The spatial accuracy of cellular dose estimates obtained from 3D reconstructed serial tissue autoradiographs.

In order to better predict and understand the effects of radiopharmaceuticals used for therapy, it is necessary to determine more accurately the radiation absorbed dose to cells in tissue. Using thin-section autoradiography, the spatial distribution of sources relative to the cells can be obtained from a single section with micrometre resolution. By collecting and analysing serial sections, the 3D microscopic distribution of radionuclide relative to the cellular histology, and therefore the dose rate distribution, can be established. In this paper, a method of 3D reconstruction of serial sections is proposed, and measurements are reported of (i) the accuracy and reproducibility of quantitative autoradiography and (ii) the spatial precision with which tissue features from one section can be related to adjacent sections. Uncertainties in the activity determination for the specimen result from activity losses during tissue processing (4-11%), and the variation of grain count per unit activity between batches of serial sections (6-25%). Correlation of the section activity to grain count densities showed deviations ranging from 6-34%. The spatial alignment uncertainties were assessed using nylon fibre fiduciary markers incorporated into the tissue block, and compared to those for alignment based on internal tissue landmarks. The standard deviation for the variation in nylon fibre fiduciary alignment was measured to be 41 microns cm-1, compared to 69 microns cm-1 when internal tissue histology landmarks were used. In addition, tissue shrinkage during histological processing of up to 10% was observed. The implications of these measured activity and spatial distribution uncertainties upon the estimate of cellular dose rate distribution depends upon the range of the radiation emissions. For long-range beta particles, uncertainties in both the activity and spatial distribution translate linearly to the uncertainty in dose rate of < 15%. For short-range emitters (< 100 microns), such as alpha particle sources, the magnitude of the uncertainty in serial section alignment is comparable with the particle track length. Under these circumstances, dosimetric errors are introduced in proportion to the serial section alignment inaccuracy.

Animals↗

Image analysis for the study of radionuclide distribution in tissue sections.

UNLABELLED: Tissue section autoradiographs are often prepared to review the precise spatial locations of a radiolabeled molecule relative to cells, such as in the study of radiolabeled antibody distribution. The objective of this work was to develop and evaluate a method to automatically detect both grains and cell nuclei from stained tissue autoradiographs using a microscope and an image analyzer. METHOD: Using a sequence of morphological image operations, the densely stained regions of the section, representing the cell nuclei are identified first, and then subtracted from the original image. This enables the identification of autoradiographic grains under conditions of variable contrast, by separation of the grains overlapping the cell nuclei from the extracellular spaces, permitting a more accurate and robust automatic segmentation routine. RESULTS: The accuracy of the method to detect grains has been evaluated at different threshold levels. The highest accuracy obtained was approximately 90%. The accuracy in the detection of cell nuclei was histology-dependent. As examples, we have estimated accuracies of approximately: 86%, 81% and 77% for kidney, EL-4 lymphoma and pneumonocyte sections, respectively. CONCLUSION: This method was tested using specimens designed to study radiolabeled antibody distribution, but it should be applicable with comparable accuracy to other radiolabeled compounds for which quantitative information on the heterogeneity of distribution is required.

Animals↗

Internal dosimetry using data derived from autoradiographs.

Cancer therapies based on administered radionuclides require accurate information on tumor dose. One of the major factors influencing the distribution of absorbed-dose characteristics is the uniformity of the radiolabel distribution in tissue. To study the effect of nonuniformities, we used image analysis techniques to measure automatically the coordinates of autoradiographic grains (sources) and cell nuclei in cut sections from three different tumors, following treatment with radiolabeled antibodies. The spatial distribution data of sources and cell nuclei from these tumor sections were assessed and the pattern of energy deposition in the cell nuclei calculated, assuming that each autoradiograph grain corresponded to a source of the alpha emitter astatine-211 (211At) or the beta emitter yttrium-90 (90Y). The distribution of deposited energy obtained for the real grain distributions was compared to the distribution assuming a locally uniform source distribution, i.e., simulating grain count averaging as produced by a microdensitometric method within a 100 x 100 microns 2 frame size (frame averaging), and a uniform distribution across the entire section (section averaging). The results show first that when the grain distribution is uniform, the average dose within the section is an adequate estimate of the dose to the cell nuclei. Second, when the grain distribution is nonuniform, the distribution of doses to the cell nuclei is significantly less when calculations use the measured grain coordinates, or frame averaging, than when section averaging is used. Third, when the sources are located on or in the cells, both frame and section averaging produce underestimates of the dose to the cell nuclei.

Animals↗

Metabolic responses to ammonium acetate infusion in exercising horses.

The relationship between elevated plasma ammonia (NH3) levels, fatigue development and muscle metabolism were examined in horses during a submaximal fatigue test. Eight Quarter Horse mares were intravenously infused prior to exercise with either sodium acetate (control) or ammonium acetate (AMINF), and exercised to fatigue on an 11% grade treadmill, carrying 27 kg of lead. Time to fatigue was not different (P greater than 0.05) between groups. Intramuscular NH3 and lactate increased (P less than 0.001) during exercise; however, the treatment did not (P greater than 0.05) affect either. A treatment by exercise interaction (P less than 0.01) occurred for plasma NH3. The reciprocal relationship between changes in plasma and intramuscular alanine (ala) and glutamate (glu) indicated activation of the glucose-alanine cycle. Plasma glutamine (gln) increased (P less than 0.001) during exercise; however intramuscular gln was not (P greater than 0.05) altered. The excretion of urea-N was depressed as a result of exercise while the orotic acid/creatinine ratio did not (P greater than 0.05) change. The amino acids and urinary metabolites were not (P greater than 0.05) affected by treatment. These results did not show any metabolic evidence for a role of increased plasma NH3 levels in fatigue development. However this study did provide insight into other aspects of nitrogen metabolism during exercise in the horse.

Acetates↗

Effect of sodium bicarbonate on racing Standardbreds.

Twenty-two Standardbred horses in race training were used in a crossover experiment to determine the effect of oral sodium bicarbonate (NaHCO3) administration on performance and metabolic responses to a 1.6-km (1-mile) race. Horses were paired and one horse in each pair was treated with either NaHCO3 (300 mg/kg BW) or a placebo, 2.5 h before they raced against each other. Each horse was scheduled to compete in two races, approximately 1 wk apart, one on each treatment. Horses always raced in the same pairs. Fourteen horses successfully completed both races. Jugular blood samples were obtained 1.5 h after treatment (rest), immediately before racing, 5 min post-race and 15 min post-race. In six horses, blood samples also were obtained 30 min post-race. Race times averaged 1.1 s faster after NaHCO3 treatment (P less than .1). Sodium bicarbonate treatment also elevated blood pH (P less than .05). In the horses sampled 15 and 30 min post-race, blood lactate disappearance was faster with the NaHCO3 treatment (P less than .05). The NaHCO3 may delay the fatigue precipitated by i.m. acidosis. Because other factors may limit performance (musculoskeletal soundness, cardiovascular and respiratory ability), NaHCO3 would not be expected to enhance the performance of all horses. However, the effect of NaHCO3 on lactate clearance may have implications for all intensively worked horses; because lactate and the associated hydrogen ions are believed to cause muscle damage and soreness, any mechanism to increase their removal rate could benefit the equine athlete.

Acid-Base Equilibrium↗