PubMed Health⌕ Search

Biomedical subjects

K Bliznakova

Publications and source records attributed to K Bliznakova.

5 recordsLinked to original sources

Dual-energy mammography: simulation studies.

This paper presents a mammography simulator and demonstrates its applicability in feasibility studies in dual-energy (DE) subtraction mammography. This mammography simulator is an evolution of a previously presented x-ray imaging simulation system, which has been extended with new functionalities that are specific for DE simulations. The new features include incident exposure and dose calculations, the implementation of a DE subtraction algorithm as well as amendments to the detector and source modelling. The system was then verified by simulating experiments and comparing their results against published data. The simulator was used to carry out a feasibility study of the applicability of DE techniques in mammography, and more precisely to examine whether this modality could result in better visualization and detection of microcalcifications. Investigations were carried out using a 3D breast software phantom of average thickness, monoenergetic and polyenergetic beam spectra and various detector configurations. Dual-shot techniques were simulated. Results showed the advantage of using monoenergetic in comparison with polyenergetic beams. Optimization studies with monochromatic sources were carried out to obtain the optimal low and high incident energies, based on the assessment of the figure of merit of the simulated microcalcifications in the subtracted images. The results of the simulation study with the optimal energies demonstrated that the use of the DE technique can improve visualization and increase detectability, allowing identification of microcalcifications of sizes as small as 200 microm. The quantitative results are also verified by means of a visual inspection of the synthetic images.

Algorithms↗

Simulation studies of field shaping in rotational radiation therapy.

This article presents simulation studies of field shaping in rotational radiation therapy by means of two categories of beam modifying devices: protectors and shapers. The protectors used are diminished copies of the organs at risk (OARs) and stay parallel to them during gantry rotation. Thus, each protector always keeps the corresponding OAR in its shadow, significantly reducing the irradiation. The shapers are used in order to obtain a more uniform dose distribution in the planning target volume (PTV) while preserving their initial orientation during gantry rotation. Thus, the use of beam modifying devices allows modulation of the beam intensity, to better fit irradiation requirements, at every gantry position. A software tool for calculations of geometrical position and dimensions of the beam modifying devices, using information about the shape, size, and position of the protected organ or area at risk as input, was developed. This tool was integrated into the in-house-developed Monte Carlo radiation therapy simulator (MCRTS), used to simulate the particle transport through the designed system. The verification of the software tool showed good agreement between experimental and simulation data, with discrepancies of less than 3%. Dose distributions in solid-geometry and voxel-based neck models were evaluated. Furthermore, the effectiveness of the shapers to modify the dose distribution outside the protected area was studied. Results demonstrated that the use of the shapers effectively improves dose uniformity. Studies using shapers of different materials were also carried out and resulted in similar dose distributions. The results of the simulation studies with a voxel-based model showed that rotational therapy with beam modifying devices offers adequate protection of the OAR and a uniform dose distribution outside the protected region.

Algorithms↗

A three-dimensional breast software phantom for mammography simulation.

This paper presents a methodology for three-dimensional (3D) computer modelling of the breast, using a combination of 3D geometrical primitives and voxel matrices that can be further subjected to simulated x-ray imaging, to produce synthetic mammograms. The breast phantom is a composite model of the breast and includes the breast surface, the duct system and terminal ductal lobular units. Cooper's ligaments, the pectoral muscle, the 3D mammographic background and breast abnormalities. A second analytical x-ray matter interaction modelling module is used to generate synthetic images from monoenergetic fan beams. Mammographic images of various synthesized breast models differing in size, shape and composition were produced. A preliminary qualitative assessment performed by three radiologists and a quantitative evaluation study using fractal and grey-level histogram analysis were conducted. A comparative study of extracted features with published data has also been performed. The evaluation results indicated good correlation of characteristics between synthetic and actual radiographs. Applications foreseen are not only in the area of breast imaging experimentation but also in education and training.

Breast↗

An integrated research tool for X-ray imaging simulation.

This paper presents a software simulation package of the entire X-ray projection radiography process including beam generation, absorber structure and composition, irradiation set up, radiation transport through the absorbing medium, image formation and dose calculation. Phantoms are created as composite objects from geometrical or voxelized primitives and can be subjected to simulated irradiation process. The acquired projection images represent the two-dimensional spatial distribution of the energy absorbed in the detector and are formed at any geometry, taking into account energy spectrum, beam geometry and detector response. This software tool is the evolution of a previously presented system, with new functionalities, user interface and an expanded range of applications. This has been achieved mainly by the use of combinatorial geometry for phantom design and the implementation of a Monte Carlo code for the simulation of the radiation interaction at the absorber and the detector.

Computer Simulation↗

Integrated software system for improving medical equipment management.

The evolution of biomedical technology has led to an extraordinary use of medical devices in health care delivery. During the last decade, clinical engineering departments (CEDs) turned toward computerization and application of specific software systems for medical equipment management in order to improve their services and monitor outcomes. Recently, much emphasis has been given to patient safety. Through its Medical Device Directives, the European Union has required all member nations to use a vigilance system to prevent the reoccurrence of adverse events that could lead to injuries or death of patients or personnel as a result of equipment malfunction or improper use. The World Health Organization also has made this issue a high priority and has prepared a number of actions and recommendations. In the present workplace, a new integrated, Windows-oriented system is proposed, addressing all tasks of CEDs but also offering a global approach to their management needs, including vigilance. The system architecture is based on a star model, consisting of a central core module and peripheral units. Its development has been based on the integration of 3 software modules, each one addressing specific predefined tasks. The main features of this system include equipment acquisition and replacement management, inventory archiving and monitoring, follow up on scheduled maintenance, corrective maintenance, user training, data analysis, and reports. It also incorporates vigilance monitoring and information exchange for adverse events, together with a specific application for quality-control procedures. The system offers clinical engineers the ability to monitor and evaluate the quality and cost-effectiveness of the service provided by means of quality and cost indicators. Particular emphasis has been placed on the use of harmonized standards with regard to medical device nomenclature and classification. The system's practical applications have been demonstrated through a pilot evaluation trial.

Database Management Systems↗