PubMed Health⌕ Search

Biomedical subjects

K B Tomer

Publications and source records attributed to K B Tomer.

At least 73 records · Page 4Linked to original sources

Radical adducts of nitrosobenzene and 2-methyl-2-nitrosopropane with 12,13-epoxylinoleic acid radical, 12,13-epoxylinolenic acid radical and 14,15-epoxyarachidonic acid radical. Identification by h.p.l.c.-e.p.r. and liquid chromatography-thermospray-m.s.

Linoleic acid-derived radicals, which are formed in the reaction of linoleic acid with soybean lipoxygenase, were trapped with nitrosobenzene and the resulting radical adducts were analysed by h.p.l.c.-e.p.r. and liquid chromatography-thermospray-m.s. Three nitrosobenzene radical adducts (peaks I, II and III) were detected; these gave the following parent ion masses: 402 for peak I, 402 for peak II, and 386 for peak III. The masses of peaks I and II correspond to the linoleic acid radicals with one more oxygen atom [L(O).]. The radicals are probably carbon-centred, because the use of 17O2 did not result in an additional hyperfine splitting. Computer simulation of the peak I radical adduct e.p.r. spectrum also suggested that the radical is carbon-centred. The peak I radical was also detected in the reaction of 13-hydroperoxylinoleic acid with FeSO4. From the above results, peak I is probably the 12,13-epoxylinoleic acid radical. An h.p.l.c.-e.p.r. experiment using [9,10,12,13-2H4]linoleic acid suggested that the 12,13-epoxylinoleic acid radical is a C-9-centred radical. Peak II is possibly an isomer of peak I. Peak III, which was observed in the reaction mixture without soybean lipoxygenase, corresponds to a linoleic acid radical (L.). The 12,13-epoxylinoleic acid radical, 12,13-epoxylinolenic acid radical and 14,15-epoxyarachidonic acid radical were also detected in the reactions of linoleic acid, linolenic acid and arachidonic acid respectively, with soybean lipoxygenase using nitrosobenzene and 2-methyl-2-nitrosopropane as spin-trapping agents.

Chromatography, High Pressure Liquid↗

Isolation and identification of alpha-(4-pyridyl-1-oxide)-N-tert-butylnitrone radical adducts formed by the decomposition of the hydroperoxides of linoleic acid, linolenic acid, and arachidonic acid by soybean lipoxygenase.

alpha-(4-Pyridyl-1-oxide)-N-tert-butylnitrone (4-POBN) radical adducts, which are formed in the reactions of soybean lipoxygenase with linoleic acid, arachidonic acid, and linolenic acid, were isolated using HPLC-ESR spectroscopy. Both linoleic acid and arachidonic acid gave one radical adduct, whereas in the case of linolenic acid, two radical adducts were isolated. These radical adducts all showed virtually identical uv spectra with lambda max at 292 and 220 nm in hexane. The absence of absorbance with lambda max at 234 nm indicates that a conjugated diene structure is not contained in these radical adducts. The mass spectra of the radical adducts formed from linoleic and arachidonic acids were identical and contained a molecular ion of m/z 264, consistent with the trapping of the pentyl radical by 4-POBN. Indeed, authentic 4-POBN pentyl radical adduct obtained from the reaction between pentylhydrazine and 4-POBN gave the same mass spectrum as the product obtained from the reaction of linoleic acid and arachidonic acid with 4-POBN. The two 4-POBN radical adducts formed in the linolenic acid reaction were shown by mass spectrometry to be isomers of pentenyl radicals. The 4-POBN-pentyl radical adduct was also detected in the reaction mixture of 13-hydroperoxy-linoleic acid, soybean lipoxygenase, and 4-POBN, indicating that the pentyl radical and pentenyl radical are formed by the decomposition of the hydroperoxides.

Arachidonic Acids↗

Determination of bioactive peptides using capillary zone electrophoresis/mass spectrometry.

Mixtures of bioactive peptides have been analyzed by capillary zone electrophoresis/mass spectrometry (CZE/MS) using an on-line coaxial continuous-flow fast atom bombardment interface. High separation efficiencies (up to 410,000 theoretical plates) were obtained from low femtomole levels of peptides. The analysis of basic peptides was accomplished by using aminopropyl-silylated CZE columns to minimize zone broadening due to adsorption effects. CZE/MS/MS data were acquired from femtomole levels of peptides in electrophoretic real time.

Absorption↗

The application of hybrid mass spectrometry/mass spectrometry and high-resolution mass spectrometry to the analysis of fish samples for polychlorinated dibenzo-p-dioxins and dibenzofurans.

A hybrid mass spectrometer operated in low-resolution selected decomposition monitoring (SDM) mode was used for the analysis of whole fish samples for the 2,3,7,8-substituted polychlorinated dibenzo-p-dioxins and poly-chlorinated dibenzofurans (PCDD/Fs). These fish samples were previously analyzed for PCDD/Fs using a high-resolution mass spectrometer following EPA protocols. The hybrid tandem mass spectrometric method using loss of COCl gave similar quantification results to those obtained by high-resolution mass spectrometry and eliminated the interferences attributed to polychlorinated biphenyls that were encountered in the high-resolution mass spectrometric analysis. Comparison of the two methods shows that the high-resolution mass spectrometric method surpasses the tandem mass spectrometric method in other analytical figures of merit, such as detection limit, linearity and reproducibility.

Animals↗

Coaxial continuous flow fast atom bombardment for higher-molecular-weight peptides: comparison with static fast atom bombardment and electrospray ionization.

A comparison of coaxial continuous flow fast atom bombardment (FAB) with static FAB and with electrospray ionization (ESI) for the analysis of 'high'-mass peptides (Mr = 3000-4000) is presented. Sensitivities of the peptides by coaxial continuous flow FAB is nearly an order of magnitude better than by static FAB. Single-scan spectra with good signal-to-noise can be obtained from as little as 200 fmol (by flow injection analysis). Detection limits by ESI mass spectrometry were found to be equivalent to 20 times higher than by coaxial continuous flow FAB on a per mole basis, but 4-20 times lower on a concentration basis, owing to the greater flow per unit time employed in the ESI mass spectrometric experiments.

Mass Spectrometry↗

Capillary zone electrophoresis-mass spectrometry using a coaxial continuous-flow fast atom bombardment interface.

Mixtures of peptides have been analyzed by capillary zone electrophoresis in conjunction with mass spectrometry (MS) using an on-line coaxial continuous-flow fast atom bombardment interface. MS and MS-MS spectra have been acquired in electrophoretic real time from femtomole levels of the peptides, while maintaining separation efficiencies in excess of 100,000 theoretical plates.

Amino Acids↗

Determination of Senecio alkaloids by thermospray liquid chromatography/mass spectrometry.

A series of Senecio alkaloid and alkaloid N-oxide standards has been analyzed using positive and negative ion thermospray liquid chromatography/mass spectrometry (LC/MS) with an ammonium acetate-containing mobile phase. On-line separations of pyrrolizidine alkaloids from extracts of Senecio jacobaea (tansy ragwort) and Senecio vulgaris (common groundsel) were done using an ammonium hydroxide-containing mobile phase. All of the alkaloids known to be present in the extracts were detected by ammonium hydroxide thermospray LC/MS, as well as many other components which may be as-yet-unidentified alkaloids.

Acetates↗

Gas chromatography/electron impact mass spectrometry, fast atom bombardment mass spectrometry, mass-analyzed ion kinetic energy spectroscopy and B/E linked scan analysis of triaryl phosphates and triethylene glycol fatty acid esters.

Tris(isopropylphenyl/phenyl) phosphates and triethylene glycol dicaprate/caprylate mixtures of typical industrial compositions have been analyzed by fast atom bombardment (FAB) mass spectrometry, FAB collisional activation (CA) mass-analyzed ion kinetic energy spectroscopy and FAB/electron impact (EI) CA B/E linked scans. Data obtained by these state-of-the-art methodologies are compared qualitatively and semi-quantitatively with those provided by classical gas chromatography (GC)/EI MS. To identify the plasticizers in cases of suspected contamination, GC/EI MS still appears to be the method of choice whenever ultimate sensitivity and specificity are needed. In cases where these requirements are less demanding, FAB mass spectrometry and FAB tandem mass spectrometry may be sufficient and more convenient.

Chemical Phenomena↗

Radical identification by liquid chromatography/thermospray mass spectrometry.

Radical adducts of 5,5-dimethyl-1-pyrroline N-oxide (DMPO) with hydroxyl, methanol-derived, and ethanol-derived radicals were detected by a combination of liquid chromatography with either electron paramagnetic resonance or thermospray mass spectrometry (LC/EPR or LC/TSP-MS) in the Fenton system (with methanol or ethanol). One radical adduct was observed in the reaction of DMPO with the hydroxyl radical or the methanol-derived radical, while two adducts were detected in the reaction of DMPO with ethanol-derived radicals. The LC/TSP-MS spectra showed quasi-molecular ions [M + H]+ at m/z 146 and m/z 160 for the methanol-derived and ethanol-derived radical adducts, respectively, and an apparent molecular ion M+ at m/z 130 for the hydroxyl radical adduct. Use of methyl-D3 alcohol (CD3OH) and ethyl-D5 alcohol (CD3CD2OH) indicated that carbon-centered radicals are formed. Experiments with partially deuterated ethanol (CD3CH2OH and CH3CD2OH) indicated that the two adducts observed in the reaction of DMPO with ethanol-derived radicals correspond to the two diastereomeric adducts of DMPO with the alpha-hydroxyethyl free radical.

Chromatography, Liquid↗

Metabolism of metolachlor by a microsomal fraction isolated from grain sorghum (Sorghum bicolor) shoots.

A microsomal fraction isolated from the shoots of 3- to 4-day-old, dark-grown, grain sorghum (Sorghum bicolor cv. Funk G 522 DR) seedlings was characterized. The preparations had a cytochrome P-450 content that varied from approximately 90 to 150 pmol P-450/mg protein with cytochrome P-420 varying from 0 to 3% of the P-450 content. Type I difference spectra were formed with cinnamic acid and metolachlor, and a type II spectrum was formed with tetcyclacis. In short-term assays with [14C]metolachlor as substrate, the preparations produced a single time-dependent product that separated on silica gel TLC plates developed in benzene/acetone (2:1, v/v). RF values for metolachlor and the metabolite were approximately 0.70 and 0.48, respectively. The microsomal reaction required NADPH and oxygen, and was inhibited by carbon monoxide, with the inhibition being partially reversed by actinic light. Compounds known to inhibit the activity of cytochrome P-450 monooxygenases (piperonyl butoxide, tetcyclacis, and tridiphane) also prevented formation of the metabolite. Identity of the metabolite was confirmed by TLC and positive ion thermospray LC/MS to be 2-chloro-N-(2-ethyl-6-methylphenyl)-N-(2-hydroxy-1-methylethyl)acetamide . Hence, the reaction catalyzed by the sorghum microsomes involved O-demethylation of the methoxypropyl side chain of metolachlor.

Acetamides↗

Fast atom bombardment and tandem mass spectrometry for structure determination of cysteine, N-acetylcysteine, and glutathione adducts of xenobiotics.

Fast atom bombardment mass spectrometry (FAB/MS) and FAB combined with tandem mass spectrometry (MS/MS) were examined for their applicability to the structure determination of xenobiotics conjugated with the members of the glutathione family (glutathione, cysteine, and N-acetylcysteine). Comparisons between FAB/MS and thermospray MS data are made. FAB/MS is generally successful at generating molecular ion species under both positive and negative ion conditions. Upon collisional activation the adducts undergo characteristic cleavages around the sulfur providing structural information about the conjugate. The analysis of the N-acetylcysteine conjugate isolated from rat urine is presented as an example of the application of FAB/MS/MS to biological problems.

Acetylcysteine↗

Coaxial continuous flow fast atom bombardment in conjunction with tandem mass spectrometry for the analysis of biomolecules.

The capability of interfacing coaxial continuous flow fast atom bombardment (CF-FAB) with tandem mass spectrometry (MS/MS) is demonstrated. The goal of this research is to demonstrate the ability of obtaining on-the-fly (i.e. chromatographic real time) MS/MS spectra of biomolecules and to demonstrate the feasibility of using open tubular CF-FAB as a means of introducing and maintaining a constant flux of analyte into the mass spectrometer over long periods of time. On-the-fly MS/MS spectra of a tripeptide, Met-Leu-Phe, were obtained on a 220-pg injection and a 22-pg injection. With a total acquisition time of 2 s, fragment ions resulting from common backbone cleavages were observed. With a 50 microns i.d. packed microcapillary column, the separation of a mixture was obtained and the MS/MS spectra were acquired as the analytes were eluting from the column. Through the use of the coaxial CF-FAB interface to deliver a constant flow of analyte, MS/MS spectra of a variety of compounds, including peptides, sugars, fatty acids, phospholipids, and steroids, were obtained as well as an MS/MS/MS spectrum of a tetrapeptide.

Carbohydrates↗

Bradykinin and kininogens in bovine milk.

Two peptides exhibiting kinin activity in an isolated rat uterus assay were purified from pasteurized skim bovine milk. The amino acid sequence of the more prominent peptide was found to be that of bradykinin. Partially purified kinin preparations were also obtained from N-tosyl-L-phenylalanyl chloromethyl ketone-treated trypsin digests of non-fat dry milk and insoluble lactalbumin. The application of fast atom bombardment/mass spectrometry permitted detection of the bradykinin protonated molecular ion in each of these samples. Collision-activated decomposition of the ion of m/z 1061 confirmed it to be the protonated molecular ion of bradykinin. Fast atom bombardment/mass spectrometry analysis further confirmed the occurrence of bradykinin in a pancreatic kallikrein digest of a partially purified bovine milk kininogen preparation. In apparent contrast with bovine plasma kininogens, the forms of kininogen which occur in milk include a high Mr kininogen (Mr greater than 68,000) and a low Mr kininogen (Mr 16,000-17,000). Kinin formation from the high Mr kininogen is catalyzed by porcine pancreatic kallikrein or trypsin.

Animals↗

Coupling of capillary zone electrophoresis and capillary liquid chromatography with coaxial continuous-flow fast atom bombardment tandem sector mass spectrometry.

The coaxial continuous-flow fast atom bombardment (FAB) system has proven to be very useful for interfacing capillary liquid chromatography and capillary zone electrophoresis (CZE) with sector mass spectrometry (MS). The interface can be used for the acquisition of both MS and MS-MS spectra from femtomole levels of non-volatile and/or thermally labile analytes while maintaining separation efficiencies of hundreds of thousands of plates. The use of coaxial fused-silica capillary columns to independently deliver the microcolumn effluent and the FAB matrix to the tip of the FAB probe offers the following advantages: the composition and flow-rates of the two liquid streams can be independently optimized; the FAB matrix does not effect the microcolumn separation process; peak broadening is minimized since the two liquid streams do not mix until they reach the tip of the FAB probe where ion desorption occurs; and, with CZE, active electrophoretic transport delivers the analytes directly to the FAB probe tip. These features combine to make this coaxial continuous flow fast atom bombardment interface particularly well suited for use with microcolumn separation methods.

Chromatography, Liquid↗

Biochemical applications of liquid chromatography-mass spectrometry.

The current state-of-the-art liquid chromatography-mass spectrometry (LC-MS) is reviewed with particular attention to biomedical applications. The most common LC-MS interface designs are described and compared. These interfaces include transport, direct liquid introduction, thermospray, atmospheric pressure ionization, monodisperse aerosol generation, open-tubular LC and continuous-flow fast atom bombardment. The relative sensitivities of the techniques are compared as much as possible, as well as their tendencies to induce thermal decomposition of the sample. Applications of these various interface types to a variety of biomedically important compound classes, including peptides, nucleotides, steroids, lipids, carbohydrates, xenobiotic metabolites and drugs, are also reviewed.

Biochemistry↗

12S,19- and 12S,20-dihydroxyeicosanoids: novel 12S-hydroxy-5,8-cis-10-trans-14-cis-eicosatetraenoic acid metabolites formed by hydroxylation and reduction in murine lymphocytes.

Murine spleen cells and purified B lymphocytes oxidized arachidonic acid via the lipoxygenase pathway. The major metabolite of both the whole spleen and enriched B lymphocytes was 12S-hydroxy-5,8-cis-10-trans-14-cis-eicosatetraenoic acid. A novel metabolite was observed that did not have an absorbance from 210 to 400 nm, indicating the absence of a conjugated double bond system. The new metabolite was converted to the methyl ester, reduced by platinum oxide, derivatized to the trimethylsilyl ether, and analyzed by gas chromatography-mass spectrometry. A major and a minor component were observed in the analysis of the new compound. The major component had major diagnostic ions indicating the presence of hydroxyl groups at C-12 and C-19. The minor component had major diagnostic ions indicating the presence of hydroxyl groups at C-12 and C-20. The new metabolites are characterized as a mixture of 12S,19- and 12S,20-dihydroxyeicosanoids presumably formed by hydroxylation and reduction of one or more double bonds of 12S-hydroxy-5,8-cis-10-trans-14-cis-eicosatetraenoic acid. These metabolites were formed predominantly with whole spleen lymphocytes but could be detected at longer incubation times or by using 12S-hydroxy-5,8-cis-10-trans-14-cis-eicosatetraenoic acid as the starting substrate with highly enriched B lymphocytes.

12-Hydroxy-5,8,10,14-eicosatetraenoic Acid↗

Capillary-zone electrophoresis/fast-atom bombardment mass spectrometry: design of an on-line coaxial continuous-flow interface.

An on-line coaxial continuous-flow capillary-zone electrophoresis/fast-atom bombardment mass spectrometry (CZE/FAB-MS) interface is described. This interface is shown to be capable of acquiring mass spectra in an on-line fashion from low femtomole amounts of peptides while maintaining high (hundreds of thousands of plates) electrophoretic separation efficiencies. Active electrophoretic transport of the analytes directly to the FAB probe tip obviates the need for a transfer line from the end of the CZE capillary to this point, and thereby precludes the zone broadening that would otherwise occur both within such a transfer line and in the connections between the CZE column and the transfer line. The capability of acquiring an on-line tandem mass spectrometry (MS/MS) spectrum of an electrophoretically separated analyte using this interface is also demonstrated.

Electrophoresis↗