Popcorn worker's lung: in vitro exposure to diacetyl, an ingredient in microwave popcorn butter flavoring, increases reactivity to methacholine.

Workers who inhale microwave popcorn butter flavorings experience decrements in lung function and can develop clinical bronchiolitis obliterans, i.e., "popcorn worker's lung" (Kreiss, K., Gomaa, A., Kullman, G., Fedan, K., Simoes, E.J., Enright, P.L., 2002. Clinical bronchiolitis obliterans in workers at a microwave-popcorn plant. N. Engl. J. Med. 347, 330-338.). In a rat inhalation model, vapors of an artificial butter flavoring damaged the epithelium of the upper and lower airways (Hubbs, A.F., Battelli, L.A., Goldsmith, W.T., Porter, D.W., Frazer, D., Friend, S., Schwegler-Berry, D., Mercer, R.R., Reynolds, J.S., Grote, A., Castranova, V., Kullman, G., Fedan, J.S., Dowdy, J., Jones, W.G., 2002. Necrosis of nasal and airway epithelium in rats inhaling vapors of artificial butter flavoring. Toxicol. Appl. Pharmacol. 185, 128-135.). Diacetyl, a butter flavoring component, is a major volatile ketone in the popcorn-processing workplace. We investigated the effects of diacetyl on epithelium of guinea pig isolated airway preparations and the effects of diacetyl in vitro on reactivity to bronchoactive agents. In the isolated, perfused trachea preparation, diacetyl added to the intraluminal (mucosal) bath elicited responses that began with contraction (threshold ca. 3 mM) and ended with relaxation. After a 4-h incubation with intraluminal diacetyl (3 mM), contractions to extraluminal (serosal) methacholine (MCh) were slightly increased; however, sensitivity to intraluminally (mucosally) applied MCh was increased by 10-fold. Relaxation responses of MCh (3 x 10(-7) M)-contracted tracheas to extraluminally applied terbutaline and intraluminally applied 120 mM KCl, to evoke epithelium-derived relaxing factor release, were unaffected by diacetyl. Exposure of the tracheal epithelium in Ussing chambers to diacetyl decreased transepithelial potential difference and resistance. These findings suggest that diacetyl exposure compromised epithelial barrier function, leading to hyperreactivity to mucosally applied MCh. The respiratory epithelium appears to serve as an initial target for the toxic effects of diacetyl in the airways.

Animals↗

FEV6 as a surrogate for FVC in detecting airways obstruction and restriction in the workplace.

Compared with measurements of forced vital capacity (FVC), using the forced expiratory volume in six seconds (FEV(6)) reduces test time and frustration. It was hypothesised that using FEV(6) in the workplace setting would result in an acceptably low misclassification rate for detecting airways obstruction and spirometry-defined restriction when compared with using the traditional FVC. Experienced technicians from the National Institute for Occupational Safety and Health performed spirometry using dry rolling-seal spirometers as per American Thoracic Society guidelines in four workplace investigations. Airways obstruction was defined as an FEV(1)/FVC % below the lower limit of normal (LLN) using National Health and Nutrition Examination Survey III reference equations. Restriction was defined as an FVC below the LLN with a normal FEV(1)/FVC %. These "gold standard" definitions were compared with definitions based on FEV(6) (obstruction: FEV(1)/FEV(6) below the LLN; restriction: FEV(6) below the LLN with a normal FEV(1)/FEV(6)). The median (range) age of the 1,139 workers was 37 yrs (18-71 yrs) and 51.4% were male. A significantly high overall agreement was obtained between the two definitions. In conclusion, the current results confirm that forced expiratory volume in six seconds can be used as a surrogate for forced vital capacity in detecting airways obstruction and restriction in workers, although with some misclassification when compared to obtaining American Thoracic Society-acceptable manoeuvres of longer duration.

Adolescent↗

Spirometric reference values from a sample of the general U.S. population.

Spirometric reference values for Caucasians, African-Americans, and Mexican-Americans 8 to 80 yr of age were developed from 7,429 asymptomatic, lifelong nonsmoking participants in the third National Health and Nutrition Examination Survey (NHANES III). Spirometry examinations followed the 1987 American Thoracic Society recommendations, and the quality of the data was continuously monitored and maintained. Caucasian subjects had higher mean FVC and FEV1 values than did Mexican-American and African-American subjects across the entire age range. However, Caucasian and Mexican-American subjects had similar FVC and FEV1 values with respect to height, and African-American subjects had lower values. These differences may be partially due to differences in body build: observed Mexican-Americans were shorter than Caucasian subjects of the same age, and African-Americans on average have a smaller trunk:leg ratio than do Caucasians. Reference values and lower limits of normal were derived using a piecewise polynomial model with age and height as predictors. These reference values encompass a wide age range for three race/ethnic groups and should prove useful for diagnostic and research purposes.