristics past tilting disc aortic valve prosthesis.

To evaluate the efficacy of implanting a tilting disc aortic valve prosthesis in an angulated (wedged) supra-annular position, an in vitro experimental study was performed. The aortic valve prosthesis was mounted in an axi-symmetric valve chamber in a wedged position and incorporated in a mock circulatory system. Measurements were obtained on the transvalvular pressure gradient, percent regurgitation as well as velocity profiles and turbulent normal stresses distal to the valve. Our results showed that there was no significant reduction in the pressure gradient in mounting a larger sized valve in the wedged supra-annular position. On the other hand, the percent regurgitation increased with increase in heart rate and wedge angle. The valve failed to function properly above 110 beats min-1 at any wedge angle with the normal flow rate. The velocity profiles also showed significant changes with an increase in the turbulent normal stress with increase in wedge angle. Hence our study suggests that implanting the tilting disc prosthesis in a wedged supra-annular position in the aorta is not advisable.

Aortic Valve↗

Experimental study of physiological pulsatile flow past valve prostheses in a model of human aorta--I. Caged ball valves.

Pulsatile flow development past a caged ball valve in a model human aorta was studied using laser Doppler anemometry. Velocity profiles measured in the ascending aorta and in the mid-arch region were strongly influenced by the geometry of the valve at the root of the aorta. Velocity profiles distal to the valve were asymmetric with jet-like flow in the peripheral region having larger velocity magnitudes towards the left lateral wall. In early diastole, a streamwise vortex motion was observed throughout the model aorta with fluid moving towards the downstream direction along the left lateral wall and reversed flow along the right lateral wall. With the caged ball valve at the root of the aorta, no reversed flow was observed along the inner wall of curvature in the mid-arch region.

Aortic Valve↗

Experimental study of physiological pulsatile flow past valve prosthesis in a model of human aorta--II. Tilting disc valves and the effect of orientation.

In Part II of this two paper sequence, pulsatile flow development past a tilting disc valve in a model human aorta has been studied using quantitative laser Doppler techniques. The valve was mounted in three different orientations with respect to the aortic root in this study. Under pulsatile flow, the region of flow reversal induced near the wall of the minor flow orifice extends to more than one tissue annulus diameter downstream from the valve into the ascending aorta. In a plane perpendicular to the tilt axis, a bi-helical secondary flow is induced distal to the valve. This secondary flow is further compounded by the multiple curvatures in the aorta. Hence the valve orientation affects the velocity profiles as far downstream as the mid-arch region as well as in the brachio-cephalic arterial branch. In the mid-arch region, a flow reversal along the entire cross-section is observed in early diastole for all the three orientations of the disc valve.

Aorta↗

Pulsatile flow past St. Jude Medical bileaflet valve. An in vitro study.

An in vitro hemodynamic study of the St. Jude Medical bileaflet aortic prosthesis was performed in a mock circulatory system simulating physiological pulsatile flow. The study included measurements of pressure drop across the valves, percent regurgitation, velocity, and turbulence in a model human aorta. The measurements indicated that pressure drop (mean systolic pressure drop of 6.2 mm Hg), percent regurgitation (10.15%), and turbulent normal stresses immediately downstream from the valve (825 dynes/cm2) were better than those with other prosthetic valves and bioprostheses. The flow development in the aorta was not significantly affected by the orientation of the bileaflet valve in the root of the aorta. However, velocity measurements immediately downstream from the valves showed flow reversal and separation in the vicinity of the hinge points of the leaflets where thrombus formation has been previously reported.

Aorta↗

Pulsatile flow past aortic valve bioprostheses in a model human aorta.

Pulsatile flow development past tissue valve prostheses in a model human aorta has been studied using qualitative flow visualization and quantitative laser-Doppler techniques. Experiments were conducted both in steady and physiological pulsatile flow situations and the measurements included the pressure drop across the valve, the instantaneous flow rate as well as the velocity profiles and turbulent stresses downstream to the valves. Our study shows that the velocity profiles with pericardial valves are closer to those measured past natural aortic valves. The porcine valves with a smaller valve opening area produce a narrower and stronger jet downstream from the valve with relatively larger turbulent axial stresses in the boundary of the jet. Our study suggests that the pericardial valves with turbulent stresses comparable to those of caged ball and tilting disc valves are preferable from a hemodynamic point of view.

Animals↗

A note on the blood analog for in-vitro testing of heart valve bioprostheses.

Glycerol solution with the viscosity coefficient similar to that of blood is used in evaluating the performance characteristics of prosthetic heart valves in the laboratory. However, physiological saline solution is used as a test fluid in testing tissue heart valves even though the viscosity coefficient does not match that of human blood. It is commonly believed that glycerol is absorbed by the tissue valves and hence the leaflets become stiff, making the test results invalid. However, in our laboratory a comparison of tissue valves exposed to glycerine solution at various times does not indicate any difference in the leaflet opening characteristics. Hence, it is suggested that glycerine solution be used as a test fluid for the evaluation of tissue valves also.

Bioprosthesis↗

Computerized three-dimensional finite element reconstruction of the left ventricle from cross-sectional echocardiograms.

A computerized method for the generation of a three-dimensional finite element mesh of left ventricular geometry is presented. The technique employs two dimensional echocardiographic images of the left ventricle. The echocardiographic transducer is attached to an articulated, computer-assisted, position registration arm with six degrees-of-freedom. These six degrees-of-freedom record the location and orientation of the transducer, when images are obtained, referenced to an external point. Hence, the images are digitized and aligned relative to one another, then several interpolation and curve fitting steps are used to reconstruct a three-dimensional finite element model of the left ventricle. The finite element model can be used for volume determination, stress analysis, material property identification, and other applications.

Computers↗

Laser anemometry measurements of pulsatile flow past aortic valve prostheses.

Experimental results are presented on physiological pulsatile flow past caged ball and tilting disc aortic valve prostheses mounted in an axisymmetric chamber incorporated in a mock circulatory system. The measurements of velocity profiles and turbulent normal stresses during several times in a cardiac cycle were obtained using laser-Doppler anemometry. Our results show that with increased angle of opening for the tilting disc valves, a large but locally confined vortex is observed along the wall in the minor flow region throughout most of the cardiac cycle. The turbulent normal stresses measured downstream to the tilting disc in the minor flow region parallel to the tilt axis were found to be larger than those measured downstream to the caged ball valves. Comparison of measurements with steady flow at flow rates comparable to peak pulsatile flow rate show that the turbulent normal stresses are larger by a factor of two in pulsatile flow with a frequency of 1.2 Hz.

Aortic Valve↗

Steady flow development past valve prostheses in a model human aorta. I. Centrally occluding valves.

In this paper, laser-Doppler anemometry measurement of steady flow development in a model human aorta has been reported. Studies were made with uniform entry flow at the root of the aorta and our measurements showed the establishment of a pair of Dean vortices in the mid-arch region. Subsequently, the nature of flow development past centrally occluding caged ball valves in the model aorta was investigated. Our studies showed that in the ascending aorta, an asymmetric velocity profile is obtained with larger velocity gradients towards the inner wall of tertiary curvature (anatomically the left lateral wall) with centrally occluding valves. The peripheral flow past these valves prevented the development of Dean vortices in the mid-arch region. The caged ball valves at the root of the aorta had no discernible effect on the velocity profiles in the brachio-cephalic artery.

Aorta↗