Comparison of results of percutaneous balloon mitral commissurotomy in patients aged > or = 65 years with those in patients aged < 65 years.

Percutaneous balloon mitral commissurotomy (PBMC) is now first-line therapy in patients with symptomatic mitral stenosis (MS) and favorable valve morphology. Unfortunately, the outcome of Medicare-aged patients undergoing this procedure has not previously been defined. The results of PBMC in 55 patients > or = 65 years old (71 +/- 6 years) with moderate or severe MS were compared with 268 younger patients (47 +/- 10). Preprocedural New York Heart Association functional class and pulmonary pressures did not differ. The older patients had higher blood pressure, were more likely to be in atrial fibrillation and had higher valve scores (9.9 +/- 2.5 vs 8.6 +/- 2.2, p = 0.001). Procedural success was higher in the younger group (71% vs 55%, p = 0.013), with a greater increase in mitral valve area. Complications were similar in both groups and there were no periprocedural deaths. At 6 months a significant improvement in function class was seen in both groups. Restenosis, as assessed by serial echocardiography, occurred at a rate of 0.06 cm(2)/year in both groups, and functional class remained unchanged over 3 years. Event-free survival was similar at 48 months: 76% in the younger group and 69% in the older group. Our data thus demonstrates that PBMC can be safely performed in the Medicare-aged population. Despite less acute success in the older population, complication rates do not differ and decrement in valve area over time occurs at a similar rate. Functional class remains improved and event-free survival over 4 years appears similar in both groups. PBMC should thus be offered to patients with MS and suitable anatomy regardless of their age.

Adult↗

Assessing the severity of mitral stenosis: variability between noninvasive and invasive measurements in patients with symptomatic mitral valve stenosis.

BACKGROUND: This study evaluated the correlation and variability between noninvasive and invasive measures of mitral stenosis severity before and after balloon mitral commissurotomy (BMC) in a large group of patients with symptomatic mitral stenosis. Factors related to variability between measurements were determined. METHODS: The Doppler transmitral gradient, Doppler half-time valve area, and 2-dimensional echocardiographic (2D) mitral valve area (MVA) were measured immediately before and 1 day after BMC in 272 consecutive patients with mitral stenosis and compared with their respective measures during cardiac catheterization. RESULTS: The correlation coefficient for the comparison of noninvasive and invasive measurements of the transmitral gradient was 0.63 before BMC and 0.60 after the procedure; for 2D versus Gorlin-derived MVA, 0.39 and 0.57, respectively; and for Doppler half-time versus Gorlin-derived MVA, 0.31 and 0.18, respectively. A large degree of variability in the measurement of MVA was present among the 3 techniques before BMC and increased after BMC. Before BMC, for the comparison of 2D and Gorlin-derived MVA, variables predictive of the discrepancy were age, echocardiographic score, transmitral gradient during catheterization, and cardiac index. For the comparison of Doppler half-time versus Gorlin-derived MVA, age, heart rate during cardiac catheterization and echocardiography, cardiac output and left ventricular end-diastolic pressure predicted the difference between the 2 measures. CONCLUSIONS: In symptomatic patients with mitral stenosis, there is significant variability between noninvasive and invasive measures of mitral stenosis severity despite careful, reproducible measurements. The difference between noninvasive and invasive measures of MVA before BMC is strongly related to cardiac output.

Cardiac Catheterization↗

What does the left atrial v wave signify during balloon commissurotomy of mitral stenosis?

Left atrial v-wave amplitude has been associated with the presence and severity of chronic mitral regurgitation (MR) but it has not been evaluated for the detection of acute MR. We evaluated the left atrial v-wave amplitude of 205 consecutive patients with mitral stenosis immediately before and after stepwise, incremental balloon mitral commissurotomy to determine predictors of large v waves at baseline and an increase in v-wave amplitude after balloon commissurotomy. The sensitivity and specificity of an increase in v-wave amplitude for detecting worsening and severe MR were determined. A large v wave was present in 44% of patients before balloon commissurotomy and was predicted by age, mean left atrial pressure, mean transmitral gradient, mean pulmonary artery pressure, and angiographic severity of MR. There was a strong inverse correlation between v-wave amplitude and calculated left atrial compliance (r = -0.92). An increase in v-wave amplitude after balloon commissurotomy was associated with an increasing probability of worsening or severe MR. This indicator had a sensitivity, specificity, and positive and negative predictive values of 35%, 91%, 64%, 75%, respectively, for detecting any increase in MR. For the detection of severe MR, the sensitivity was 79%, specificity 89%, positive predictive value 42%, and negative predictive value 98%. Thus, left atrial v-wave amplitude reflects left atrial compliance and severity of mitral stenosis before balloon commissurotomy. An increase in v-wave amplitude is an insensitive but very specific indicator of worsening or severe MR during stepwise, incremental balloon mitral commissurotomy.

Atrial Function, Left↗

Doppler pressure half-time method of assessing mitral valve area: aortic insufficiency does not adversely affect validity.

OBJECTIVES: This study evaluated the effect of aortic insufficiency on the correlation of pressure half-time-derived mitral valve area with each of 2 standards for mitral valve area (planimetry and cardiac catheterization) in a prospectively assembled cohort of patients scheduled for percutaneous balloon mitral commissurotomy. BACKGROUND: Although Doppler pressure half-time has been validated as a method for assessing mitral valve area, most previous studies have suggested that this noninvasive technique overestimates mitral valve area in the setting of coexistent aortic insufficiency. METHODS AND RESULTS: Echocardiography and cardiac catheterization were performed on 212 consecutive patients scheduled for percutaneous balloon mitral commissurotomy. After excluding 35 patients who did not have aortography, the rest were divided into a "no aortic insufficiency [AI] group" (n = 146) including those with trivial or no aortic insufficiency at catheterization and an "AI group" (n = 31 ) including those with mild or moderate aortic insufficiency. The pressure half-time mitral valve area tended to slightly underestimate invasive valve area by 0.04 cm2 in the AI group and to slightly overestimate invasive valve area by 0.06 cm2 in the no AI group. This difference between the groups was not statistically significant (P = .13). The pressure half-time mitral valve area tended to underestimate planimetered valve area by 0.11 cm2 in the AI group and by 0.10 cm2 in the no AI group. There was no difference between the 2 groups (P = .94). Potential confounders that could theoretically mask the effect of aortic insufficiency on the pressure half-time (including age, heart rate, blood pressure, left ventricular diastolic pressure, ejection fraction, mitral regurgitation, and atrial fibrillation) were excluded by multivariable analyses. CONCLUSIONS: The pressure half-time method of determining mitral valve area is not adversely affected by mild to moderate aortic insufficiency. This finding has implications for the utility of this technique in the rheumatic valvular disease population, in which mitral and aortic valve disease frequently coexist.

Adult↗

Effect of inadequate cardiac output reserve on exercise tolerance in patients with moderate mitral stenosis.

Twenty-nine patients with moderate mitral stenosis and 29 age-matched normal controls underwent symptom-limited upright bicycle exercise testing with simultaneous hemodynamic monitoring. Exercise tolerance in the mitral stenosis group was found to be limited by inadequate cardiac output reserve and not by resting mitral valve area or exercise pulmonary capillary wedge pressure.

Adult↗

Balloon aortic valvuloplasty in adults: failure of procedure to improve long-term survival.

OBJECTIVES: This study sought to determine the long-term outcome of adult patients undergoing percutaneous balloon aortic valvuloplasty. BACKGROUND: Percutaneous balloon aortic valvuloplasty has been offered as an alternative to aortic valve replacement for selected patients with valvular aortic stenosis. Although balloon aortic valvuloplasty produces an immediate reduction in the transvalvular aortic gradient, a high incidence of restenosis frequently leads to recurrent symptoms. Therefore, it is unclear whether balloon aortic valvuloplasty impacts on the long-term outcome of these patients. METHODS: Clinical, hemodynamic and echocardiographic data were collected at baseline in 165 patients undergoing balloon aortic valvuloplasty and examined for their ability to predict long-term outcome. RESULTS: The median duration follow-up was 3.9 years (range 1 to 6). Ninety-nine percent follow-up was achieved. During this 6-year period, 152 patients (93%) died or underwent aortic valve replacement, and 99 (60%) died of cardiac-related causes. The probability of event-free survival (freedom from death, aortic valve replacement or repeat balloon aortic valvuloplasty) 1, 2 and 3 years after valvuloplasty was 40%, 19% and 6%, respectively. In contrast, the probability of survival 3 years after balloon aortic valvuloplasty in a subset of 42 patients who underwent subsequent aortic valve replacement was 84%. Survival after aortic valvuloplasty was poor regardless of the presenting symptom, but patients with New York Heart Association functional class IV congestive heart failure had events earliest. Univariable predictors of decreased event-free survival were younger age, advanced congestive heart failure symptoms, lower ejection fraction, elevated left ventricular end-diastolic pressure, presence of coronary artery disease and increased left ventricular internal diastolic diameter. Stepwise multivariable logistic regression analysis found that only younger age and a lower left ventricular ejection fraction contributed independent adverse prognostic information (chi-square 14.89, p = 0.0006). CONCLUSIONS: Long-term event-free and actuarial survival after balloon aortic valvuloplasty is dismal and resembles the natural history of untreated aortic stenosis. Aortic valve replacement may be performed in selected subjects with good results. However, the prognosis for the remainder of patients who are not candidates for aortic valve replacement is particularly poor.

Aged↗

Left ventricular performance improves late after aortic valve replacement in patients with aortic stenosis and reduced ejection fraction.

EF in patients with aortic stenosis and reduced EF who underwent aortic valve replacement did not improve by 1 week postoperatively despite rectification of afterload mismatch. By 6 months, however, EF significantly improved without any further change in ventricular loading conditions. This implies that the benefit from aortic valve replacement (when measured by LV ejection performance) may not be evident until late postoperatively.

Aged↗

Transesophageal echocardiographic assessment of reversal of systolic pulmonary venous flow in mitral stenosis.

Transesophageal echocardiography and diagnostic cardiac catheterization were performed in 36 patients with symptomatic mitral stenosis to assess the incidence and significance of systolic flow reversal in the pulmonary veins. Mitral regurgitation was graded by contrast ventriculography, and left atrial pressure was directly measured after transseptal puncture. Pulmonary venous flow was recorded with transesophageal Doppler imaging from the left upper pulmonary vein. Early systolic flow reversal was identified in 11 patients (31%) and began an average of 58 +/- 13 ms after QRS onset. This pattern correlated strongly with the presence of atrial fibrillation or flutter. Late systolic flow reversal was identified in 8 patients (22%), beginning an average of 245 +/- 46 ms after the QRS complex. These patients had higher left atrial V-wave pressure (36 +/- 10 vs 29 +/- 8 mm Hg; p < 0.05) and V-wave peak-X-descent trough (18 +/- 7 vs 11 +/- 5 mm Hg; p < 0.01) than patients without systolic flow reversal. Neither pattern of pulmonary venous flow reversal was related to the severity of angiographic mitral regurgitation. Systolic reversal of pulmonary venous flow is not specific for angiographically severe mitral regurgitation in patients with mitral stenosis. Similar limitations to pulmonary venous flow analysis likely apply to other patient groups with elevated left atrial pressure and poor left atrial compliance.

Adult↗

Intravascular ultrasound in the management of acute coronary artery dissection: a case report.

Crossing total occlusions is frequently difficult. The guidewire may enter a false lumen, thereby preventing successful balloon dilatations. We present a case of an acute arterial dissection following attempted angioplasty of a totally occluded right coronary artery. With an intravascular ultrasound probe in the false lumen, we were able to visualize a second guidewire and direct its passage into the true arterial lumen. This allowed for successful balloon dilatation and stent deployment restoring vessel patency.

Aortic Dissection↗

Rapid visualization of massive pulmonary emboli utilizing intravascular ultrasound.

Massive pulmonary embolism may result in rapid deterioration prior to diagnostic and therapeutic intervention. Intravascular ultrasound imaging has been utilized previously to evaluate vascular abnormalities as well as normal human pulmonary arteries. We employed this technique to rapidly identify massive pulmonary emboli located in the main pulmonary arteries of two patients. The presence of these emboli was confirmed with pulmonary arteriography. Intravascular ultrasound may be utilized to rapidly confirm the presence of large proximal pulmonary emboli.

Aged↗

Relief of superior vena cava syndrome due to fibrosing mediastinitis using the Palmaz stent.

Relief of superior vena cava (SVC) syndrome due to non-neoplastic mediastinal disease presents a formidable challenge. Long-term patency of surgically created bypass grafts has been poor, and the morbidity associated with these procedures is substantial. We report a case of SVC syndrome, caused by fibrosing mediastinitis, treated with Palmaz balloon expandable intravascular stents. Intravascular stents are a promising alternative for relief of non-neoplastic SVC obstruction.

Adult↗

Aortic valve replacement in adults after balloon aortic valvuloplasty.

BACKGROUND: Percutaneous balloon aortic valvuloplasty is limited by a high risk of procedural morbidity, transient clinical benefit, and a high restenosis rate. The management of patients with symptomatic aortic valve restenosis after percutaneous balloon aortic valvuloplasty is unclear. We hypothesized that aortic valve replacement would produce superior midterm survival compared with repeat balloon aortic valvuloplasty or medication alone in patients with symptomatic aortic valve restenosis after prior balloon aortic valvuloplasty. METHODS AND RESULTS: Baseline clinical, echocardiographic, and hemodynamic data were collected on 165 patients who underwent percutaneous balloon aortic valvuloplasty as treatment for symptomatic degenerative calcific aortic stenosis. In 144 of these patients (87%), aortic valve replacement was originally considered to carry excessive risk. The survival of three subgroups was calculated during a median follow-up period of 3.9 years (range, 1 to 6 years). Ninety-four patients (57%) had no further mechanical intervention (subgroup 1-BAV), 31 patients (19%) developed symptomatic aortic valve restenosis and underwent a repeat balloon aortic valvuloplasty (subgroup 2-BAV), and 40 patients (24%) subsequently underwent aortic valve replacement (subgroup BAV+AVR). Follow-up was 99% complete. Patients in subgroup BAV+AVR tended to be younger and have a lower prevalence of coronary artery disease or mitral regurgitation. Only 1 patient (2.5%) suffered a perioperative death during aortic valve replacement. The probability of survival 3 years from the date of the last mechanical intervention was 13% for subgroup 1-BAV, 20% for subgroup 2-BAV, and 75% for subgroup BAV+AVR. At the conclusion of follow-up, only 2 patients had symptoms of congestive heart failure or angina after aortic valve replacement. CONCLUSIONS: Aortic valve replacement may be performed with a low mortality rate, excellent palliation of symptoms, and prolongation of survival in selected high-risk patients with a history of previous balloon aortic valvuloplasty.

Actuarial Analysis↗

In vivo validation of compensatory enlargement of atherosclerotic coronary arteries.

Necropsy examinations and epicardial ultrasound studies have suggested that atherosclerotic coronary arteries undergo compensatory enlargement. This increase in vessel size may be an important mechanism for maintaining myocardial blood flow. It also is of fundamental importance in the angiographic study of coronary disease progression and regression. The purpose of this study was to determine, using intracoronary ultrasound, whether coronary arteries undergo adaptive expansion in vivo. Forty-four consecutive patients were studied (30 men, 14 women; mean age 56 +/- 10 years). Eighty intravascular ultrasound images were analyzed (32 left main, 23 left anterior descending and 25 right coronary arteries). Internal elastic lamina area, a measure of overall vessel size increased as plaque area expanded (r = 0.57, p = 0.0001, SEE = 5.5 mm2). When the left main, left anterior descending and right coronary arteries were examined individually, there continued to be as great or greater positive correlation between internal elastic lamina and plaque area (left anterior descending: r = 0.75, p = 0.0001; right coronary arteries: r = 0.63, p = 0.0007; left main: r = 0.56, p = 0.0009), implying that each of the vessels and all in aggregate underwent adaptive enlargement. When only those vessels with < 30% area stenosis were examined, internal elastic lamina correlated well with plaque area (r = 0.79, and p = 0.0001), and for each 1 mm2 increase in plaque area, internal elastic lamina increased 2.7 mm2. This suggests that arterial enlargement may overcompensate for early atherosclerotic lesions.(ABSTRACT TRUNCATED AT 250 WORDS)

Adaptation, Physiological↗

Unrecognized left main coronary artery disease in patients undergoing interventional procedures.

Selective, coronary arteriographic, catheter-based, intravascular ultrasound images were obtained to determine the presence and extent of angiographically undetected or underestimated left main (LM) coronary arterial narrowing in patients receiving coronary interventional therapy. Coronary arteriograms were determined to be either normal or abnormal by visual inspection. Abnormal arteriograms were digitized and quantitated using a semiautomated edge-detection algorithm. Thirty-eight patients receiving percutaneous treatment of stenoses in the left coronary artery system were studied. Optimal LM coronary angiograms were obtained in 2 views, and intravascular ultrasound images were obtained after the coronary interventional procedure. Intravascular ultrasound detected plaque in 24 of 27 angiographically normal LM arteries (89%), whereas narrowing was observed in 11 of 11 angiographically abnormal LM arteries (100%). Eight of 38 patients (21%) had > 40% area stenosis by intravascular ultrasound. In patients with angiographic disease, there was no correlation between quantitative angiographic and ultrasound percent area stenosis (r = 0.12; p = 0.72; SEE 19%). The median plaque area was not different between angiographically normal (0.05 cm2; 0.03, 0.08 [25th, 75th percentile]) and abnormal (0.06 cm2; 0.03, 0.1) patients. The median percent area stenosis in arteriographically normal subjects (26%; 14, 32%) was less than that in abnormal ones (37%; 20, 46%) (p = 0.03). Unrecognized LM disease is widespread and often underestimated in patients with normal LM angiograms undergoing interventional procedures. Plaque area is similar for angiographically normal and insignificantly abnormal vessels. This study suggests that intravascular ultrasound overcomes the limitations of silhouette imaging and can be a clinically useful, adjunctive method to evaluate LM coronary artery disease.

Algorithms↗

Intracoronary ultrasound predictors of adverse outcomes after coronary artery interventions.

OBJECTIVES: The purpose of this study was to determine the association between qualitative and quantitative lesion characteristics as assessed by intracoronary ultrasound imaging and adverse outcomes after coronary artery interventions. BACKGROUND: Restenosis and other adverse outcomes after coronary artery interventions may be difficult to predict from clinical or angiographic data. Intracoronary ultrasound imaging provides additional data that could prove useful. METHODS: Immediately after successful coronary artery interventions (angiographic residual stenosis < or = 50%), 69 patients underwent intracoronary ultrasound imaging. Images were assessed qualitatively for plaque composition and topography and for dissection. Quantitative data included measurement of minimal lumen diameter, lumen area, plaque area and percent area stenosis at the treatment and adjacent reference sites. Adverse outcome was defined as death, coronary bypass surgery, myocardial infarction or angiographic restenosis. RESULTS: Of the 69 patients, 1 died, 3 had bypass surgery and 1 had a myocardial infarction before planned 6-month repeat catheterization. Two patients were lost to follow-up study. Of the remaining 62 patients, 56 (90%) agreed to follow-up catheterization and 25 (45%) of the 56 had restenosis. Thus, 30 patients had an adverse outcome and 37 had no adverse event. The incidence of dissection detected by ultrasound imaging after an intervention was significantly greater in patients with than in those without a subsequent adverse event (63% vs. 35%, p < 0.05). The severity of dissection also appeared to be related to outcome (p < 0.05). Other qualitative and quantitative variables were not significantly different between the two patient groups. CONCLUSIONS: Dissection, as assessed by intracoronary ultrasound imaging after a coronary artery intervention, can identify patients at increased risk of subsequent adverse events. Additional studies are warranted to explore whether such imaging may allow modification of interventional procedures to improve outcome.

Angioplasty, Balloon, Coronary↗

Left ventricular filling and ventricular diastolic performance after percutaneous balloon mitral valvotomy.

The time course of left ventricular (LV) filling and LV diastolic performance were examined in 27 consecutive patients in sinus rhythm before and acutely after balloon mitral valvotomy (BMV). The mitral valve area acutely increased from 1.1 +/- 0.3 to 2.1 +/- 0.8 cm2. Simultaneous pressure-volume data were obtained using digital subtraction left ventriculography and LV micromanometer pressure before and 10 minutes after BMV. The time constant of LV isovolumic relaxation was unchanged after BMV (50 +/- 10 ms before BMV vs 47 +/- 13 ms after BMV). In addition, values before and after BMV for LV end-diastolic volume (123 +/- 29 vs 125 +/- 36 ml), end-diastolic pressure (11 +/- 4 vs 12 +/- 4 mm Hg) and diastolic filling time (337 +/- 126 vs 338 +/- 152 ms) were not altered by the procedure. After BMV the peak diastolic filling rate (403 +/- 143 vs 469 +/- 302 ml/s) was maintained despite a 36% reduction in left atrial filling pressure. There was a trend toward earlier occurrence of the peak filling rate (196 +/- 127 vs 146 +/- 148 ms, p = 0.08). The percentage of diastolic filling in the first third of diastole, however, was similar (42 +/- 9 vs 48 +/- 16%) before and after the procedure. Thus, the time course of LV filling is not significantly altered acutely after BMV, but is maintained at reduced left atrial filling pressure. Neither LV relaxation or LV chamber compliance are altered acutely after BMV.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗