PubMed Health⌕ Search

Biomedical subjects

K Bingham

Publications and source records attributed to K Bingham.

7 recordsLinked to original sources

Clinical evaluation of the Codman microsensor intracranial pressure monitoring system.

INTRODUCTION: The use of the Camino fibre-optic subdural device for measuring Intracranial Pressure (ICP) in patients, has been shown to correlate well with recordings from the "gold standard" intraventricular fluid filled catheter [1]. Following this work, its use has become standard in the clinical monitoring of patients. More recently, laboratory studies have demonstrated accuracy, acceptable drift and high fidelity for the new Codman Microsensor ICP Transducer, a miniature strain gauge mounted on a flexible nylon catheter [3]. Its performance in patients, however, has yet to be fully assessed, in comparative studies. METHODS: Eight patients (5 head injured, 3 with an Intracerebral haematoma) had a Codman Microsensor inserted. A Camino Transducer was fitted immediately adjacent to it. A computerised system was used to continuously record both ICP readings. RESULTS: In total 140,323 recordings were made over a wide range of ICP values. Study periods ranged from 0.5 to 116 hours. In one patient the Codman transducer tracing failed after several days, probably due to fracture of electrical cable close to the interface box. The readings from the two ICP transducers were compared on Time Series, logistic regression and Altman-Bland plots. Drift of the ICP recorded by the Codman microsensor, was noted in 2 patients, 1 in positive direction (maximum 30 mmHg), 1 negative (max. 20 mmHg). In both cases the Camino ICP recording was relatively stable. In 24% of the recordings the Codman microsensor recorded ICP as 5 or more mmHg greater than the Camino, this difference was 10 mmHg or greater in 9% of recordings. Conversely the Camino recording was 5 mmHg or more, than the Codman, in 5% of all recordings, and 10 mmHg or more in 3%. CONCLUSION: These differences could in the majority of cases (excepting the negative drift) be explained by a constant offset of the Codman transducer, as described previously [6]. Further examination of this device is required.

Brain Injuries↗

[The Dufourmentel flap-plasty for treatment of chronic pilonidal sinus].

Thirty-seven patients with chronic sinus pilonidalis were treated after total excision by Dufourmentel flap. We saw seroma complications in three and wound infections in two cases. Patients stayed in hospital 6.3 days on an average and were able to work after 2.5 weeks. The method is easy to use. We have not seen a return to sinus problems in any of this cases.

Abscess↗

Postoperative nausea and vomiting.

Postoperative nausea and vomiting (PONV) is a widespread and often underestimated problem that invariably falls onto the shoulders of nursing staff. In order to find out how nurses view this condition, a major survey was conducted amongst members of the National Association of Theatre Nurses.

Attitude of Health Personnel↗

A comparison of the safety, efficacy, and distribution of ceforanide and cephalothin in coronary artery bypass graft surgery.

Antibiotic prophylaxis in open-heart operations is a widely accepted practice. Introduction of new antibiotics with differences in tissue distribution, spectrum of activity and therapeutic index prompts their evaluation as possible effective prophylactic agents. We compared the distribution, clinical efficacy, and safety of ceforanide with cephalothin as a prophylactic agent in coronary artery bypass graft (CABG) procedures. The results indicated that the intravenous administration of ceforanide at the dose of 1 gm every 12 hours for 2.5 days was equivalent to cephalothin 1 gm every 6 hours for 2.5 days. Serum, muscle, and bone concentrations of ceforanide were significantly greater than those of cephalothin. These concentrations consistently exceeded the minimal inhibitory concentration for Staphylococcus aureus, the major pathogen implicated in wound infections. No toxicty was observed with either antibiotic. Ceforanide merits consideration as a prophylactic antibiotic in CABG operations.

Aged↗

On your bike!

Explore the source record for details and available documents.

Accidents, Traffic↗

Women's health.

Explore the source record for details and available documents.

Adult↗